AC Current Probe

Model JM810A

User Manual

DESCRIPTION

The JM810A (Catalog #2110.80) is designed for use in industrial environments. The 

“squared” jaws permit multiple conductor or bus bar positioning. The current output makes 

it the perfect tool for measurement with DMMs, recorders, and power and harmonic meters. 

The Model JM810A is compatible with any AC ammeter, multimeter, or other current 

measuring instrument with an input impedance lower than 1 Ω. To achieve the stated 

accuracy, use the JM810A with the DMM having an accuracy of 0.75%.

WARNING

 

These safety warnings are provided to ensure the safety of personnel and proper operation of the 

instrument.

 

Read the instruction manual completely and follow all the safety information before attempting to use 

or service this instrument.

 

Use caution on any circuit: high voltages and currents may be present and may pose a shock 

hazard.

 

Read the Safety Specifications section prior to using the current probe. Never exceed the maximum 

voltage ratings given.

 

Safety is the responsibility of the operator.

 

ALWAYS connect the current probe to the display device before clamping the probe onto the sample 

being tested.

 

ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use. Replace any 

defective parts immediately.

 

NEVER use the current probe on electrical conductors rated above 600 V in overvoltage category III 
(CAT III). Use extreme caution when clamping around bare conductors or bus bars.

INTERNATIONAL ELECTRICAL SYMBOLS

 

This symbol signifies that the current probe is protected by double or reinforced  

 

 

 insulation. Use only factory-specified replacement parts when servicing the  

 

 instrument.

 Thi

s symbol signifies CAUTION! and requests that the user refer to the user manual    

 

 before using the instrument.

 

This symbol signifies that this is a type A current sensor and that application near and   

 

 removal from HAZARDOUS LIVE conductors is permitted.

DEFINITION OF MEASUREMENT CATEGORIES
CAT IV: 

For measurements performed at the primary electrical supply (<1000 V), such as    

 

primary overcurrent protection devices, ripple control units, or meters.

CAT III: 

For measurements performed in the building installation at the distribution level,    

 

such as hardwired equipment in fixed installation or circuit breakers.

CAT II: 

For measurements performed on circuits directly connected to the electrical  

 

 

distribution system, such as household appliances or portable tools.

RECEIVING YOUR SHIPMENT

Upon receiving your shipment, make sure that the contents are consistent with the packing 

list. Notify your distributor of any missing items. If the equipment appears to be damaged, 

file a claim immediately with the carrier and notify your distributor at once with a detailed 

description of any damage.