Power Quality Analyzer Model 8335
5.2.3 Apparent Power
The
VA
sub-menu displays the harmonics of the apparent power.
5.2.3.1 Apparent Power Harmonics Display Screen (3L)
3
1
2
Figure 5-15
Item
Function
1
Harmonic selection cursor; change values with the cursor using the
◄
and
►
buttons
2
The horizontal axis indicates the orders of the harmonics (odd marking). Display of the
level of the harmonics as a percentage of the fundamental (order 1)
- DC:
DC component
- 1 to 25:
harmonics of order 1 to 25; when the cursor exceeds order 25, order 26 to 50
appears
3
- Vah 03:
harmonic number
- %:
ratio of the harmonic to the fundamental
-
+000°:
phase shift of the voltage harmonic with respect to the current harmonic for
the order in question
: Indicator of energy generated for this harmonic
: Indicator of energy consumed for this harmonic