background image

n

 

COMPATIBLE CURRENT  

 

PROBES & SENSORS FOR 

 

POWER QUALITY METERS

193-24-BK

193-36-BK

A196-24-BK

MA193-10-BK

MA193-14-BK

J93

MN93-BK

MN193-BK

MR193-BK

SL261-BK

SR193-BK

E N G L I S H

User Manual

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Содержание 193-24-BK

Страница 1: ...ES SENSORS FOR POWER QUALITY METERS 193 24 BK 193 36 BK A196 24 BK MA193 10 BK MA193 14 BK J93 MN93 BK MN193 BK MR193 BK SL261 BK SR193 BK E N G L I S H User Manual www calcert com sales calcert 8 610...

Страница 2: ...express implied or otherwise Chauvin Arnoux Inc has made every reasonable effort to ensure that this documentation is accurate but does not warrant the accuracy or completeness of the text graphics o...

Страница 3: ...fully understand Useful information or tip to read The CE marking guarantees conformity with European directives and with regulations covering EMC The trash can with a line through it means that in t...

Страница 4: ...ude degree of pollution location Do not use the current probe if its housing is open deteriorated or incorrectly reassembled Before each use check the integrity of the insulation of the unit jaws clam...

Страница 5: ...7 2 1 4 AC Current Probe Models MN93 BK MN193 BK 8 2 1 5 AC Current Probe Model MR193 BK 9 2 1 6 AC Current Probe Model SL261 10 2 1 7 AC Current Probe Model SR193 BK 11 3 OPERATION 12 4 SPECIFICATIO...

Страница 6: ...probes in this manual are compatible only with AEMC Power Analyzers see 4 for meter compatibility AmpFlex Sensor 24 Model 193 24 BK Cat 2140 34 AmpFlex Sensor 36 Model 193 36 BK Cat 2140 35 AmpFlex Se...

Страница 7: ...2 PRODUCT FEATURES 2 1 Control Features 2 1 1 AmpFlex Models 193 24 BK 193 36 BK 196 24 BK 2 3 4 1 1 Flexible sensor 2 Sensor opening connector 3 Shielded lead 4 Custom 4 pin input connector www calce...

Страница 8: ...ensors for Power Quality Meters 2 1 2 MiniFlex Model MA193 BK 2 3 4 1 1 Flexible sensor 2 Sensor opening device 3 Shielded lead 4 Custom 4 pin input connector www calcert com sales calcert 8 610 7664...

Страница 9: ...4 5 6 3 5000A 500A ZERO Stop Test MARCHE SORTIE ZERO ON OFF 300VCA TIV 600VCA TIII 1 Jaws 2 4 point CA connector 3 Safety guard 4 Zero adjustment knob 5 Power ON Low battery indicator 6 Three positio...

Страница 10: ...t Probe Models MN93 BK MN193 BK 200V CAT IV 600V CAT III 200A 5 4 2 3 6 1 1 Jaws 2 Protective guard 3 Two position range switch MN193 only 4 Jaw opening lever 5 Shielded lead 6 Custom 4 pin input conn...

Страница 11: ...2 1 5 AC Current Probe Model MR193 BK 5 2 4 3 7 6 1 1 Jaws 2 Protective guard 3 Jaw opening lever 4 Two position range switch 5 Shielded lead 6 Zero adjustment 7 Custom 4 pin input connector www calce...

Страница 12: ...1 6 AC Current Probe Model SL261 2 3 5 6 4 1 1 Jaws 2 Zero adjust knob 3 Range selection switch 4 Battery compartment screw 5 Battery compartment cover 6 BNC Adapter sold separately Cat 2140 40 www ca...

Страница 13: ...Power Quality Meters 11 2 1 7 AC Current Probe Model SR193 BK 4 2 3 5 1 1 Jaws 2 Protective guard 3 Jaw opening lever 4 Shielded lead 5 Custom 4 pin input connector www calcert com sales calcert 8 61...

Страница 14: ...current input to match the phase identifiers on the measured system IMPORTANT NOTE Always connect the probes or sensors with the indicating arrows pointing toward the load For Example Only instrument...

Страница 15: ...sides of the opening connector MiniFlex Press the opening device to open the flexible sensor Clamp the sensor around the conductor to be tested For best results center the conductor in the jaws of the...

Страница 16: ...10 000A peak 8333 8336 PEL Series MiniFlex MA193 1 14 355 mm 200mA to 3000A 10 000A peak 8333 8336 PEL Series J93 50 to 3500 50 to 5000 DC only 8333 8336 8435 and PEL MN93 2 to 240AAC I 200A not perma...

Страница 17: ...x 158 x 25mm 7 7 oz 270g MiniFlex MA193 10 BK 10 250mm 10 ft 3m 2 75 70mm 4 0 x 2 5 x 1 1 103 x 64 x 28mm 1 94 oz 55g MiniFlex MA193 14 BK 14 350mm 10 ft 3m 3 94 100mm 4 0 x 2 5 x 1 1 103 x 64 x 28mm...

Страница 18: ...According to IEC 61010 1 Electrical safety according to IEC 61010 2 032 Maximum applicable voltage AmpFlex 1000V CAT III 600V CAT IV MiniFlex 1000V CAT III 600V CAT IV J93 600V CAT III 300V CAT IV MN...

Страница 19: ...acement 5 2 1 Model MR193 Disconnect the MR193 completely and turn the rotary switch to OFF Use a screwdriver to unscrew the screws and remove the battery compartment cover on the backside of the unit...

Страница 20: ...e it completely by hand Remove the battery and the shim from the compartment Place the new battery in the compartment with the polarity as indicated on the label Then replace the shim Put the battery...

Страница 21: ...www calcert com sales calcert 8 610 7664 0 5 10 15 20 25 30...

Страница 22: ...repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material 5 6 Warranty Repairs What you m...

Страница 23: ...www calcert com sales calcert 8 610 7664 0 5 10 15 20 25 30...

Страница 24: ...12 15 99 MAN 100391 v4 Chauvin Arnoux Inc d b a AEMC Instruments www calcert com sales calcert 8 610 7664 0 5 10 15 20 25 30...