CA7027
FAULT MAPPER PRO
®
GRAPHICAL TDR
E N G L I S H
User Manual
www.
GlobalTestSupply
.com
Find Quality Products Online at:
[email protected]
All manuals and user guides at all-guides.com
all-guides.com
Страница 1: ...ULT MAPPER PRO GRAPHICAL TDR E N G L I S H User Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com All manuals and user guides at all guides com a l l g u i d e...
Страница 2: ...ications The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer Serial _________________________________ Catalog 2127 84 Model CA7027 P...
Страница 3: ...Getting Started 9 4 4 Set up Mode 9 4 5 Backlight 10 4 6 Tone Generator 10 4 7 Selecting Full Scale Sensitivity 11 4 8 Adjusting the Vp Value 11 4 9 Determining and Measuring Vp Values 11 4 10 Attach...
Страница 4: ...y double or reinforced insulation CAUTION Risk of Danger Indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument in all cases where thi...
Страница 5: ...he damaged packing container to substantiate your claim 1 3 Ordering Information Fault Mapper Pro Model CA7027 Cat 2127 84 Includes carrying case 4mm color coded banana plugs with alligator clips 4x1...
Страница 6: ...trs micro second this value will vary according to the type of cable under test The Fault Mapper Pro can accept user selectable values between 1 and 99 or the equivalent value in feet or meters per mi...
Страница 7: ...Red Black 2 Graphical LCD 3 Cable select and Vp Velocity of Propagation decrement button 4 Test function select button 5 Backlight button 6 Cable select and Vp Velocity of Propagation increment button...
Страница 8: ...table 1 2 3 5 minutes or disabled MECHANICAL Dimensions 6 5 x 3 5 x 1 5 165 x 90 x 37mm Weight with battery 12oz 350g Display Resolution 128 x 64 pixel Graphical LCD Display Backlight Electroluminesce...
Страница 9: ...ength If the Vp is set incorrectly by the operator or the Vp varies along the length of the cable then additional errors will be incurred and the measurement accuracy will be affected NOTE The Vp is l...
Страница 10: ...ct value of Vp being used for the cable under test and homogeneity of the Vp along the cable length If the Vp is set incorrectly by the operator or the Vp varies along the length of the cable then add...
Страница 11: ...tdown 1 Minute 2 The following options can be configured TDR or Tone Generation Set Vp to 1 to 99 or speed in micro seconds see 4 8 Set cable impedance Z to 25 50 75 or 100 Twisted pair T P Set measur...
Страница 12: ...is switched on and off with the button 4 6 Tone Generator The Fault Mapper Pro may also be used as a tone generator to trace and identify cables and wires The user will need a cable tone tracer such a...
Страница 13: ...use the and buttons to adjust the Vp to scroll between v 2 M Ms or Vp UC Press the TDR button to exit the set up mode 4 9 Determining and Measuring Vp Values Vp or Velocity of Propagation values are c...
Страница 14: ...the Fault Mapper Pro to one end of the cable to be tested The cable attachment is via a banana plug input located at the top of the unit For unterminated cables use the alligator clip attachment prov...
Страница 15: ...f the trace by pressing the and buttons To determine the distance to an event position the cursor at the beginning of the event and read off the distance as shown below Vp 72 Z 100 413ft On the fault...
Страница 16: ...Continuous Scanning mode is active Continuous Scanning Mode Fires pulses into the cable under test at the rate of 6 7 pulses per second In this mode the Fault Mapper Pro is able to more easily identi...
Страница 17: ...tteries with 4 x 1 5V AA alkaline batteries observing the polarities 4 Reattach the battery compartment cover 5 2 Cleaning Disconnect the instrument from any source of electricity Use a soft cloth lig...
Страница 18: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com All manuals and user guides at all guides com...
Страница 19: ...we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an...
Страница 20: ...01 12 99 MAN 100361 v2 Chauvin Arnoux Inc d b a AEMC Instruments www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com All manuals and user guides at all guides com...