NOTE:
1) Momentary Contact
-- The Egress Delay starts to count when the egress button is momentarily
2)
3)
The Egress Delay does not affect the operation of the User Codes/Cards for Output 1. The User
(4) VALIDATION
Press
key once. Two-beep confirms the entry
EXAMPLES:
Example 1
: Set Egress Button in Momentary contact of 5 seconds with delay & warning beep
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Momentary contact with warning,
(c)
Delay time of 5 seconds
to release door, (d) Entry confirmation
Example 2:
Set Egress Button in Holding contact of 10 seconds with warning beep
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Holding contact mode with warning,
(c)
Holding time of 10
seconds to release door, (d) Entry confirmation
Example 3
: Set Egress Button in Momentary contact without delay (This is the default setting)
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Momentary contact without delay,
(c)
Release door instantly,
(d)
Entry confirmation
pressed. Output 1 activates automatically (door is released) when the delay time reaches.
Code
s/Cards always give
INSTANT
action.
COMMON USER CODES FOR OUTPUT 1 & 2 (Locations 03 & 04)
The Common User Codes 1 and 2 are prepared for operating Output 1 and 2 respectively as an
enhance code. The Common User Codes
MUST
work in the form of “Card + Common Code” to
operate the outputs to increase the security of the access control system. See Media 4 at Locations 10
& 20 for more information.
NOTE:
Common User Code alone can
NOT
operate the Outputs directly.
LOCATIONS COMMON USER CODE VALIDATION
(1) LOCATIONS
-- Location Stores The Common User Code for Output 1
-- Location Stores The Common User Code for Output 2 (DK-2891A only)
(2) COMMON USER CODES
The Common User Code can be 4 to 8 digits.
When a new Common User Code is keyed in and confirmed, the old one is replaced.
(3) VALIDATION
Pressing
key to confirm code entry.
Example:
a) Set a Common User Code “1 3 5 7” for Output 1 ----
b) Deleted a Common User Code from memory: Key in the Location number and #. ----
4 to 8 Digits
-
(1)
(2)
(3)
Holding Contact
-- The user
MUST
hold the egress button in contact for the whole period of the
Egress Delay time until Output 1 activates. If the egress button is released before the end of the
Egress Delay, the timer will stop to count and reset.
For safety, it is necessary to put
a sticker next to the egress button
telling how to open the
door if “Holding Contact” is enabled.
Example: A sticker for an egress button that is programmed with “Holding Contact” of 5 seconds.
Press & Hold The Button
5 Seconds Minimum
Until The Door Is Open