5.
Clean the dispenser recess with a
brush.
6.
Put back the dispenser in the recess.
11.6
Drain pump
The pump should be inspected regularly
and particularly if:
• the appliance does not empty and/or
spin;
• the appliance makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump;
• a problem with water draining is de-
tected (see chapter “Troubleshoot-
ing” for more details).
WARNING!
Before unscrewing the pump
cover, switch the appliance off
and remove the mains plug from
the socket.
Proceed as follows:
1.
Unplug the appliance.
2.
If it is necessary, wait until the water
has cooled down.
A
B
3.
Place a container close to the pump
to collect any spillage.
4.
Release the emergency emptying
hose (
B
), place it in the container
and remove its cap cover.
5.
When no more water comes out,
unscrew the pump cover (
A
) by turn-
ing it anti-clockwise and remove the
filter. Use pliers, if necessary.
Always keep a rag nearby to dry up
any water spillages when removing
the cover. Clean the filter under a
tap, to remove any traces of fluff.