• Disconnect the appliance from the
mains supply.
• Cut off the mains electrical cable
close to the appliance and dispose of
it.
3. INSTALLATION
WARNING!
Refer to Safety chapters.
3.1 Before the installation
Before you install the hob, write down the
information below from the rating plate.
The rating plate is on the bottom of the
hob.
Serial number ...........................
3.2 Built-in hobs
Only use the built-in hobs after you
assemble the hob into correct built-in
units and work surfaces that align to the
standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• To replace the damaged mains cable,
use the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. The single wire must have a
diameter of minimum 1,5 mm². Speak
to your local Service Centre. The
connection cable may only be
replaced by a qualified electrician.
WARNING!
All electrical connections
must be made by a qualified
electrician.
CAUTION!
Connections via contact
plugs are forbidden.
CAUTION!
Do not drill or solder the wire
ends. It is forbidden.
CAUTION!
Do not connect the cable
without cable end sleeve.
One-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Merge the black and brown cable
ends.
4. Apply a new wire end sleeve on the
common cable end (special tool
required).
Cable cross section 2x1,5 mm²
N
L1
N
L
220-240 V~
400V 2~N
L2
One-phase connection - 220 - 240 V~
Two-phase connection - 400 V 2 ~ N
Green - yellow
Green - yellow
N
Blue and blue
Blue and blue
N
L
Black and brown
Black
L1
Brown
L2
ENGLISH
7
Содержание IKK86683FB
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ...www aeg com shop 867366350 A 152021 ...