A
B
A) supplied seal
B) supplied brackets
10.
11.
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.9
Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door or drawer
min 6 mm
min 30 mm
60 mm
b
a
min 5 mm
(max 150 mm)
A.
Removable panel
B.
Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9.
TECHNICAL DATA
9.1
Hob dimensions
Width
894 mm
Depth
510 mm
9.2
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Triple Crown
56
Rapid
42
ENGLISH
17