
72
Outlet hole - Only for models DF 6260, DF 6260-ml/1
and CHDF 6260
(extractor-filter version)
• When used as an extractor unit, the hood
must be fitted with a 150mm diameter
hose.
Only for model DF 6260 - DF 6260-ml/1:
Should there already be a pipe of
diameter 125 mm that ducts to the
outside through the walls or roof, it is
possible to use the 150/125 mm reduction
flange provided. In this case the hood will
be slightly more noisy.
Fix the flange on the hood outlet hole,
using 2 screws.
Fig. 8a
.
Filter version only
•
Fix the deflector to the flange.
Fig. 8b
.
Outlet hole - Only for model DF 6160(extractor-filter version)
• When used as an extractor unit, the hood must be fitted with a
120mm diameter hose.
• The dimensions and position of the air outlet are given in figure 9.
• Using the adapter, Ø100, Ø110 and Ø125 mm exhausting pipes can
be used.
Ø 125 mm exhausting hose:
insert the adapter on the flange and
remove, using a proper tool, the upper unused Ø 100 and Ø 110 mm
rings of the adapter.
Ø 110 mm exhausting pipe:
same procedure, but removing
the Ø 100 mm ring only.
Ø 100 mm exhausting pipe:
apply the adapter on the flange.
Fig. 8a
Fig. 8b
Fig. 9
Fig. 10
A