--------------------------------------------------------------------------------29/50--------------------------------------------------------------------------------
Input format ISO 15693 one block:
RD
<SP>
parameter 2
<CR>
Input format ISO 15693 multiple blocks:
RD
<SP>
parameter 2
<SP>
parameter 3
<CR>
Output:
parameter 4
<CR>
Parameters:
PARAMETER 1
FUNCTION
1 or 2 characters
sector
PARAMETER 2
FUNCTION
1 or 2 characters
block/start block
PARAMETER 3
FUNCTION
1 or 2 characters
end block
PARAMETER 4
FUNCTION
32 characters
data (mifare 1K/4K)
8 characters
data (ultralight)
up to 64 charac-
ters
data (ISO 15693)
5.4.6
RDM – read page manual
With the command RDM you can read out a page of the transponder. The reading command is executed
single. You have to do a get tag first. If you are using a mifare standard 1K/4K you have to log in, too.
Input format mifare 1K/4K:
RD
<SP>
parameter 1
<SP>
parameter 2
<CR>
Input format ultralight:
RD
<SP>
parameter 2
<CR>
Input format ISO 15693:
RD
<SP>
parameter 2
<CR>
Input format ISO 15693 multiple blocks:
RD
<SP>
parameter 2
<SP>
parameter 3
<CR>
Output:
parameter 4
<CR>