background image

 

 

 

 

 

 

 

 
 
 

ARE K1 / RS232 

Transponderreader for trovanTM  

transponders for Industrial Applications 

 
 
 
 
 
 
 

Содержание ARE K1 / RS232

Страница 1: ...ARE K1 RS232 Transponderreader for trovanTM transponders for Industrial Applications ...

Страница 2: ...s of the digital inputs 6 2 5 Connection characteristics of the relay outputs 6 2 6 Pin configuration of the RS 232 interface 6 2 7 Antenna cable 6 2 8 Pin Configuration of the terminal blocks for antenna power lines etc 8 2 9 DIP Switches 8 2 10 LED s 8 3 FIRMWARE 9 4 PUTTING INTO OPERATION 10 4 1 Putting into operation for the first time 10 4 2 Trouble shooting 10 5 ANTENNAS 11 6 WARNINGS AND CA...

Страница 3: ... 3 13 8 NOTIFICATION OF CHANGES 13 ...

Страница 4: ...kilift management etc Typical reading range is between 20 cm to 70 cm depending on the type of antenna and transponder 2 Technical data 2 1 Mechanical characteristics The scanner is integrated into a alloy housing with PG threads for the cable connection When assembled cor rectly the housing is good for wet environment according to IP 65 The cable connection is done at the inside of the housing wi...

Страница 5: ... 5 13 2 2 Outline dimensions ...

Страница 6: ... 6 Pin configuration of the RS 232 interface Using the 9 pin Sub D connector i e for PC make the following connections pin 1 of X3 with housing of sub D connector shielding pin 2 of X3 with pin 5 of sub D connector ground pin 3 of X3 with pin 2 of sub D connector transmitter line of the reader pin 4 of X3 with pin 3 of sub D connector receiver line of the reader Interface parameters 19200 baud 8N1...

Страница 7: ...data sync ground 12V break contact of relay QN1 1 2 1 2 24V ground LED1 antenna LED2 no read LED3 read LED4 dig input LED5 error LED6 power LED7 RxD LED8 TxD LED9 not used relay QN1 make contact of relay QR1 relay QR1 break contact of relay QR1 digital input digital input On 1 2 3 4 5 6 7 8 DIP Switch TP4 JP5 JP1 JP2 JP3 JP4 12V GND 3 4 1 2 ...

Страница 8: ... of these LED s are LED 1 on when antenna is operated LED 2 on when last read was not successful LED 3 on when last read was a success LED 4 on as long as the digital input is high LED 5 on when a hardware error was detected LED 6 flashing as long as the reader is powered and the microprocessor is working properly LED 7 on as long as commands were received on the RS 232 interface LED 8 on as long ...

Страница 9: ...S Output of all parameter values List of parameters yes VSAVE store current configuration ok yes The parameters which can be modified are com mand code function universally defined pa rameters ASB 1 0 valid parame ter values for ARE K1 default values MD mode of operation 0 2 0 2 2 triggered by interface BD baud rate 0 3 0 3 2 19200baud EC echo 0 1 0 1 0 off CN suppression of NoRead 0 1 0 2 0 outpu...

Страница 10: ...work in normal condition Attention All set tings are temporary This means they are lost after switching of the reader Make the setting permanent using the command VSAVE c Is the antenna defect or not properly connected In that case LED 2 is not on although the reader is in read mode d The transponder is not in the active antenna field Bring the transponder closer to the antenna e Antenna mounting ...

Страница 11: ...lease check if special permissions are required at the place of opera tion This reader is an active electrical transmission system and radiates in the frequency range of approximately 124 kHz When connecting a defect or a not suited antenna to the device the radiated power can be higher than 42dBµA m measured at 10 m distance The operator is responsible that people at risk are not end agered by th...

Страница 12: ... 15 105 a This equipment has been tested and found to comply with the limits for a Class A digital de vice pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accord...

Страница 13: ...EG Idenfikationssysteme GmbH Hörvelsinger Weg 47 D 89081 Ulm Tel 0049 0 731 140088 0 Fax 0049 0 731 140088 9000 e mail sales aegid de www aegid de 8 notification of changes change no date description of change version editor 10 01 08 22 01 connection of serial interface operating mode ex work now MD2 supplemetation commands ALGO and PM 06 10 08 10 Format 07 05 18 16 FCC Information 08 06 22 16 FCC...

Отзывы: