www.aecosensors.com
YSM NNNNNN
SMC-12 NO AGD3
YSM000014
SMC-12 NO LC5 AGD3
YSM000015
SMC-12 NO LC10 AGD3
YSM000016
FM012EX Rev. B
SMC-12 NO
AGD
LC10
3
LC5
ETC000469
SMC-12 NO
AGD3
■
mm
mm
V
A
W/VA
Hz
°C
IP
> 4
NO
230
0.5
50
230
-25 ÷ +70
67
2 x 0.25mm² PVC
NO
50
CH17
M12x1
BLUE
BROWN
Sensing distance (Sn)
Hysteresis (’’H’’)
Max switching voltage
Ambient temperature range
IP rating
Housing material
Cable
Output type
Max switching current
Max switching power
Max switching frequency
> 20 with M20 magnet
Nichelled Brass
2mt, 5mt or 10mt
WIRING DIAGRAM
Characteristics
Models
Dimensions ‘’mm’’
4. Electrical and Mechanical Characteristics
( Description )
( Code )
3.3 Product series
The magnetic sensors
series includes the models
listed below :
SMC-12 NO
AGD3
■
Potentially explosive atmosphere
with GAS and/or DUST.
Cable length "2mt".
Cable length "5mt".
Cable length "10mt".
Equipment category "3"
according to 2014/34/EU Directive.
Magnetic Sensor with cylindrical enclosure
"M12x1" and "NORMALLY OPEN" output
3.2 Description diagram
3.1 Code diagram
Magnetic sensor intended for use in the explosive atmospheres
according to 2014/34/EU ATEX Directive .
Progressive number
3. Sensor identification
The
series is only identified by the ''
''
and ''
''. The diagrams for the decoding are shown below.
Code
Description
SMC-12 NO
AGD3
■
1. Introduction
This manual should be read and understood in all its parts before proceeding
with installation of the sensor.
The Magnetic Sensors
series, are intended to be
used in a potentially explosive atmospheres with presence of GAS and/or
DUST. They are designed and produced according to the requirements of the
following standards:
SMC-12 NO
AGD3
■
2. Installation and Startup
The sensor must be installed, connected and activated only by specialized
personnel. Personnel must be familiar with the types of protection anti-ignition,
the production rules and regulations in the potentially explosive area. The user
is solely responsible for the choice and the use of sensor suitable to the final
application. When installing the sensor observe the following requirements:
Check whether the classification of the sensor is suitable for the application
(see‘’ATEX Marking’’ to paragraph 5 and marking on the equipment).
Make sure that the connection cable of the sensor does not have the
endings too tight. Moreover it must not prevent the movement of people
and/or things.
Do not touch uninsulated parts of the connecting cable of the sensor before
having it disconnected from the supply voltage. Do not install the sensor
during a thunderstorm with lightning.
If the cable is subject to movement, do not place the sheath with bending
radius too short; Pay attention to the mounting of the parties subject to
movement and to the fixed ones.
Separate the power cables from the connecting cable of the sensor.
Make sure that the sensor housing is always ground wired.
Operating Instructions
GB
According to:
Annex VIII group II, equipment category
3G/3D
Directive 2014/34/EU ( ATEX )
Protect the sensor cable according to EN 60079-14 standard.
The electrical and mechanical characteristics of this series are shown in Table 1:
Tab. 1 - Electrical and Mechanical Characteristics
* EN60079-0:2012 + A11:2013 - Explosive atmospheres-Part 0 : Equipment.
General requirements.
* EN60079-18:2015 - Explosive atmospheres - Part 18: Equipment protection
by encapsulation ‘’m’’.