![AE Techron T3700 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/ae-techron/t3700/t3700_instruction-sheet_2859452001.webp)
T3700 Transformer Instructions
page 1
Information subject to change.
97-8002538 - 8-31-2020
www.aetechron.com
T3700 Transformer
for Electric-Field
Susceptibility Testing
Application
The AE Techron T3700 Electric-Field
Susceptibility Transformer was designed
to meet or exceed the voltage require-
ments of DO 160 Section 19 and Boeing
D6-16050-5 Section 7.2 testing.
It may also be used as a 1-to-37 step-
up transformer for voltages up to 3700
V
RMS
.
Description
The T3700 transformer is able to gen-
erate up to a 3700 V
RMS
potential. It is
withstand tested to 135% of rated output
to ensure a long, trouble-free life. The
turns ratio provides a 1-to-37 step up to
the secondary winding.
The T3700 provides convenient input
connectors via touch-proof,four-way
binding posts. Standard 0.75-inch
spacing of binding posts allows use of
standard plugs.
A 1-amp fuse protects the unit against
over-current conditions. A rugged,
Features
• Up to 3,700 V
RMS
• Meets or exceeds voltage require-
ments of DO 160 Section 19 and
Boeing D6-16050-5 Section 7.2
• Robust design, withstand tested to
5,000 VDC
• Durable steel and high-density poly-
ethylene case for impact resistance
impact-resistant case and robust design
protects the transformer from accidental
damage.
The T3700’s voltage output meets or
exceeds the requirements of DO 160
Section 19 and Boeing D6-16050-5 Sec-
tion 7.2. It is safe for use by experienced
staff.
Unit Setup
Safety First
Throughout these instructions, special
emphasis is placed on good safety
practices. The LIGHTNING FLASH
and EXCLAIMATION POINT graphics
are used to highlight certain topics that
require extra precaution.
Watch for These Symbols:
The lightning flash with the
arrowhead symbol within an
equilateral triangle is intended to
alert the user to the presence of “danger-
ous voltage” inside the product that may
constitute a risk of electric shock.
— INSTRUCTION SHEET —