background image

 
 
 

LVC5050RLY  

Supplement 

 

 
 
 
 

Table of Contents 

 

Pre-Installation................................................... 2 
Safety Conventions ............................................ 2 
General Description ........................................... 3 
Installation ......................................................... 4 
Operation ........................................................... 5 
Specifications..................................................... 6 

Содержание LVC5050RLY

Страница 1: ...LVC5050RLY Supplement Table of Contents Pre Installation 2 Safety Conventions 2 General Description 3 Installation 4 Operation 5 Specifications 6 ...

Страница 2: ...l progress may result in minor variations between this manual and a particular unit Any significant changes or customizations will be reflected in revisions of this manual Customers are encouraged to promptly add any additional information about their particular unit to this manual Safety Conventions The LVC 5050RLY amplifier is a highly sophisticated instrument Special hazard alert instructions a...

Страница 3: ...w harmonic and intermodulation distortion and low noise The features of the LVC5050RLY are the same as the standard LVC5050 amplifier with the following exceptions Output Block Loads connect to a high current output block Its connectors use high current binding posts Output Block Cover No detachable cover is provided for the LVC5050RLY output block See page 4 of the LVC5050 Quick Start Guide for f...

Страница 4: ...ition To activate Parallel Mono mode 1 Turn off the amplifier 2 Wait at least 10 seconds 3 Slide the Dual Mono switch to the left as you face the back panel 4 Connect the input signal to channel 1 and do not use the channel 2 input Both outputs will now receive the signal from the channel 1 input NOTE The channel 2 input and level control are disconnected in Parallel Mono mode A signal feeding cha...

Страница 5: ...050 Quick Start Guide for detailed information on the LVC5050RLY front and back panel functions Output Connectors The LVC5050RLY back panel features a high current output block as shown below Connections are made via high current binding posts Page 5 ...

Страница 6: ...Phase Delay 0 4 at 60 Hz Amplifier to Amplifier Phase Error 0 1 at 60Hz Signal to Noise Ratio At gain of 20 better than 105 dB A weighted below full output Total Harmonic Distortion THD 0 05 from 20 Hz to 1 kHz increasing linearly to 0 1 at 10 kHz at full output Residual Noise 20Hz to 1kHz 0 8mAmp Load Impedance Rated for use into 2 ohms or less Safe with all types of loads even reactive ones Requ...

Страница 7: ... voltage under ODEP conditions Indicators Amber Enable Indicator shows on off status of low voltage power supply A Green OVERLOAD indicator for each channel flashes dim green to show a signal is present at the input and flashes brightly in the rare event distortion of any kind exceeds 0 05 including input overload A bi color Green Red ILOAD ILIMIT indicator for each channel flashes green with the ...

Страница 8: ...gned flow through front to rear ventilation system with computer controlled forced air cooling Dimensions 19 inch 48 3 cm wide 5 25 inch 13 3 cm high 16 inch 40 3 cm deep behind front mounting surface and 2 875 inches 7 3 cm in front of the mounting surface NOTE Allow 4 inches in back for adequate airflow Weight 77 lbs 35 2 kg net 88 lbs 40 2 kg shipping weight Mounting Standard EIA 310 front pane...

Отзывы: