97-7796264_09-04-2020
Information subject to change
35
7548/7794/7796/7796HC OPERATOR’S MANUAL – SECTION 7
Shut off the signal source before reset
-
ting the amplifier. Try resetting the Fault
condition only once. If the Fault condi-
tion does not clear after one reset, STOP.
Contact AE Techron Support for further
assistance. Repeated resetting can dam-
age the amplifier.
CAUTION
7.7.4 Resetting After OverTemp
To reset the amplifier after an OverTemp has oc
-
curred, make sure fans are running, then remove
the input signal from the amplifier. Allow the fans to
run for five minutes, and then push the Reset but
-
ton to reset the amplifier.
7.8 Fault LED is Illuminated
The 7548/7794/7796/7796HC contains protec
-
tion circuitry that disables the amplifier if an output
stage is behaving abnormally. This usually indi
-
cates an output transistor has shorted.
To clear the Fault condition, follow these steps:
1.
Turn off the signal source.
2.
Turn off the AC mains.
3.
Turn AC mains power back on. If the Fault LED
doesn’t illuminate again, turn the signal source
on.
4.
If the Fault LED is still illuminated and the Fault
condition doesn’t clear, return the amplifier for
Factory Service. Please see the Factory Ser-
vice information at the end of this section.
7.9 Factory Service
If the troubleshooting procedures are unsuccess
-
ful, the amplifier may need to be returned for
Factory Service. All units under warranty will be
serviced free of charge (customer is responsible
for one-way shipping charges as well as any cus
-
tom fees, duties, and/or taxes). Please review the
Warranty at the beginning of this manual for more
information.
All service units must be given Return Authoriza
-
tion by AE Techron, Inc. before being returned.
Return Authorizations can be requested on our
website or by contacting our Customer Service
Department.
Please take extra care when packaging your am
-
plifier for repair. It should be returned in its original
packaging or a suitable alternative. Replacement
packaging materials can be purchased for a nomi
-
nal fee.
Please send all service units to the following ad
-
dress and be sure to include your Return Authori-
zation Number on the box.
AE Techron, Inc.
Attn: Service Department / RMA#
2507 Warren Street
Elkhart, IN 46516
Содержание 7548
Страница 2: ......