R3765/67G Series Network Analyzer Operation Manual
7.15 Hard Copy
7-156
If EOI signal is set to ON (enable) and EOI terminal receives “L” when using FP-GL-II,
the plotter operates in the same manner as the terminator.
When the plotter sends data, EOI terminal is set to “L” at the same time as it outputs
the last “LF” code of sending data.
If the reduced drawing mode is selected when using FP-GL-II, the plotter outputs the
drawing being reduced to 0.9 time, based on the global origin.
Then, the actual size of the valid drawing range is not changed and the range to be
specified by the program is extended.
7.15.5 Printer Setup
Setting a printer.
Operation procedure
Press [COPY] to call the copy menu.
Press {PRINT/PLOT SETUPS} to call the setup menu.
Setup menu
{PRINTER SETUP}
: Calls the printer setup menu. (See step
.)
{PRINT SPEED FAST/SLOW}
: Sets the print mode to FAST or SLOW. To set other
parameters, use the printer setup menu (
).
{PLOT LABEL ON/OFF} : See section 7.15.4. (This menu is for the printer. This
menu is not used at printer setup.)
{PLOT P.TXT ON/OFF} : See section 7.15.4. (This menu is for the printer. This
menu is not used at printer setup.)
Table 7-4 DSW2 Function
SW No.
Functions
(ON = 1)
Standards
1 to 5
Plotter addresssetup: Defines the device address with all bits.
SW1 = 1
SW2 = 1
SW3 = 1
SW4 = 1
SW5 = 1
6
Selection of EOI signal control
0 : EOI disabled
1 : EOI enabled
However, available only when using FP-GL-II. Not defined for FP-
GL-I.
0
7
Not defined
0
8
Selection of reduced drawing mode (only when using FP-GL-II).
1 : Selects reduced drawing mode (0.9 time)
0
Bit structure
Address 31 is for listen only mode.
SW5
SW4
SW3
SW2
SW1
1
2
3
4
4