Advantech SSPB-3000C Скачать руководство пользователя страница 27

 

SSBP-3000C

 

Page  26

 

1.  Using the proper mounting hardware and the non-pivoting slide kit (see 

TABLE  20

 at page 

46), install the SSPB on to the rack with the waveguide output facing the rear. 

2.  For a pressurised waveguide system install a pressure window at the RF output port of the 

SSPB. 

3.  Attach a waveguide gasket (see 

TABLE 20

 at page 46) on to the groove of the interconnecting 

waveguide system flange. 

4.  Position the interconnecting waveguide system flange so that it aligns precisely with the 

waveguide flange of the RF output port (J7). 

5.  After alignment verification, loosely attach the interconnecting waveguide on to the RF output 

port using four #10-32 x 1/2 inch screws and four #10 lock washers (see 

TABLE 20

 at page 

46).  Finger-tight all screws. 

6.  Tighten all screws around the RF output port using a ‘star’ pattern to achieve uniform contact 

across the entire surface of the flange. 

5.3.3  E

LECTRICAL 

C

ONNECTIONS

 

 

The connector locations referred to in this Section are shown in 

Figure  5

 at page  24.  The 

electrical interconnections for the stand-alone unit consist of the Discrete Interface, RS-485 Serial 
Interface, RS-232 Serial Interface and the AC power. 

 

5.3.3.1 Discrete Interface 

 

If it is desired to use this interface, then construct an interconnecting cable by using the proper 
mating connector as described in 

TABLE  6

 at page  23 and with the correct pin assignment as 

listed in 

TABLE 3

 at page 19. Attach the interconnecting cable with connector to port (J3) of the 

SSPB and the user’s monitor and control system. 

NOTE: 

Whether this interface is being used or not, it is necessary to connect pin 1 of 
connector (J3) RELAY to pin 5 in order to enable (un-mute) the unit.  If pins 14 and 
5 of this interface are not connected together, the unit will remain muted. 

5.3.3.2 RS-485 Interface 

 
If it is desired to use this interface, then construct the interconnecting cable by using the proper 
mating connector as  described in 

TABLE  6

 at page  23 and with the correct pin assignment as 

shown in 

TABLE 5

 at page 20. Connect the free end of the interconnecting cable to the operator’s 

monitor and control system. 
 

If remote control through this interface is unnecessary, leave the port disconnected. 

CAUTION:

 Over-tightening the bolts may cause the stripping of the threads or distort the 

mating flange. 

Содержание SSPB-3000C

Страница 1: ...INSTALLATION AND OPERATION MANUAL 200 WATT L BAND TO C BAND RACK MOUNT SOLID STATE TRANSMITTER SSPB 3000C PM 150 50N415 6G0 Rev 1...

Страница 2: ...l shipping container box with the prepaid shipping charges ADVANTECH Advanced Microwave Technologies Inc 657 Orly Avenue Dorval Quebec H9P 1G1 CANADA Please indicate the RMA number on all shipping doc...

Страница 3: ...2 RS 232 INTERFACE 19 4 3 RS 485 INTERFACE 20 4 4 RF OUTPUT MONITOR INTERFACE 20 4 5 REDUNDANT INTERFACE 20 5 UNPACKING AND INSTALLATION 22 5 1 INITIAL INSPECTION 22 5 2 UNPACKING 22 5 3 INSTALLATION...

Страница 4: ...RUCTURE 41 9 2 COMMANDS 42 9 3 RESPONSE TO COMMANDS FROM SLAVE TO MASTER 43 9 3 1 Condition Status Response 43 9 3 2 Read Identification Response 43 9 3 3 Read Frequency Range Response 44 9 3 4 Read F...

Страница 5: ...IGURE 7 RS 232 COMMUNICATION VIA HYPERTERMINAL 35 FIGURE 8 HELP FUNCTION IN HYPERTERMINAL 37 FIGURE 9 REDUNDANT SYSTEM REAR VIEW 49 FIGURE 10 REDUNDANT SYSTEM LATERAL RIGHT VIEW 50 FIGURE 11 REDUNDANT...

Страница 6: ...INTERFACE CONNECTION INFORMATION RS 232 27 TABLE 9 POWER REQUIREMENTS 28 TABLE 10 AC LINE J5 CONNECTOR PIN ASSIGNMENTS 28 TABLE 11 RS 232 MENU ITEM DEFINITION 36 TABLE 12 COMPUTER TERMINAL COMMANDS F...

Страница 7: ...ltage The prime power potential of 180 264 VAC applied to the equipment is known to cause injury or death WARNING The operator cannot repair this equipment DO NOT attempt to remove the transmitter cov...

Страница 8: ...the transmitters built by Advantech e g less than 10 mW versus 10 to 500 W for the units The maximum permissible levels are currently being studied by a number of organisations In the past the U S Saf...

Страница 9: ...on to build a 1 1 redundant system 2 2 ABOUT THIS MANUAL This manual contains information that describes the installation operation and maintenance procedures for the 200 Watt C Band rack mount SSPB U...

Страница 10: ...SSBP 3000C Page 9 Figure 1 Product Outline...

Страница 11: ...able at this module the Alarm Up Converter output 3 2 POWER AMPLIFIER MODULE The Power Amplifier Module amplifies the RF C Band signals from the L C Band Up Converter module over the frequency range o...

Страница 12: ...capable of absorbing full reflective power A CPR 137 grooved waveguide flange is the output of the unit 3 4 10 MHZ OSCILLATOR This circuit is used to generate a 10 MHz reference signal with a high st...

Страница 13: ...is designed to operate between 0 C and 50 C ambient 2 Blockage at the air intake or exhaust vents 3 5 2 MUTE CONTROL The user can disable the RF output power remotely by 1 Leaving unconnected pins 1 a...

Страница 14: ...tts 3 7 COOLING SYSTEM The cooling system for the SSPB consists of four cooling fans Two fans are mounted at the front panel and the other two at the rear panel see Figure 1 at page 9 The Varifan powe...

Страница 15: ...LINE 9 V COOLING FANS 4 CURRENT SENSOR CS 12 V 12 V RV_PWR REFLECTED POWER DETECTOR 30 dB o C THERMISTOR DIGITAL POWER MONITOR 12 V RS 485_PM HPA L G N L N L N GND 9 V RS 485_PA TH 12 V SECONDARY POWE...

Страница 16: ...will be always dark MUTE LED Yellow LED When lit indicates that the RF circuits are disabled and no RF output power is delivered ALARM LED Yellow LED When lit indicates a temperature ALARM situation...

Страница 17: ...SSBP 3000C Page 16 Figure 3 Front Panel Assembly...

Страница 18: ...2 dBm min Third Order Intermodulation 26 dBc 2 equal tones 5 MHz apart each at 6 dB output back off from P1dB 36 dBc 2 equal tones 5 MHz apart each at 10 dB output back off from P1dB RF Output Frequen...

Страница 19: ...s the communication and remote control through the RS 485 serial communication port in packet mode 4 RF Output Monitor Interface This interface provides a sample of the output power of the unit throug...

Страница 20: ...2 TX_AL_COM indicates the FAULT state of the unit 5 MUTE_COMMON common 6 9 N C not connected 4 2 RS 232 INTERFACE This serial communication interface offers to the operator the essential monitoring an...

Страница 21: ...rial transmit TX 5 Common Serial port common System common 6 TX Serial port output Serial transmit TX 9 RX Serial port input Serial receive RX 4 4 RF OUTPUT MONITOR INTERFACE This RF output sample por...

Страница 22: ...UNIT A J1 J7 J6 1 UNIT B J1 J7 J6 1 SPLITTER IF INPUT TYPE N FEMALE RF INPUT B RF INPUT A RF OUT RF OUT TO ANTENNA WAVEGUIDE SWITCH B W G LOAD A W G W G REDUNDANT I F CABLE TO PC TRANSMITTER TRANSMIT...

Страница 23: ...items listed on the packing list see TABLE 20 at page 46 have been received If any of the items are missing immediately contact ADVANTECH Inspect all of the items for evidence of damage resulting from...

Страница 24: ...M J2 RS232 RS 232 Serial Interface DB 9S F DB 9P M J3 RELAY Discrete Interface DB 9S F DB 9P M OUTPUT MONITOR RF Output Monitor N Type F N Type M J5 AC Line IEC 320 M IEC 320 F J6 Redundant Interface...

Страница 25: ...SSBP 3000C Page 24 Figure 5 Connectors Location on Front and Back Panels...

Страница 26: ...are free of any obstructing debris TABLE 7 ENVIRONMENTAL CONDITIONS Temperature Non operating continuous exposure Operating ambient 40 C to 55 C 0 C to 50 C Relative Humidity Up to 90 relative humidi...

Страница 27: ...d alone unit consist of the Discrete Interface RS 485 Serial Interface RS 232 Serial Interface and the AC power 5 3 3 1 Discrete Interface If it is desired to use this interface then construct an inte...

Страница 28: ...Pin Signal Direction DB 9 DB 25 2 RX 3 2 3 TX 2 3 5 common 5 7 5 3 3 4 AC Power and Ground 1 Attach a ground cable to the ground stud provided on the rear panel see Figure 5 at page 24 2 Connect the r...

Страница 29: ...the front panel see Figure 5 at page 24 CAUTION Ensure that the proper pin is selected for AC operation Applying power on the wrong pin may permanently damage the SSPB necessitating factory repair CA...

Страница 30: ...e to withstand full CW RF power 7 The cooling fans are not obstructed 6 2 OPERATIONAL SETTINGS VERIFICATION The SSPB arrives with all of its factory pre set operational values that meet the requiremen...

Страница 31: ...PB failure due to the above condition will be attributed to abuse or neglect and will not be covered by the standard warranty 7 3 BASIC OPERATING PROCEDURE Perform the following operating procedure 1...

Страница 32: ...s to change the value Press the Enter key to confirm the new value or the CLEAR key to return without the changes 6 Adjust the attenuation at the mixer input of the L Band to C Band up converter modul...

Страница 33: ...the SSPB and the user s computer terminal See Section 5 3 3 at page 27 2 At the PC create a new folder 3 From the supplied source copy the file named DLAPP1 exe and the file with extension hex into th...

Страница 34: ...NTER Pwr 42 1 dBm SSPB STATUS Pwr 42 1 TxSt on ALARMS No Alarms CLEAR ENTER CLEAR Pwr 42 1 dBm TxFS 4900MHz Pwr 42 1 dBm TxGn 73 0dB CLEAR ENTER ENTER NAVIGATE MODIFY Pwr 42 1 dBm TxGn 73 0dB Pwr 42 1...

Страница 35: ...he SSPB via the RS 232 interface as follows 1 Switch on the power station s circuit breaker to power up the SSPB 2 Run any terminal program in the personal computer 3 Use the following communication p...

Страница 36: ...SSBP 3000C Page 35 Figure 7 RS 232 Communication via HyperTerminal...

Страница 37: ...al Oscillator frequency in MHz 4900 in this case FPWR Forward output Power in dBm 21 0 dBm in this case TxGain Transmission Gain in dB 62 0 dB in this case Tx Stat Transmission Status On in this case...

Страница 38: ...SSBP 3000C Page 37 Figure 8 Help function in HyperTerminal...

Страница 39: ...he adjustment of the transmission gain of the SSPB in dB Tx gain range 53 to 73 dB tsw Tx Switch Allows for the stand by unit to be switched on line redundant system only txm Tx Mute Transmission Mute...

Страница 40: ...on output power in dBm rpw Reflected PW Displays the reflected transmission power in dBm t1 Hand held Selects the hand held Terminal Mode t2 PC term Selects the PC Terminal Mode tfs Tx freq shift Disp...

Страница 41: ...ose connectors and improper sealing Tighten or replace waveguides as required 4 Check for other defects such as wear breakage deterioration fungus excess moisture and mounting integrity 8 3 COOLING FA...

Страница 42: ...s 0x05 will return address 0x50 The second byte in the master to slave direction is a command or a data request The third forth and fifth bytes in the master to slave direction carry the value of para...

Страница 43: ...Axxxx for Tx No Response 5 Read Identification 0x07 See TABLE 15 6 Read serial number 0x08 5 ASCII characters 3 Read RF frequency ranges 0x09 0x5A for Tx See TABLE 16 7 Read gain Set 0x0A 0x5A for Tx...

Страница 44: ...munication status 1 no communication 0 communication O K Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 N U N U L IF LIM RF L PA IF L L RF PM 9 3 2 READ IDENTIFICATION RESPONSE TABLE 15 READ IDENTIFI...

Страница 45: ...7 MS byte Lowest frequency LS byte Lowest frequency 0x5A for Tx 0xA5 for Rx MS byte Highest frequency LS byte Highest frequency 9 3 4 READ FREQUENCY SET RESPONSE TABLE 17 READ FREQUENCY SET RESPONSE...

Страница 46: ...rm Reflected power Alarm 1 Rx WG Sw Alarm 2 Rx 1 unmute 0 mute 1 L FR alarm 1 RF L alarm 1 TxWG SW not connected 3 Tx 1 on line 0 S B 1 PA temper alarm 1 LNX current alarm 1 RxWG SW not connected 4 Rx...

Страница 47: ...Sold Cup Plug 631 871380 001 5 3 Connector D Sub 9 Sold Cup Plug 631 871380 003 6 3 Connector D Sub 9 Backshell 631 925380 001 7 1 Power Entry IEC 320 634 113800 002 8 8 10 32x1 2 Mach Screw Phil Pan...

Страница 48: ...500100 201 8 1 Splitter Bracket 330 151023 101 9 1 Shipping Plate 330 151923 001 10 1 WR137 W G Switch 10V Ice Resistant Flange Grooved 570 137101 002 11 3 WR137 CPR Half Gasket Silicone 705 137000 0...

Страница 49: ...0 5kV Signal Lines 1 kV Power Lines IEC 1000 4 4 EN 50082 1 1998 Electrostatic Discharge contact and air discharge 4kV CD 8 kV AD IEC 1000 4 2 EN 50082 1 1998 Surge Immunity AC ports 1kV 0 5 kV IEC 10...

Страница 50: ...SSBP 3000C Page 49 Figure 9 Redundant System rear view...

Страница 51: ...SSBP 3000C Page 50 Figure 10 Redundant System lateral right view...

Страница 52: ...SSBP 3000C Page 51 Figure 11 Redundant System lateral left view...

Страница 53: ...SSBP 3000C Page 52 Figure 12 Redundant System top view...

Страница 54: ...SSBP 3000C Page 53 Figure 13 RS 232 Communication via HyperTerminal for Redundant System...

Страница 55: ...SSBP 3000C Page 54 Figure 14 Proposed Graphic User Interface for a Redundant System based on RS 485 Packet Protocol...

Отзывы: