2.6.5 Reference Ground Isolation and Coupling
The Carrier Board should maintain a well-designed analog ground plane around the components on the
primary side of the transformer between the transformer and the RJ-45 receptacle. The analog ground
plane is bonded to the shield of the external cable through the RJ-45 connector housing.
The analog ground plane should be coupled to the carrier’s digital logic ground plane using a capacitive
coupling circuit that meets the ground plane isolation requirements defined in the 802.3-2005
specification. It is recommended that the Carrier Board PCB design maintain a minimum 30 mil gap
between the digital logic ground plane and the analog ground plane.
It's recommended to place an optional GND to SHIELDGND connection near the RJ-45 connector to
improve EMI and ESD capabilities.