background image

Appendix

B

B

Watchdog Timer

This appendix gives you the infor-
mation about the watchdog timer 
programming on the SOM-3569 
CPU System on Module
Sections include:

 Watchdog Timer Programming

Содержание SOM-3569

Страница 1: ......

Страница 2: ...e of the information provided herein Our products are not intended for use in systems in which failures of product could result in personal injury All trademarks mentioned herein are property of their...

Страница 3: ...User Manual SOM 3569...

Страница 4: ...ion Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers nev...

Страница 5: ...f and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Страница 6: ...r dealer immediately SOM 3569 CPU module 1 x Heatspreader 1960083260N001 or 1960083261N001 Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are inc...

Страница 7: ...ur any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the...

Страница 8: ...mage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power befo...

Страница 9: ...chips identify Front 14 Figure 2 2 Board chips identify Rear 14 2 2 Mechanical Drawing 15 Figure 2 3 Board Mechanical Drawing Front 15 Figure 2 4 Board Mechanical Drawing Rear 15 Figure 2 5 Board Mech...

Страница 10: ...1Chipset Setup 39 3 5 1 North Bridge 40 Figure 3 22North Bridge 40 3 5 2 South Bridge 41 Figure 3 23South Bridge 41 3 5 3 Uncore Configuration 42 Figure 3 24Uncore Configuration 42 3 5 4 South Cluster...

Страница 11: ...l A 1 SOM 3569 Qseven R2 1 Pin Assignment 64 Appendix B Watchdog Timer 67 B 1 Programming the Watchdog Timer 68 Appendix C System Assignments 69 C 1 System I O Ports 70 C 2 Interrupt Assignments 72 C...

Страница 12: ...SOM 3569 User Manual x...

Страница 13: ...Chapter 1 1 General Information This chapter gives background information on the SOM 3569 CPU Computer on Module Sections include Introduction Functional Block Diagram Product Specification...

Страница 14: ...supports DX12 OpenGL 4 3 OGL ES 3 0 and OpenCL 2 0 In addition dual displays are supported as is HDMI DisplayPort with 4K2K resolution and dual channel LVDS at 1920x1200 full HD resolution is also ava...

Страница 15: ...control User storage area GPIO GbE Gigabit Ethernet HDA Intel High Definition Audio HD Audio refers to the specification released by Intel in 2004 for delivering high definition audio that is capable...

Страница 16: ...Golden Finger Channel A 24 Bit LVDS eDP DDI0 Channel B 24 Bit LVDS DP HDMI PCIe Port 0 3 USB 3 0 Port 1 USB2 0 Port 0 5 USB2 0 Port 6 7 USB3 0 Port 0 USB3 0 Port 1 USB2 0 Port 6 7 SATA Port 0 1 GEN 3...

Страница 17: ...2 USB2 0 ports 4 8 6 8 USB3 0 ports 0 3 2 1 LVDS channels embedded DisplayPort 0 0 Dual Channel 24 bit 2 Dual Cannel 24 bit 0 0 1 DisplayPort TMDS 0 1 1 HD Audio AC 97 I2S 0 1 1 HD Audio Ethernet 10 1...

Страница 18: ...LPC Supports Low Pin Count LPC 1 1 specification without DMA or bus mastering Allows connection to Super I O embedded controller or TPM LPC clock is 25MHz 1 3 7 Serial Bus 1 3 7 1 SMBus Supports SMBu...

Страница 19: ...Audio and LPE Audio for DDI 1 0 DisplayPort and HDMI 1 8V signal level up to 24 MHz serial data clock 1 3 8 7 SPI Bus Supports Master SPI operation only SPI clock can be 50MHz 33MHz or 20MHz capacity...

Страница 20: ...Power Management 1 3 9 1 Power Supply Supports both ATX and AT power modes VSB is for suspend power and can be option if not require standby suspend to RAM support RTC Battery may be option if keep t...

Страница 21: ...CE EN55022 Class B and FCC Certifications validate with standard development boards in Advantech chassis 1 3 11 MTBF Please refer Advantech SOM 3569 Series Reliability Prediction Report No TBD estimat...

Страница 22: ...ls 3 2 Burn in mode Burn In Test V8 1 Pro 1013 CPU RAM 2D 3D Graphics and Disk with 100 3 3 Idle mode DUT power management off and no running any program 4 OS Windows 10 Enterprise 1 3 15 Performance...

Страница 23: ...n and layout routing A schematic checklist will specify details about each pin s electrical properties and how to connect for different applications The layout checklist will specify the layout con st...

Страница 24: ...SOM 3569 User Manual 12...

Страница 25: ...Chapter 2 2 Mechanical Information This chapter gives mechanical information on the SOM 3569 CPU Computer on Module Sections include Board Information Mechanical Drawing Assembly Drawing...

Страница 26: ...while designing a carrier board to avoid mechanical and thermal issues for the best thermal dispassion performance Figure 2 1 Board chips identify Front Figure 2 2 Board chips identify Rear MIPI Conn...

Страница 27: ...nical Information 2 2 Mechanical Drawing For more details about 2D 3D models please look on the Advantech COM support service website http com advantech com Figure 2 3 Board Mechanical Drawing Front F...

Страница 28: ...SOM 3569 User Manual 16 Figure 2 5 Board Mechanical Drawing Side...

Страница 29: ...mation 2 3 Assembly Drawing These figures demonstrate the assembly order from the thermal module and COM module to the carrier board Figure 2 6 Assembly Drawing There are 4 reserved screw holes for SO...

Страница 30: ...sider the CPU and chip height tolerance when designing your thermal solution Intel Pentium and Celeron N and J Series Processors Figure 2 7 Main Chip Height and Tolerance Intel Pentium and Celeron N a...

Страница 31: ...Chapter 3 3 AMI BIOS This chapter gives BIOS setup information for the SOM 3569 CPU computer on module Sections include Introduction Entering Setup Hot Operation Key Exit BIOS Setup Utility...

Страница 32: ...settings and control various system features This chapter describes the basic navigation of the BIOS Setup Utility Figure 3 1 Setup program initial screen AMI s BIOS ROM has a built in Setup program...

Страница 33: ...has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured options in blue can The right frame displays the key legend Above the key leg...

Страница 34: ...n this section The Advanced BIOS Setup screens are shown below The sub menus are described on the following pages Figure 3 3 Advanced BIOS features setup screen Trusted Computing Trusted Computing Set...

Страница 35: ...st Technology Platform Trust Technology Security Configuration Intel R Anti Theft Technology Configuration 3 4 1 Trusted Computing Figure 3 4 Trusted Computing Security Device Support Enables or Disab...

Страница 36: ...I Auto Configuration Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Select the highest ACPI sleep s...

Страница 37: ...from EC and only set value when Save Changes Backlight Enable Polarity Switch Backlight Enable Polarity for Native or Invert Brightness PWM Polarity Backlight Control Brightness PWM Polarity for Nativ...

Страница 38: ...1 Serial Port 1 Configuration Figure 3 7 Serial Port 1 Configuration Serial Port Enable or Disable Serial Port COM Device Settings Set Parameters of Serial Port 1 COMA Change Settings Select an optima...

Страница 39: ...OS 3 4 3 2 Serial Port 2 Configuration Figure 3 8 Serial Port 2 Configuration Serial Port Enable or Disable Serial Port COM Device Settings Set Parameters of Serial Port 2 COMB Change Settings Select...

Страница 40: ...SOM 3569 User Manual 28 3 4 3 3 Hardware Monitor Figure 3 9 Hardware Monitor 3 4 4 Serial Port Console Redirection Figure 3 10 Serial Port console Redirection...

Страница 41: ...settings specify how the host computer and the remote computer which the user is using will exchange data Both computers should have the same or compatible settings Legacy Console Redirection Legacy C...

Страница 42: ...64 bit Displays if 64 bit is supported CPU Power Management CPU Power Management options Active Processor Cores Number of cores to enable in each processor package Intel Virtualization Technology When...

Страница 43: ...on Max CPU Speed Displays the Max CPU Speed Min CPU Speed Displays the Max CPU Speed Processor Cores Displays number of cores Intel HT Technology When Hyper threading is enabled 2 logical CPUS per cor...

Страница 44: ...3 13 CPU Power Management EIST Enable Disable Intel SpeedStep Turbo Mode Turbo Mode Boot performance mode Select the performance state that the BIOS will set before OS handoff C States Enable Disable...

Страница 45: ...33 SOM 3569 User Manual Chapter 3 AMI BIOS 3 4 6 Network Stack Configuration Figure 3 14 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack...

Страница 46: ...play mode for Option ROM INT19 Trap Response BIOS reaction on INT19 trapping by Option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during legacy boot Boot option filter This o...

Страница 47: ...35 SOM 3569 User Manual Chapter 3 AMI BIOS 3 4 8 NVMe Configuration Figure 3 16 NVMe Configuration 3 4 9 SDIO Configuration Figure 3 17 SDIO Configuration...

Страница 48: ...d off This is a workaround for OS without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver USB Mass Storage Driver Support Enable Disable USB Mass Storage Driver Suppor...

Страница 49: ...37 SOM 3569 User Manual Chapter 3 AMI BIOS 3 4 11 Platform Trust Technology Figure 3 19 Platform Trust Technology fTPM Enable Disable fTPM...

Страница 50: ...SOM 3569 User Manual 38 3 4 12 Security Configuration Figure 3 20 Security Configuration TXE HMRFPO TXE EOP Message Send EOP Message Before Enter OS...

Страница 51: ...er 3 AMI BIOS 3 5 Chipset Setup Figure 3 21 Chipset Setup North Bridge North Bridge Parameters South Bridge South Bridge Parameters Uncore Configuration Uncore Configuration South Cluster Configuratio...

Страница 52: ...n the System Memory Slot0 Memory in the slot Memory Slot1 Memory in the slot Memory Slot2 Memory in the slot Memory Slot3 Memory in the slot Above 4GB MMIO BIOS assignment Enable Disable above 4GB Mem...

Страница 53: ...41 SOM 3569 User Manual Chapter 3 AMI BIOS 3 5 2 South Bridge Figure 3 23 South Bridge Serial IRQ Mode Configure Serial IRQ Mode...

Страница 54: ...f S0ix is enabled This item will be read only if S0ix is enabled IGD LCD Control NXP non EDID Support NXP PTN3460 Support Enable Used internal EDID setting Disable Get EDID from DDC bus Color depth an...

Страница 55: ...figuration HD Audio Configuration Settings PCI Express Configuration PCI Express Configuration Settings SATA Drives Press Enter to select the SATA Device Configuration Setup options SCC Configuration...

Страница 56: ...SOM 3569 User Manual 44 3 5 4 1 HD Audio Configuration Figure 3 26 HD Audio Configuration HD Audio Support Enable Disable HD Audio Support...

Страница 57: ...r savings Enable Enable PCIe root port Disable Dis able PCIe root port PCI Express Root Port 1 Control the PCI Express Root Port AUTO To disable unused root port automatically for the most optimum pow...

Страница 58: ...the PCI Express Root Port AUTO To disable unused root port automatically for the most optimum power savings Enable Enable PCIe root port Disable Dis able PCIe root port ASPM PCI Express Active State P...

Страница 59: ...Port 0 PCI Express Root Port 0 Control the PCI Express Root Port AUTO To disable unused root port automatically for the most optimum power savings Enable Enable PCIe root port Disable Dis able PCIe ro...

Страница 60: ...I Express Root Port 1 Control the PCI Express Root Port AUTO To disable unused root port automatically for the most optimum power savings Enable Enable PCIe root port Disable Dis able PCIe root port A...

Страница 61: ...Port 2 PCI Express Root Port 2 Control the PCI Express Root Port AUTO To disable unused root port automatically for the most optimum power savings Enable Enable PCIe root port Disable Dis able PCIe ro...

Страница 62: ...I Express Root Port 3 Control the PCI Express Root Port AUTO To disable unused root port automatically for the most optimum power savings Enable Enable PCIe root port Disable Dis able PCIe root port A...

Страница 63: ...ion Chipset SATA Enables or Disables the Chipset SATA Controller The Chipset SATA controller sup ports the 2 black internal SATA ports up to 3Gb s supported per port SATA Mode Selection Determines how...

Страница 64: ...3 5 4 4 SCC Configuration Figure 3 34 SCC Configuration SCC SD Card Support D27 F0 Enable Disable SCC SD Card Support SCC eMMC Support D28 F0 Enable Disable SCC eMMC Support eMMC Max Speed Select the...

Страница 65: ...ration xHCI Mode Once disabled XHCI controller would be function disabled none of the USB devices are detectable and usable during boot and in OS Do not disable it unless for debug purpose XDCI Suppor...

Страница 66: ...en power is re applied after a power failure G3 state S0 State System will boot directly as soon as power applied S5 State System keeps in power off state until power button is pressed Wake On Lan Ena...

Страница 67: ...55 SOM 3569 User Manual Chapter 3 AMI BIOS 3 6 Security Chipset Figure 3 37 Security Chipset Setup Administrator Password Set Setup Administrator Password User Password Set User Password...

Страница 68: ...r setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option Priorities Boot Option...

Страница 69: ...saving the changes Discard Changes and Reset Reset system setup without saving any changes Default Options Restore Defaults Restore Load Default values for all the setup options Save as User Defaults...

Страница 70: ...SOM 3569 User Manual 58...

Страница 71: ...Chapter 4 4 S W Introduction Installation S W Introduction Driver Installation Advantech iManager...

Страница 72: ...ow Driver Setup instructions to complete the installation 4 2 2 Other OS SOM 3569 supports Linux 4 3 Advantech iManager Advantech s platforms come equipped with iManager a micro controller that provid...

Страница 73: ...61 SOM 3569 User Manual Chapter 4 S W Introduction Installation...

Страница 74: ...SOM 3569 User Manual 62...

Страница 75: ...Appendix A A Pin Assignment This appendix gives you the infor mation about the hardware pin assignment of the SOM 3569 CPU System on Module Sections include SOM 3569 Qseven R2 1 Pin Assignment...

Страница 76: ...I2 7 GBE_LINK100 8 GBE_LINK1000 9 GBE_MDI1 10 GBE_MDI0 11 GBE_MDI1 12 GBE_MDI0 13 GBE_LINK 14 GBE_ACT 15 NC 16 SUS_S4 17 WAKE 18 SUS_S3 19 GPO0 20 PWRBTN 21 SLP_BTN 22 LID_BTN 23 GND 24 GND KEY KEY 25...

Страница 77: ...0 LVDS_B2 111 LVDS_PPEN 112 LVDS_BLEN 113 eDP0_TX3 LVDS_A3 114 LVDS_B3 115 eDP0_TX3 LVDS_A3 116 LVDS_B3 117 GND 118 GND 119 eDP0_AUX LVDS_A_CLK 120 LVDS_B_CLK 121 eDP0_AUX LVDS_A_CLK 122 LVDS_B_CLK 12...

Страница 78: ...PC_AD1 187 LPC_AD2 188 LPC_AD3 189 LPC_CLK 190 LPC_FRAME 191 SERIRQ 192 NC 193 VCC_RTC 194 SPKR 195 FAN_TACHOIN 196 FAN_PWMOUT 197 GND 198 GND 199 SPI_MOSI 200 SPI_CS0 201 SPI_MISO 202 SPI_CS1 203 SPI...

Страница 79: ...Appendix B B Watchdog Timer This appendix gives you the infor mation about the watchdog timer programming on the SOM 3569 CPU System on Module Sections include Watchdog Timer Programming...

Страница 80: ...rom BIOS and then set to EC Only Win10 support it In other OS it will still use IRQ number from BIOS setting as usual For details please refer to iManager Software API User Manual Trigger Event Note I...

Страница 81: ...signments This appendix gives you the infor mation about the system resource allocation on the SOM 3569 CPU System on Module Sections include System I O ports DMA Channel Assignments Interrupt Assignm...

Страница 82: ...00400 0x0000047F Motherboard resources 0x00000500 0x000005FE Motherboard resources 0x00000600 0x0000061F Motherboard resources 0x0000164E 0x0000164F Motherboard resources 0x00000062 0x00000062 Microso...

Страница 83: ...oller 0x000000B8 0x000000B9 Programmable interrupt controller 0x000000BC 0x000000BD Programmable interrupt controller 0x000004D0 0x000004D1 Programmable interrupt controller 0x0000F000 0x0000F03F Inte...

Страница 84: ...el R Imaging Signal Processor 2600 IRQ 4294967280 Intel R USB 3 0 eXtensible Host Controller 1 0 Microsoft IRQ 4294967281 IRQ 4294967286 Intel R I211 Gigabit Network Connection IRQ 4294967287 Intel R...

Страница 85: ...Controller 5AB4 0xFED00000 0xFED003FF High precision event timer 0x82200000 0x8220FFFF Intel R USB 3 0 eXtensible Host Controller 1 0 Microsoft 0xA0000 0xBFFFF PCI Express Root Complex 0xC0000 0xDFFFF...

Страница 86: ...ions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Страница 87: ...tec de Germany Distec GmbH Augsburger Str 2b 82110 Germering Phone 49 89 894363 0 E Mail info distec de Internet www distec de Switzerland ALTRAC AG Bahnhofstra e 3 5436 W renlos Phone 41 44 7446111 E...

Отзывы:

Похожие инструкции для SOM-3569