SNMP-1000-B1 User’s Manual
4
Temperature Sensors:
LM75 digital temperature sensor, I2C interface, -30 ~ +125°C (-22 ~
+257°F)
Fan Speed Monitor:
Up to 9 fans, 700 ~ 10000 RPM
Power Good / Digital Input: .
High: > 2.4 V DC
Low: < 0.8 V DC
1.2.4 Firmware Specification
System Status Monitoring and Management
• Real-time healthy status monitoring: Provides real-time status display
in HTTP/Java graphical format
• History log graphic display and data down load
• Alarm event log
Alarm Notification
• E-mail: Can set up to 4 addresses to receive e-mails
• Alarm message display on the optional LCD display module
• SNMP trap: Notify up to 8 SNMP administrators
• Pager notification: Dial out through external modem to send message to
up to 8 pagers.
• Audible alarm sound
Supported Protocols
TCP, UDP, IP, ICMP, DHCP, BOOTP, ARP, SNMP, HTTP, Telnet
Management Function
• Web-based remote configure, control and monitor
• Remote reset, power down and power up.
• Remote digital output signal control
• Remote message display control
• Firmware upgrade from serial port and Ethernet port
• Modem dial in (console mode only)
1.2.5 LCD Message Display Module with Keys
• LCD module: 2 rows, 16 characters, with backlight
Содержание SNMP-1000-B1
Страница 1: ...SNMP 1000 B1 Intelligent SNMP HTTP Remote System Manager User s Manual...
Страница 10: ...SNMP 1000 B1 User s Manual x...
Страница 11: ...1 CHAPTER 1 Introduction...
Страница 16: ...SNMP 1000 B1 User s Manual 6...
Страница 17: ...7 CHAPTER 2 Hardware Installation...
Страница 27: ...17 CHAPTER 3 Getting Started...
Страница 38: ...SNMP 1000 B1 User s Manual 28 3 3 5 Main Menu...
Страница 48: ...SNMP 1000 B1 User s Manual 38...
Страница 49: ...39 Chapter4 CHAPTER 4 Programming the SNMP 1000 B1...
Страница 73: ...63 AppendixA Appendix A Connector Pin Assign ments...
Страница 86: ...SNMP 1000 B1 User s Manual 76...