SmartFlex SR310
7.3
Type tests and environmental conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
Enclosure air
±
6 kV
±
8 kV
RF field AM
modulated
EN 61000-4-3
Enclosure
10 V/m (80 – 1000 MHz)
10 V/m (1000 – 6000 MHz)
Fast transient
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
±
1 kV
±
1 kV
±
1 kV
Surge
EN 61000-4-5
Ethernet ports
Power ports
I/O ports
±
1 kV
±
1 kV
±
1 kV
RF conducted
EN 61000-4-6
All ports
10 V/m (0,15 – 80 MHz)
Radiated emission
EN 55032
Enclosure
Class B
Conducted
emission
EN 55032
DC power ports
Ethernet ports
Class B
Class B
Degrees of protec-
tion provided by en-
closures
EN 60529
IP30
Dry heat
EN 60068-2-2
s85
◦
C,ope75
◦
C
Cold
EN 60068-2-1
storage -40
◦
C
Damp heat
EN 60068-2-30
+55
◦
C / +25
◦
C, rel. humidity 95%, 6 h - 6 h
Shock
EN 60068-2-14
-40
◦
C/+75
◦
C, 3h/3h, 2 cycles, 3 K/min
Table 31: Type tests and environmental conditions