Advantech PCM-2610B Скачать руководство пользователя страница 1

PCM-261X Startup Manual 1

Before installation, please make sure that you have:
1.  mPCIe card with controller x 1
2.  Wired cable x 1
3.  DB37 to DB9(4 ports) cable x 1
4.  Startup manual x 1
5.  Warranty card x 1
6.  DB37 IO plate with bracket x 1

If any of these items are missing or damaged, contact your 

distributor or sales representative immediately. 

The driver can be downloaded from the product website.
* Supports Windows XP/7/8/10, and Linux

PCM-2610B

PCM-2612B 

4-Ports Non-Isolated RS-232 mPCIe, DB37

4-Ports Non-Isolated RS-422/485 mPCIe, DB37

Startup Manual

 

You can set the terminator resistor via jumper setting if 

necessary to match impedance.
PCM-2612B Jumper switch setting as below. 

Master/Slave Settings

COM 

Port

Switch

Pin

Setting

Descriptio

n

COM 1

SW1

1

ON

RS-422 Master

OFF

RS-485/RS-422 

Slave (Default)

COM 2

2

ON

RS-422 Master

OFF

RS-485/RS-422 

Slave (Default)

COM 3

3

ON

RS-422 Master

OFF

RS-485/RS-422 

Slave (Default)

COM 4

4

ON

RS-422 Master

OFF

RS-485/RS-422 

Slave (Default)

SW1

SW2

SW3

CN1

CN2

  Packing List

For more information on this and other Advantech 

products, please visit our website at

http://www.advantech.com

http://www.advantech.com/eAutomation

For technical support and service: 

http://www.advantech.com.tw/eservice

This manual is for PCM-2610B-AE/PCM-2612B-AE.

Part No. 2001261000 

Printed in China

1st Edition

March 2018

  Jumper Settings

  Documentation/Software Support Guide

Содержание PCM-2610B

Страница 1: ...ia jumper setting if necessary to match impedance PCM 2612B Jumper switch setting as below Master Slave Settings COM Port Switch Pin Setting Description COM 1 SW1 1 ON RS 422 Master OFF RS 485 RS 422 Slave Default COM 2 2 ON RS 422 Master OFF RS 485 RS 422 Slave Default COM 3 3 ON RS 422 Master OFF RS 485 RS 422 Slave Default COM 4 4 ON RS 422 Master OFF RS 485 RS 422 Slave Default SW1 SW2 SW3 CN1...

Страница 2: ... Data Data OFF Open Default 2 ON 120 Ohm between Rx Rx Invalid OFF Open Default COM 4 3 ON 120 Ohm between Tx Tx 120 Ohm between Data Data OFF Open Default 4 ON 120 Ohm between Rx Rx Invalid OFF Open Default Board ID Setting The comm cards feature a built in DIP switch for defining the card s board ID When multiple cards are installed the board ID switch is useful for identifying the device number...

Страница 3: ... RS 422 RS 485 1 20 3_RI 1 20 2 3_DCD 21 3_DTR 2 3_TxD 3_Data 21 3_RxD 3 3_GND 22 3_DSR 3 3_GND 3_GND 22 4 3_CTS 23 3_RTS 4 23 5 3_RxD 24 3_TxD 5 3_TxD 3_Data 24 3_RxD 6 4_RI 25 4_DCD 6 25 4_TxD 4_Data 7 4_DTR 26 4_GND 7 4_RxD 26 4_GND 4_GND 8 4_DSR 27 4_CTS 8 27 9 4_RTS 28 4_RxD 9 28 4_TxD 4_Data 10 4_TxD 29 2_RI 10 4_RxD 29 11 2_DCD 30 2_DTR 11 2_TxD 2_Data 30 2_RxD 12 2_GND 31 2_DSR 12 2_GND 2_...

Страница 4: ...e card and lock the screws 6 Connect IO plate to mPCIe card with the FFC cables TPC Embedded Panel Computer Installation PCM Module with iDoor technology supports following iAutomation Computing Platforms Standard Mount UNO 2000 DIN Rail Mount UNO 1000 Wall Mount UNO 3000 4 3 Panel Mount TPC xx51T xx82 TPC 2000 5000 16 9 Panel Mount TPC xx51WP xx81WP TPC 2000 5000 See the following page for instal...

Страница 5: ...ve the screws from the base plate and lift to remove 2 Insert the mPCIe card and lock the screws 3 Unscrew to remove the blank expansion plate 4 Insert the PCM IO plate through the blank plate hole and lock the screws Connect IO plate to mPCIe card with the FFC cables ...

Отзывы: