PCIE-1816_1816H User Manual
24
Analog Threshold Trigger
For analog input operations, an analog trigger event occurs when the PCIE-1816/
1816H detects a transition from above a threshold level to below a threshold level
(falling edge), or a transition from below a threshold level to above a threshold level
(rising edge). User should connect analog signals from external device or analog out-
put channel on board to external input signal ATRG0 and ATRG1. On the PCIE-1816/
1816H, the threshold level is set using a dedicated 16-bit DAC. By software, you can
program the threshold level by writing a voltage value to this DAC; this value can
range from -10V to +10V.
Figure 3.8 External Analog Trigger Source Connection
Analog Output Connection
The PCIE-1816/1816H provides two AO output channels. You can use the internal
precision -5 V or -10 V reference to generate 0 to +5 V or 0 to +10 V AO output. Use
an external reference for other AO output ranges. The maximum reference input volt-
age is ±10 V and maximum output scaling is ±10 V. Loading current for AO outputs
should not exceed 5 mA.
Содержание PCIE-1816
Страница 1: ...User Manual PCIE 1816 1816H 16 bit Multi function Card with PCI Express Bus ...
Страница 4: ...PCIE 1816_1816H User Manual iv ...
Страница 10: ...PCIE 1816_1816H User Manual 4 Figure 1 1 Installation Flow Chart ...
Страница 36: ...PCIE 1816_1816H User Manual 30 ...
Страница 37: ...Appendix A A Specifications ...
Страница 38: ...PCIE 1816_1816H User Manual 32 A 1 Function Block ...
Страница 42: ...PCIE 1816_1816H User Manual 36 ...
Страница 43: ...Appendix B B Operation Theory ...
Страница 61: ...55 PCIE 1816_1816H User Manual Appendix B Operation Theory ...