110 PCA-6157 User's Manual
Whenever you start up your system, the CPU card runs a series of
programs to test and initialize board hardware. If the routines
encounter an error in during the tests, you will either hear a few
short beeps or see an error message on the screen. There are two
kinds of errors: fatal and non-fatal. The system can usually
continue the boot up sequence with non-fatal errors. Non-fatal
error messages usually appear on the screen along with the
following instructions:
press <F1> to RESUME
Write down the message and press the F1 key to continue the
bootup sequence. The cure for most nonfatal error messages is
simply to run the BIOS SETUP program, discussed in Chapter 4.
If the routines encounter a fatal error, they will stop the tests and
output a message indicating which test failed. If the fatal error
comes before the screen device initializes, the card will indicate
the error code through a series of beeps.
You can also determine the number of the test that failed by
reading the LED indicators on the top of the PCA-6157 board.
Please make a note of any BIOS error codes before you contact
Advantech for technical support.