Intel® Atom™ SoC J1900/E3825 

Pico-ITX SBC, DDR3L, 18/24-bit 

LVDS, VGA or HDMI, 1 GbE, Half-

size Mini PCIe, 4 USB, 2 COM, 

SMBus, mSATA & MIOe 

Содержание MIO-2263

Страница 1: ...User Manual MIO 2263 Intel Atom SoC J1900 E3825 Pico ITX SBC DDR3L 18 24 bit LVDS VGA or HDMI 1 GbE Half size Mini PCIe 4 USB 2 COM SMBus mSATA MIOe ...

Страница 2: ...e nor for any infringements of the rights of third parties which may result from its use Acknowledgements AMI is a trademark of AMI Software International Inc Intel is a trademark of Intel Technologies Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Cor poration Intel and Atom are trademarks of Intel Corporation Microsoft Windows is a registered trademark of Microsoft ...

Страница 3: ...e used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pac...

Страница 4: ...A Power cable 5P 1 25 5P 2 0 SATA 5P 15 cm 1700002172 USB cable 2 0mm pitch USB A F 17cm 1700019705 AT Power cable 12cm 1960063455T001 99 5 x 70 5 x 15 7 mm Part Number Description 9666226300E Stud and screw pack including 1935031500 Screw R S D 5 3 H 2 M3 15L 4 pcs 1910002596 01 Stud F M3 10L M M3 5L B 5 H 19 4 pcs 193B0204C0 Screw F S D 3 5 H 0 8 M2 4L 2 pcs MIO 2263J U0A1E Intel Atom SoC J1900 ...

Страница 5: ...radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense The user is advised that any equipment changes or modifications...

Страница 6: ...our any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The e...

Страница 7: ...damage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive elec tronic components ...

Страница 8: ...MIO 2263 User Manual viii ...

Страница 9: ... layout Top side 12 Figure 2 2 Jumper and connector layout Bottom side 12 2 3 2 Board Dimensions 13 Figure 2 3 Board dimension layout Top side 13 Figure 2 4 Board dimension layout Bottom side 13 Figure 2 5 Board dimension layout coastline with power connec tor and heatsink 14 Figure 2 6 Board dimension layout coastline with Power connec tor and optional heatspreader 14 Figure 2 7 Board dimension l...

Страница 10: ... Assignments 59 A 1 Jumper Setting 60 Table A 1 Jumper List 60 A 2 Connectors 60 Table A 2 Connectors 60 Table A 3 J1 LCD Power Auto Power On 60 Appendix B WDT GPIO 81 B 1 Watchdog Timer Sample Code 82 B 2 GPIO Sample Code 83 Appendix C System Assignments 85 C 1 System I O Ports 86 Table C 1 System I O Ports 86 C 2 1st MB Memory Map 86 Table C 2 1st MB Memory Map 86 C 3 Interrupt Assignments 87 Ta...

Страница 11: ...Chapter 1 1 General Introduction This chapter gives background information on the MIO 2263 Sections include Introduction Product Features Specifications ...

Страница 12: ...m SoC J1900 E3825 BIOS AMI EFI 64 Mbit Flash BIOS System Memory DDR3L 1333 MHz for J1900 1066 MHz for E3825 up to 8 GB Watchdog Timer Single chip Watchdog 255 level interval timer setup by soft ware Expansion Interface 1 x half size mini PCIe slot 1 x MIOe connector supports 2 x USB 2 0 2 x PCIe x1 LPC HD Audio line out SMBus DP or HDMI supported by request 5 Vsb 12 Vsb power Battery Lithium 3 V 2...

Страница 13: ...to 1440 x 900 60 Hz Dual independent display LVDS VGA or HDMI LVDS Control Hub Intel Atom SoC processor J1900 E3825 Audio High Definition Audio HD ALC 888S codec Up to 2 channel of PCM Pulse Code Modulation audio out put Connectors Line out Line in PCI Express Interface 4 PCI Express x1 Lanes Lane 1 2 MIOe connector Lane 3 Half size Mini PCIe connector Lane 4 Intel i210 GbE controller SATA Interfa...

Страница 14: ... 2 4 2 Power Consumption Typical in Windows 8 Idle Mode J1900 0 85 A 12 V 10 2 W E3825 0 59 A 12 V 7 08 W Max in Windows 8 HCT12 10 minutes J1900 1 04 A 12 V 12 48 W E3825 0 76 A 12 V 9 12 W 1 2 4 3 RTC Battery Typical Voltage 3 0 V Normal discharge capacity 210 mAh Ethernet Controller Intel i210 GbE1 Compliant with IEEE 802 3 IEEE 802 3u IEEE 802 3z IEEE 802 ab Support 10 100 1000 Mbps Connectors...

Страница 15: ...DP HDMI DDR3L 1333 1066 SO DIMM up to 8GB Super I O Intel Atom SoC E3825 J1900 Single Channel LPC 2 x USB2 0 Half size Mini PCIe PCIe x 1 USB2 0 Half size mSATA SATAII 300MB s 1 x SATA II SATAII 300MB s VGA RGB HDMI DDI0 SMBus 2 PCIe x1 HD Audio Line out 2 x USB2 0 LPC 12Vsb 5Vsb Reset Transmitter USB Hub MIOe 1 x USB 3 0 USB2 0 USB3 0 1 x USB 2 0 USB2 0 AMI BIOS SPI ALC888S 2 x USB 2 0 18 24 bit ...

Страница 16: ...MIO 2263 User Manual 6 ...

Страница 17: ...he setup procedures of the MIO 2263 hard ware including instructions on setting jumpers and connecting peripherals as well as switches indicators and mechanical draw ings Be sure to read all safety precautions before you begin the installation procedure ...

Страница 18: ...atically depicted in this manual as follows A pair of needle nose pliers may be helpful when working with jumpers If you have any doubts about the best hardware configuration for your application contact your local distributor or sales representative before you make any changes Generally you simply need a standard cable to make most connections 2 1 2 Jumper List 2 1 3 Jumper Settings Warning To av...

Страница 19: ... DIMM socket supports DDR3L 1333 MHz J1900 1066 MHz E3825 up to 8 GB CN1 12 V Power Input CN2 DC JACK by request CN3 12 V Power Input 2 x 3 pin support by request CN6 DDR3 SO DIMM CN9 GPIO CN11 VGA CN12 HDMI CN13 Front Panel CN14 SATA CN15 mSATA CN16 Mini PCIe CN18 Internal USB CN19 External USB 3 0 USB 2 0 CN20 COM1 COM2 CN24 Gigabit Ethernet CN27 HD Audio CN29 MIOe CN30 Inverter Power Internal S...

Страница 20: ...el Connector CN13 MIO 2263 integrates below functions as front panel 6pin connector Power button Supports power on off button in ATX mode Reset If you install a reset switch it should be an open single pole switch Momentarily pressing the switch will activate a reset Power LED Power LED indicator would light when power is on HDD LED HDD LED indicator for hard disk access is an active low signal 2 ...

Страница 21: ...der for audio device It can support high definition audio stereo by customized audio module that has codec onboard 2 2 2 14 MIOe connector CN29 MIO 2263 supports MIOe connector to extend flexible I Os Interface 2 x USB 2 0 2 x PCIe x1 LPC HD Audio line out SMBus DP or HDMI supported by request 5 Vsb 12 Vsb power Total peripheral power supply output 5 V 3 A for CPU board and MI O Extension module t...

Страница 22: ...nical 2 3 1 Jumper and Connector Locations Figure 2 1 Jumper and Connector layout Top side Figure 2 2 Jumper and connector layout Bottom side CN11 CN13 CN27 CN20 CN6 CN31 J1 CN16 CN1 CN11 CN19 CN24 CN14 CN29 CN30 CN33 CN18 CN9 CN15 BH1 ...

Страница 23: ...Top side Figure 2 4 Board dimension layout Bottom side unit mm 0 3 27 41 91 96 75 100 0 3 25 29 41 57 70 68 75 72 0 3 25 26 83 34 10 45 35 68 75 0 3 25 5 06 14 58 96 75 unit mm 0 3 25 4 35 22 40 31 10 64 18 83 49 96 73 0 3 25 10 87 10 92 15 62 62 16 68 75 72 0 3 25 37 12 42 91 53 84 70 94 83 81 92 57 0 3 25 3 63 6 83 27 86 34 55 69 60 ...

Страница 24: ...t coastline with Power connector and optional heatspreader Figure 2 7 Board dimension layout coastline with optional DC jack 40 56 65 40 83 31 6 35 8 38 16 51 100 16 34 4 28 104 36 3 20 17 29 40 56 65 40 83 31 6 35 8 38 16 51 100 16 34 4 28 104 36 3 20 12 79 40 56 65 40 83 31 6 35 8 38 46 23 100 16 34 4 28 104 36 3 20 10 99 17 27 6 55 ...

Страница 25: ...owing drawing for MI O module height constraints Figure 2 8 MI O module height constraints Note 1 Constraint of components max height of MI O module base on 16 mm height MIOe connector If needed there s a 19 mm height con nector as well 2 The height of power connector including of cable on MIO 2263 should be considered when assembling the system or stacking the MI O module unit mm ...

Страница 26: ...der should be smaller the smaller the better 2 The height of the existing heat spreader is 11 2mm Advantech P N 1960065074N001 If you need some other height to fit the chassis better Advantech can customize it for you Please contact our sales for details 3 Thermal grease and screws are provided in heat spreader kit thermal grease helps conduct better if the chassis is quite close to heat spreader ...

Страница 27: ...Chapter 3 3 BIOS Settings ...

Страница 28: ...cribes the basic navigation of the MIO 2263 BIOS setup screens AMI s BIOS ROM has a built in Setup program that allows users to modify the basic system configuration This information is stored in flash ROM so it retains the Setup information when the power is turned off Note Default BIOS is supported for 64 bit OS installation BIOS for 32 bit OS is supported by project please contact with sales re...

Страница 29: ...the Main setup screen by selecting the Main tab There are two Main Setup options They are described in this section The Main BIOS Setup screen is shown below The Main BIOS setup screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured options in blue can The right frame displays the key legend Above the key legend is an area ...

Страница 30: ...can select any item in the left frame of the screen such as CPU Configuration to go to the sub menu for that item Users can display an Advanced BIOS Setup option by highlighting it using the Arrow keys All Advanced BIOS Setup options are described in this section The Advanced BIOS Setup screens are shown below The sub menus are described on the following pages ...

Страница 31: ...IOS ACPI auto configuration Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed Lock Legacy Resources Enables or Disables Lock of Legacy Resources ...

Страница 32: ...MIO 2263 User Manual 22 3 2 2 2 Super I O Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2 COMB ...

Страница 33: ...23 MIO 2263 User Manual Chapter 3 BIOS Settings 3 2 2 3 H W Monitor Pc Health Status This page displays all the information about system Temperature Voltage ...

Страница 34: ...5 RTC Wake Settings Wake system with Fixed Time Enable or disable System wake on alarm event Selecting FixedTime system will wake on the hr min sec specified Selecting DynamicTime System will wake on the current time Increase minute s ...

Страница 35: ...ial Port Console Redirection Console Redirection This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services EMS Console Redirection This item allows users to configure console redirection detail settings ...

Страница 36: ...cute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when com bined with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 RedHat Enterprise 3 Update 3 Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Power Technology Enables power management features ...

Страница 37: ...Chapter 3 BIOS Settings 3 2 2 7 PPM Configuration CPU C state Report Enable Disable CPU C state report to OS Max CPU C state This option controls Max C states that the processor will support S0ix Enable Disable CPU S0ix state ...

Страница 38: ...Serial ATA SATA Enable Disable Serial ATA SATA Test Mode Test Mode Enable Disable SATA Speed Support SATA Speed Supports Gen1 or Gen2 SATA ODD Port SATA ODD is Port0 or Port1 SATA Mode Select IDE AHCI Serial ATA Port 0 Enable Disable Serial ATA Port 0 ...

Страница 39: ...29 MIO 2263 User Manual Chapter 3 BIOS Settings 3 2 2 9 Miscellaneous Configuration OS Selection OS Selection to choose Windows 8 X Windows 7 ...

Страница 40: ... ROM INT19 Trap Response BIOS reaction on INT19 trapping by Option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during legacy boot Boot option filter This option controls Legacy UEFI ROMs priority Network Controls the execution of UEFI and Legacy PXE OpROM Storage Controls the execution of UEFI and Legacy Storage OpROM Video Controls the execution of UEFI and Legacy Video O...

Страница 41: ... Enables or Disables BIOS support for security device OS will not show Security Device TCG EFI protocol and INT1A interface will not be available MIO 2263 doesn t include TPM device If the client require TPM function of MIO 2263 please contact with Advantech Co directly for more details ...

Страница 42: ...ed by the XHCI driver EHCI Hand Off This is a workaround for OS without EHCI hand off support The EHCI owner ship change should be claimed by EHCI driver USB Mass Storage Driver Support This item allows you to enable or disable the USB mass storage device support Device reset time out USB mass storage device start unit command time out Device power up delay Maximum time the device will take before...

Страница 43: ...le or disable the SMART self test function TXE TXE HMRFPO Disable TXE Firmware Update TXE EOP Message Send EOP Message before entering the OS TXE Unconfiguration Perform Revert TXE settings to factory defaults Intel R AT Enable Disable BIOS AT code from running Intel R AT Platform PBA Enable Disable BIOS AT code from running ...

Страница 44: ...MIO 2263 User Manual 34 3 2 3 Chipset Configuration North Bridge Details for North Bridge items LVDS Config Select Detail for display items ...

Страница 45: ...hapter 3 BIOS Settings 3 2 3 1 North Bridge Intel IGD Configuration Config Intel IGD settings Graphics Power Management Control Graphics Power Management Control options LCD Control LCD Control Max TOLUD Maximum value of TOLUD ...

Страница 46: ...Enable Disable protected audio video control DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed graphics memory size used by the Inter nal graphics device DVMT Total Gfx Mem Select DVMT 5 0 total graphic memory size used by the internal graphics device Aperture Size Select the aperture size GTT Size Select the GTT size IGD Thermal Enable Disable IGD thermal Spread Spectrum clock Enable Disable...

Страница 47: ...37 MIO 2263 User Manual Chapter 3 BIOS Settings 3 2 3 3 Graphics Power Management Control RC6 Render Standby Check to enable render standby support ...

Страница 48: ... Display Select the video device which will be activated during POST This has no effect if external graphics are present Secondary boot display selection will appear based on your selection VGA modes will be supported only on the primary dis play LVDS Panel Type ...

Страница 49: ...oss This item allows you to select system restore states if AC power loss Azalia HD Audio Azalia HD audio options USB Configuration USB configuration settings PCI Express Configuration PCI Express configuration settings LAN1 Control Enable or Disable the LAN1 LAN1 PXE OpROM Enable or Disable boot option for LAN1 controller PCIE Wake Enable or Disable PCIE to wake the system from S5 Restore AC Powe...

Страница 50: ...3 2 3 6 Azalia HD Audio Audio Controller Control Detection of the Azalia device Disabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally Enabled Auto Azalia will be enabled if present disabled otherwise Azalia HDMI Codec Enable Disable internal HDMI codec for Azalia HDMI Port B Enable Disable HDMI Port B HDMI Port C Enable Disable HDMI Port C ...

Страница 51: ...of xHCI controller USB2 Link Power Management Enable Disable USB2 Link Power Management USB 2 0 EHCI Support Control the USB EHCI USB 2 0 functions One EHCI controller must always be enabled USB Per Port Control Control each of the USB ports 0 3 Enable Enable USB per port Disable Use USB port X settings ...

Страница 52: ...263 User Manual 42 3 2 3 8 PCI Express Configuration PCI Express Port 0 Enable or Disable the PCI Express Port 0 in the chipset Hot Plug Enable or disable PCI Express Hot Plug Speed Configure PCIe port speed ...

Страница 53: ...rity Setup from the MIO 2263 Setup main BIOS setup menu All Security Setup options such as password protection and virus protection are described in this section To access the sub menu for the following items select the item and press Enter Change Administrator User Password ...

Страница 54: ...535 0xFFFF indicates that firm ware will wait for user input before booting This means the default boot selec tion is not automatically started by the firmware Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables the Quiet Boot option Fast Boot Enables or disables boot with initialization of a minimal set of devices required to launch active boot option Has no effe...

Страница 55: ...m allows you to rest system setup without saving any changes Save Changes This item allows you to save changes done so far to any of the options Discard Changes This item allows you to discard changes done so far to any of the options Restore Defaults This item allows you to restore load default values for all the options Save as User Defaults This item allows you to save the changes done so far a...

Страница 56: ...MIO 2263 User Manual 46 ...

Страница 57: ...Chapter 4 4 S W Introduction Installation ...

Страница 58: ...add on value for Advantech platforms 4 3 1 SUSI Introduction To make hardware easier and more convenient to access for programmers Advan tech has released a suite of API Application Programming Interface in the form of a program library The program Library is called Secured and Unified Smart Interface or SUSI for short In modern operating systems user space applications cannot access hardware dire...

Страница 59: ...oper to control the backlight screen on off in an embedded device 4 3 2 4 The Watchdog API A watchdog timer abbreviated as WDT is a hardware device which triggers an action e g rebooting the system if the system does not reset the timer within a spe cific period of time The WDT API in SUSI provides developers with functions such as starting the timer resetting the timer and setting the timeout val...

Страница 60: ...ection illustrates the installation process 1 Extract Susi zip 2 Double click the Setup exe file The installer searches for a previous installation of the SUSI Library If it locates one a dialog box opens asking whether you want to modify repair or remove the soft ware If a previous version is located please see the Maintenance Setup section If it is not located an alternative window appears Click...

Страница 61: ... code of SusiDemo exe must be com piled under Microsoft Visual C 6 0 on Windows 7 Developers must add the header file Susi h and library Susi lib to their own projects when they want to develop some thing with SUSI SusiDemo exe The SusiDemo exe test application is an application which uses all functions of the SUSI Library It has five major function blocks Watchdog GPIO SMBus I2 C and VGA control ...

Страница 62: ...tatus of the GPIO pin will be dis played in R W Result field Test Read Multiple Input Pin Click the radio button Multi Pin Key in the pin number from 0x01 to 0x0F to read the value of the input pin The pin numbers are ordered bitwise i e bit 0 stands for GPIO 0 bit 1 stands for GPIO 1 etc For example if you want to read pin 0 1 and 3 the pin num bers should be 0x0B Click READ GPIO DATA button and ...

Страница 63: ...you want to set pin 0 and 1 high 3 to low the pin number should be 0x0B and then you should key in the value 0x0A to write Click the WRITE GPIO DATA button to write the GPIO output pins SMBus When the application has executed you can click the radio button to choose to test each access mode i e Access a byte Access multiple bytes and Access a word All data must be read or written in hexadecimal ex...

Страница 64: ...TA button and the data will be written to the device through the SMBus Read Multiple bytes Click the radio button Access multiple bytes Key in the slave device address in the Slave address field Key in the register offset in the Register Offset field Key in the desired number of bytes such as 3 in the right side field of radio button Access multiple bytes The number must be written in decimal Clic...

Страница 65: ...l as follows Screen on off control Click the radio button ON or push the key F11 to turn on the panel screen Click the radio button OFF or push the key F12 to turn off the panel screen The display chip of your platform must be in the support list in Appendix A or this function cannot work Brightness control Move the slider in increments using either the mouse or the direction keys or click the UP ...

Страница 66: ...e functional ity of the watchdog as follows Set the timeout value 3000 3 sec in the SET TIMEOUT field and set the delay value 2000 2 sec in the SET DELAY field then click the START button The Timeout Countdown field will countdown the watchdog timer and display 5000 5 sec Before the timer counts down to zero you can reset the timer by clicking the REFRESH button After you click this button the Tim...

Страница 67: ...plication is executed by clicking the button hardware monitoring data values will be displayed If certain data values are not supported by the platform the correspondent data field will be grayed out with a value of 0 For more details on MIO 2263 software API please contact your dealer or Advantech AE ...

Страница 68: ...MIO 2263 User Manual 58 ...

Страница 69: ...Appendix A A PIN Assignments ...

Страница 70: ... HDMI CN13 Front Panel CN14 SATA CN15 mSATA CN16 Mini PCIe CN18 Internal USB CN19 External USB 3 0 USB 2 0 CN20 COM1 COM2 CN24 Gigabit Ethernet CN27 HD Audio CN29 MIOe CN30 Inverter Power Internal SATA Power CN31 18 24 bits LVDS Panel CN33 SMBus BH1 Battery Table A 3 J1 LCD Power Auto Power On Part Number 1653003260 Footprint HD_3x2P_79 Description PIN HEADER 3 2P 180D M 2 0mm SMD SOUARE PIN Setti...

Страница 71: ...2 DC JACK by request Part Number 1652005684 Footprint PJ_3P_DCJ RPBT5NW 25 Description Pin Pin Name 1 VIN 2 GND CN3 12V Power Input 2 x 3 pin support by request Part Number 1655000025 Footprint WF_3x2P_79_BOX_D Description Pin Pin Name 1 GND 2 12V 3 GND 4 12V 5 GND 6 12V CN6 DDR3L SO DIMM Part Number 1651002083 Footprint DDR3_204P_AS0A626 JA Description Pin Pin Name ...

Страница 72: ... 0 mm Pin Pin Name 1 5 V 2 GPIO4 3 GPIO0 4 GPIO5 5 GPIO1 6 GPIO6 7 GPIO2 8 GPIO7 9 GPIO3 10 GND CN11 VGA Part Number 1654000055 Footprint DBVGA VF5MS Description D SUB Conn 15P 90D F DIP 070242FR015S200ZU Pin Pin Name 1 RED 2 GREEN 3 BLUE 4 NC 5 GND 6 GND 7 GND 8 GND 9 NC 10 GND 11 NC 12 DDAT 13 HSYNC 14 VSYNC 15 DCLK ...

Страница 73: ...MDP_TX0 4 HMDP_TX1 5 GND 6 HMDP_TX1 7 HMDP_TX2 8 GND 9 HMDP_TX2 10 HMDP_TX3 11 GND 12 HMDP_TX3 13 N A 14 N A 15 HMDP_DCLK 16 HMDP_DDAT 17 GND 18 5V Power 19 Hot Plug Detect CN13 Front Panel Part Number 1653004883 Footprint HD_3x2P_79_RA_21N22050 Description Pin Pin Name 1 Power Button Pin1 2 Power LED 3 Power Reset Button Pin2 4 HDD LED 5 Reset Button Pin1 6 HDD LED ...

Страница 74: ...SB1U Description Pin Pin Name 1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND CN15 mSATA Part Number 1654002538 Footprint MINIPCIE_HALF_PICO_ITX Description Pin Pin Name 1 NC 2 3 3V 3 NC 4 GND 5 NC 6 1 5V 7 NC 8 NC 9 GND 10 NC 11 NC 12 NC 13 NC 14 NC 15 GND 16 NC 17 NC 18 GND 19 NC 20 NC 21 GND 22 NC ...

Страница 75: ...ND CN15 mSATA Part Number 1654002538 Footprint MINIPCIE_HALF_PICO_ITX Description Pin Pin Name 27 GND 28 1 5V 29 GND 30 SMB_CLK 31 A 32 SMB_DAT 33 A 34 GND 35 GND 36 NC 37 GND 38 NC 39 3 3V 40 GND 41 3 3V 42 NC 43 NC 44 NC 45 NC 46 NC 47 NC 48 1 5V 49 NC 50 GND 51 NC 52 3 3V ...

Страница 76: ... 1654002538 Footprint MINIPCIE_HALF_PICO2600 Description Pin Pin Name 1 WAKE 2 3 3VSB 3 NC 4 GND 5 NC 6 1 5V 7 NC 8 NC 9 GND 10 NC 11 REFCLK 12 NC 13 REFCLK 14 NC 15 GND 16 NC 17 NC 18 GND 19 NC 20 NC 21 GND 22 PERST 23 PERn0 24 3 3VSB 25 PERp0 26 GND ...

Страница 77: ...r 1654002538 Footprint MINIPCIE_HALF_PICO2600 Description Pin Pin Name 27 GND 28 1 5 V 29 GND 30 SMB_CLK 31 PETn0 32 SMB_DAT 33 PETp0 34 GND 35 GND 36 USB D 37 GND 38 USB D 39 3 3 VSB 40 GND 41 3 3 VSB 42 NC 43 GND 44 NC 45 NC 46 NC 47 NC 48 1 5 V 49 NC 50 GND 51 NC 52 3 3 VSB ...

Страница 78: ...n PIN HEADER 2 5P 180D M 2 0 mm SMD IDIOT PROOF Pin Pin Name 1 5 V 2 5 V 3 A_D 4 B_D 5 A_D 6 B_D 7 GND 8 GND 9 GND CN19 External USB2 0 USB3 0 Part Number 1654010199 Footprint USB_13P_UEA1112C UHS6 4F Description Pin Pin Name 1 5V 2 D 3 D 4 GND 5 SSRX 6 SSRX 7 GND 8 SSTX 9 SSTX 10 5V 11 D 12 D 13 GND ...

Страница 79: ...signments CN20 COM1 COM2 Part Number 1653003720 Footprint HD_10x2P_79_RA Description Pin Pin Name 1 DCD1 2 DSR1 3 RXD1 4 RTS1 5 TXD1 6 CTS1 7 DTR1 8 RI1 9 GND 10 GND 11 DCD2 12 DSR2 13 RXD2 14 RTS2 15 TXD2 16 CTS2 17 DTR2 18 RI2 19 GND 20 GND ...

Страница 80: ... Description Pin Pin Name 1 BI_DA GHz 2 BI_DA GHz 3 BI_DB GHz 4 BI_DC GHz 5 BI_DC GHz 6 BI_DB GHz 7 BI_DD GHz 8 BI_DD GHz H3 GND H4 GND CN27 HD Audio Part Number 1653003719 Footprint HD_5x2P_79_RA_21N22050 Description Pin Pin Name 1 LOUTR 2 LINR 3 GND 4 GND 5 LOUTL 6 LINL 7 GND 8 GND 9 MIC1R 10 MIC1L ...

Страница 81: ...654006235 Footprint BB_40x2P_32_1625x285_2HOLD Description Pin Pin Name 1 GND 2 GND 3 PCIE_RX0 4 PCIE_TX0 5 PCIE_RX0 6 PCIE_TX0 7 GND 8 GND 9 PCIE_RX1 10 PCIE_TX1 11 PCIE_RX1 12 PCIE_TX1 13 GND 14 GND 15 NC 16 NC 17 NC 18 NC 19 GND 20 GND 21 NC 22 NC 23 NC 24 NC 25 GND 26 GND ...

Страница 82: ...MIO 2263 User Manual 72 ...

Страница 83: ..._40x2P_32_1625x285_2HOLD Description Pin Pin Name 27 PCIE_CLK 28 LOUTL 29 PCIE_CLK 30 LOUTR 31 GND 32 AGND 33 SMB_CLK 34 SCI 35 SMB_DAT 36 NC 37 PCIE_WAKE 38 NC 39 RESET 40 NC 41 SLP_S3 42 CLK33M 43 NC 44 LPC_AD0 45 DDP_HPD 46 LPC_AD1 47 GND 48 LPC_AD2 49 DDP_AUX 50 LPC_AD3 51 DDP_AUX 52 LPC_DRQ 0 ...

Страница 84: ...MIO 2263 User Manual 74 ...

Страница 85: ...40x2P_32_1625x285_2HOLD Description Pin Pin Name 53 GND 54 LPC_SERIRQ 55 DDP_D0 56 LPC_FRAME 57 DDP_D0 58 GND 59 GND 60 USB0_D 61 DDP_D1 62 USB0_D 63 DDP_D1 64 GND 65 GND 66 USB1_D USB_SSTX 67 DDP_D2 68 USB1_D USB_SSTX 69 DDP_D2 70 GND 71 GND 72 NC 73 DDP_D3 74 NC 75 DDP_D3 76 GND 77 GND 78 USB_OC ...

Страница 86: ...MIO 2263 User Manual 76 ...

Страница 87: ... User Manual Appendix A PIN Assignments CN29 MIOe Part Number 1654006235 Footprint BB_40x2P_32_1625x285_2HOLD Description Pin Pin Name 79 12VSB 80 12VSB 83 GND 84 GND 85 GND 86 GND 87 5VSB 88 5VSB 89 5VSB 90 5VSB ...

Страница 88: ...5P 90D Male SMD 852040 Pin Pin Name 1 12V 2 GND 3 ENABKL 4 VBR 5 5V CN31 18 24 bits LVDS Panel Part Number 1655000753 Footprint WF14P_49_BOX_RA_85204 14001 Description Pin Pin Name 1 GND 2 GND 3 LVDS0_CLK 4 LVDS0_CLK 5 LVDS0_D3 6 LVDS0_D3 7 LVDS0_D2 8 LVDS0_D2 9 LVDS0_D1 10 LVDS0_D1 11 LVDS0_D0 12 LVDS0_D0 13 5 V or 3 3 V 14 5 V or 3 3 V ...

Страница 89: ...O 2263 User Manual Appendix A PIN Assignments CN33 SMBus Part Number 1655904020 Footprint FPC4V 125M Description Wafer SMT 1 25 mm S T type 4P 180D M 85205 04001 Pin Pin Name 1 GND 2 SMB_DAT 3 SMB_CLK 4 5 V ...

Страница 90: ...MIO 2263 User Manual 80 ...

Страница 91: ...Appendix B B WDT GPIO ...

Страница 92: ... mov al 00h out dx al model small 486p stack 256 data SCH3114_IO EQU A00h code org 100h STARTup 47H enable WDT function bit 0 0Ch mov dx SCH3114_IO 47h mov al 0Ch out dx al 65H bit 1 0 Reserved bit 6 2 Reserve 00000 bit 7 WDT time out Value Units Select Minutes 0 default Seconds 1 mov dx SCH3114_IO 65h mov al 080h out dx al 66H WDT timer time out value bit 7 0 0 255 mov dx SCH3114_IO 66h mov al 01...

Страница 93: ...code org 100h STARTup Configuration GPIO as GPI or GPO by below register GPIO0 23H GPIO4 27H GPIO1 24H GPIO5 29H GPIO2 25H GPIO6 2AH GPIO3 26H GPIO7 2BH Set 00H as output type set 01H as input type Register 4BH configuration GPO value as high or low 1 HIGH 0 LOW mov dx SCH3114_IO 23h GPIO 0 mov al 00h Set GPIO 0 as output type out dx al mov dx SCH3114_IO 4Bh mov al 01h Set GPIO 0 as high value out...

Страница 94: ...MIO 2263 User Manual 84 ...

Страница 95: ...Appendix C C System Assignments ...

Страница 96: ... real time clock 80 92 Motherboard resources A0 B1 Interrupt Controller B2 B3 Motherboard resources B4 BD Interrupt Controller 2F8 2FF COM2 3B0 3DF Intel HD Graphics 3F8 3FF COM1 400 47F Motherboard resources 4D0 4D1 Interrupt Controller 500 57F Motherboard resources Table C 2 1st MB Memory Map Addr Range Hex Device A0000h BFFFFh IntelQ HD Graphics A0000h BFFFFh PCI Bus C0000h DFFFFh PCI Bus E0000...

Страница 97: ...ystem timer IRQ1 Using SERIRQ Keyboard Emulation IRQ2 Slave controller INTR output IRQ3 Communications Port COM2 IRQ4 Communications Port COM1 IRQ5 Available IRQ6 Available IRQ7 Available IRQ8 Internal RTC or HPET IRQ9 Microsoft ACPI Compliant System IRQ10 Available IRQ11 SMBus Port IRQ12 Available IRQ13 Numeric data processor IRQ14 SATA controller IRQ15 SATA controller ...

Страница 98: ...tions are subject to change without notice No part of this publicati on may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2014 ...