Содержание IPC-610BP-30XF

Страница 1: ...ss underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Страница 2: ...IPC 610F Industrial PC Chassis Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 3: ...r Advantech Co Ltd assumes no respon sibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgments IPC 610F PCA 6113P4R PCA 6114 PCA 6114P...

Страница 4: ...nstalling the power supply and changing the rear cover and window 8 Appendix A Passive Backplanes 9 A 1 PCA 6114 14 slot ISA bus backplane 9 A 2 PCA 6114P4 B 9 ISA 4 PCI 1 CPU slot Backplane 10 A 3 PC...

Страница 5: ...Appendix C Safety Instructions 17 C 1 English 17 C 2 German Wichtige Sicherheishinweise 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 6: ...by two filtered push pull cooling fans to exclude dust and dirt A lockable door protects drives and switches from tampering and foreign particles 1 2 Model List 1 3 Specifications General Constructio...

Страница 7: ...ating temperature 0 50 C 32 122 F Relative humidity 10 95 40 C non condensing Vibration operating Random Vibration 5 500 Hz 1 G RMS Shock operating 10 G acceleration peak 11 ms duration Safety C UL ap...

Страница 8: ...IPC 610F User s Manual 3 42 6 50 43 8 50 48 2 00 173 IPC 610BP 30XF 1 4 Dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 9: ...4 IPC 610F User s Manual 48 2 00 438 50 426 50 173 IPC 610MB 30XF Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 10: ...assis before you install the CPU cards Unplug the power cord from the wall turning off the power switch alone is not sufficient If you are not sure what to do take the job to an experienced profession...

Страница 11: ...lows 1 Detach the hold down clamp by removing the two screws located at each end and lifting it off the chassis See Fig 2 4 2 Insert the rubber buffers provided into the hold down clamp These buffers...

Страница 12: ...out by gently pulling the tab and sliding the filter to the right 3 Slide a new filter in until it snaps into place 4 Close and lock the lockable door Figure 2 6 Replacing the filter 2 5 The Cooling F...

Страница 13: ...C 610F with backplane version Figure 2 9 IPC 610F with motherboard version 2 6 Installing the power supply and changing the rear cover and window Artisan Technology Group Quality Instrumentation Guara...

Страница 14: ...gnals Resistor Signals RN2 SA7 SA10 RP1 SMEMW SMEMR IOW IOR RN5 SA15 SA8 RN3 SBHE LA23 LA17 RN4 SD0 SD7 RN1 LA19 LA16 RN6 SD8 SD15 Appendix A Passive Backplanes A 1 PCA 6114 14 slot ISA bus backplane...

Страница 15: ...10 IPC 610F User s Manual A 2 PCA 6114P4 B 9 ISA 4 PCI 1 CPU slot Backplane Dimensions 260 x 315 mm Unit mm Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 16: ...IPC 610F User s Manual 11 A 3 PCA 6114P7 6 ISA 7 PCI 1 CPU slot Backplane Dimensions 300 x 323 mm Unit mm Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 17: ...12 IPC 610F User s Manual A 4 PCA 6114P10 3 ISA 10 PCI 1 CPU slot Backplane Dimensions 300 x 323 mm Unit mm Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 18: ...IPC 610F User s Manual 13 A 5 PCA 6113P4R 8 ISA 4 PCI 1 PICMG slot Backplane Dimensions 260 x 315 mm Unit mm Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 19: ...14 IPC 610F User s Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 20: ...15 Figure B 1 IPC 610F exploded diagram internal components Appendix B Exploded Diagrams B 1 Exploded Diagram internal components Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SO...

Страница 21: ...PC 610F User s Manual Figure B 2 IPC 610F exploded diagram case components B 2 Exploded Diagram case components Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg...

Страница 22: ...ime disconnect it from the mains to prevent damage from transient overvoltage 12 Never pour any liquid into any opening This could cause fire or electrical shock 13 Never open the equipment For safety...

Страница 23: ...sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden 12 Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeiten in das Ger t gelan g...

Страница 24: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: