background image

ICR-3211

1.7

Product Dimensions

For the dimensions of the product in metal and plastic boxes see the figures below. Note

that all sizes are measured in millimeters.

Figure 7: Basic dimensions of the router box

Figure 8: Basic dimensions of the router box

8

Содержание ICR-3211

Страница 1: ...LTE Industrial Router ICR 3211 USER MANUAL ...

Страница 2: ...ject to change without notice and does not represent a commitment on the part of Advantech Advantech Czech s r o shall not be liable for incidental or consequential damages resulting from the furnish ing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trademarks or other designations in this publication is fo...

Страница 3: ...c situations Information notice Useful tips or information of special interest GPL license Source codes under GPL license are available at https icr advantech cz source code address Advantech Czech s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Document No MAN 0041 EN revision from November 17 2022 Released in the Czech Republic ii ...

Страница 4: ... Slots 13 2 2 Antenna 14 2 3 Ethernet Interfaces 14 2 4 Power Supply 15 2 5 Low Power Mode 16 2 6 Serial Interfaces and I O Port 17 2 7 LED Status Indication 19 2 8 Power Backup Feature 20 2 9 Reset Functions 23 3 First Use 24 3 1 Powering up the Router 24 3 2 Router Configuration 24 4 Technical Parameters 26 4 1 Basic Parameters 26 4 2 Standards and Regulations 27 4 3 Type Tests and Environmental...

Страница 5: ...ICR 3211 Appendix C Regulatory Safety Information 35 Appendix D Related Documents 37 iv ...

Страница 6: ... dimensions of the router box 8 8 Basic dimensions of the router box 8 9 Rotated Wall Mounting Clips 10 10 Removing from the DIN rail 11 11 Label Example 12 12 SIM Cards Insertion 13 13 Ethernet Connector Pinout 14 14 Power connector 15 15 Connection of power supply 15 16 Serial I O connector 17 17 Functional scheme of the binary interface 18 18 Resetting the Router 23 19 Router s Web Interface 25...

Страница 7: ...nnector Pinout Description 14 6 Connection of power connector 15 7 Connection of RS485 17 8 Connection of I O 17 9 Connection of RS232 17 10 Status indication 19 11 Basic parameters 26 12 Standards and regulations 27 13 Type tests and environmental conditions 28 14 Technical parameters of cellular module 29 15 Other technical parameters 30 1 ...

Страница 8: ...n technology which is used to complete the running operation or to send the required data immediately after failure of power supply Configuration of the router may be done via a password protected Web interface Web interface provides detailed statistics about the router s activities signal strength detailed sys tem log etc The router supports the creation of VPN tunnels using IPSec OpenVPN and L2T...

Страница 9: ...ples The router is primarily intended for these four basic situations I Access to the Internet from LAN Figure 1 Access to the Internet from LAN II Backed up access to the Internet from LAN Figure 2 Backed up Access to the Internet 3 ...

Страница 10: ...ICR 3211 III Secure networks interconnection or using VPN Figure 3 Using VPN Tunnel IV Serial Gateway Figure 4 Serial Gateway 4 ...

Страница 11: ...ter 2 4 4 ETH0 ETH1 RJ45 100 MB Ethernet connection for the firts and second LAN see Chap ter 2 3 5 ANT SMA Connector for the main antenna of the cellular module see Chapter 2 2 and Chapter 4 4 for cellular module parameters 6 DIN clip DIN rail clip included as standard accessories see Chapter 1 10 7 Grounding screw M3 Pay attention to proper grounding see Chapter 2 4 8 SIM slots Mini SIM Two SIM ...

Страница 12: ...SIM BIN BOUT ETH RS232 RS485 ICR 3211 2 x 1 x 1 x 2 x 1 x 1 x Table 2 Router versions Figure 6 Router Preview 1 5 Order Codes Order codes overview is shown in the table below Product type Product name Order code Features interfaces ICR 3200 ICR 3211 ICR 3211B LTE module for NAM 2x ETH 1x BI 1x BO 1x RS232 1x RS485 2x SIM reader Table 3 Order Codes Overview 6 ...

Страница 13: ...ty 1 ICR 3211 router 1 pcs 2 DIN holder screwed on the router 1 pcs 3 Wing for wall mounting screwed on the router 2 pcs 4 2 pin terminal block for power supply deployed on the router 1 pcs 5 10 pin terminal block for RS232 RS485 and I O deployed on the router 1 pcs 6 Printed Quick Start Guide 1 pcs Table 4 Contents of package 7 ...

Страница 14: ...nsions For the dimensions of the product in metal and plastic boxes see the figures below Note that all sizes are measured in millimeters Figure 7 Basic dimensions of the router box Figure 8 Basic dimensions of the router box 8 ...

Страница 15: ...oard For whip antennas it is recommended to observe a minimum distance of 6 cm from ca bles and metal surfaces on every side in order to avoid interference When using an external antenna separate from the switchboard it is necessary to fit a lightning conduc tor When mounting a router on sheet steel we recommend using a cable antenna For all cables we recommend to bind the bunch and for this we re...

Страница 16: ...clips Two wall mounting clips are assembled to the router during the production and need to be roteted as shown of Figure 9 There are two wholes on the clip with a diameter of 5 millimeters For detailed information about the mounting dimensions see Chapter 1 7 When mounting the wall mounting clip tighten the screws with max torque of 0 4 Nm Figure 9 Rotated Wall Mounting Clips 10 ...

Страница 17: ...clip tighten the screws with max torque of 0 4 Nm To remove the router from the DIN rail it is necessary to lightly push down the router so that the bottom part of the DIN rail clip hitched to the DIN rail get out of this rail and then fold out the bottom part of the router away from the DIN rail Figure 10 Removing from the DIN rail 11 ...

Страница 18: ...ICR 3211 1 11 Product Label An example of the product label with all the information printed on it is in the figure below Figure 11 Label Example 12 ...

Страница 19: ...w Type of SIM cards Mini SIM 2FF 25 0 x 15 0 x 0 76 mm Inserting the SIM card Always disconnect the router from the power supply before handling the SIM card Unscrew two screws on the SIM card cover and remove the cover To remove an inserted SIM card use the flat end of a spudger or your fingernail press the SIM card slightly into its slot until you hear a click After hearing this click release th...

Страница 20: ...he antenna to the SMA connectors is 0 9 Nm 2 3 Ethernet Interfaces The panel socket of RJ45 is used for Ethernet interface The pinout of the socket is shown in Figure 13 and described in Table 5 Figure 13 Ethernet Connector Pinout Pin Signal mark Description 1 TXD Transmit Data positive pole 2 TXD Transmit Data negative pole 3 RXD Receive Data positive pole 4 5 6 RXD Receive Data negative pole 7 8...

Страница 21: ...y The negative pole of the DC power supply must be at the same voltage reference as the grounding screw If not a voltage difference between these two points might damage the router and only an authorized service center can fix it For correct operation it is necessary that the power source is able to supply a peak current of 1 2 A Unit has to be supplied by a power supply specified as a Limited Pow...

Страница 22: ...r LPM Low Power Mode is a router mode where the router is in sleep mode with minimal power consumption see Chapter 4 1 for the LPM consumption The router can be woken up from this mode by a signal applied to the BIN0 input or after a predetermined period of time Putting the router into LPM mode can be done using the lpm command see Commands and Scripts application note for more details 16 ...

Страница 23: ...router Without termination re sistors signal reflections off the unterminated end of the cable can cause data corruption Termination resistors also reduce electrical noise sensitivity due to the lower impedance Pin Signal mark Description 4 BIN BINARY IN 5 BOUT BINARY OUT Table 8 Connection of I O Pin Signal mark Description 6 RXD IN 7 CTS IN 8 GND GROUND 9 RTS OUT 10 TXD OUT Table 9 Connection of...

Страница 24: ...ICR 3211 The functional scheme of connection for the binary input and binary output is drawn on the picture below Figure 17 Functional scheme of the binary interface 18 ...

Страница 25: ...linking On On On Fast blinking SIM is selected router waits for data connection 4G technology 3G technology 2G technology SIM card problem missing SIM card or PIN code not entered SIM2 Green Green Orange Red Red Blinking On On On Fast blinking SIM is selected router waits for data connection 4G technology 3G technology 2G technology SIM card problem missing SIM card or PIN code not entered USR Gre...

Страница 26: ...nding an SNMP trap Send an SMS This script is going to send an SMS message for when the power supply will reach the defined threshold voltage Following items should be revised in the script destined phone number threshold for minimal power supply voltage content of the SMS message VOLTAGE variable stands for the value of the actual power supply voltage This script monitors the supply voltage and w...

Страница 27: ...age subject and body of the e mail VOLTAGE variable stands for the value of the actual power supply voltage This script monitors the supply voltage and will send an e mail if below the treshold EMAIL_TO xxx organization com Set the destined e mail address THRESHOLD 8 Set the threshold voltage level SENT 0 while true do VOLTAGE status sys awk Voltage print 4 if THRESHOLD lt VOLTAGE then SENT 0 elif...

Страница 28: ...minimal power supply voltage This script monitors the supply voltage and will send an SNMP trap if below the treshold SNMP_IP 192 168 1 1 Set SNMP destinated IP address OID 1 2 3 4 5 6 7 8 Set the OID THRESHOLD 8 Set the threshold voltage level SENT 0 while true do VOLTAGE status sys awk Voltage print 4 if THRESHOLD lt VOLTAGE then SENT 0 elif SENT eq 0 then Sending the SNMP trap snmptrap c public...

Страница 29: ...configuration of the router press and hold the RST button for more than 4 seconds After that the PWR LED turns off and on again We recommend holding the RST button for 1 second after turning on the PWR LED Emergency Factory Reset If the router cannot boot up due to the incorrect configu ration turn off the router disconnect the power supply Then push and hold the RST button turn on the router and ...

Страница 30: ...outer for its default password1 Log in to the web interface by the root user and his password If logged in successfully the user will have access to the router web interface see Figure 19 See the configuration manual 2 of the router for a detailed description and examples of the router configuration After logging on to the device for the first time we strongly recommend changing the default passwo...

Страница 31: ...ICR 3211 Figure 19 Router s Web Interface A detailed description of the router settings in the web interface can be found in the configura tion manual of the router 25 ...

Страница 32: ...ing 2000 m 70 kPa Degree of protection IP30 Supply voltage 9 to 36 V DC Battery for RTC CR1225 Consumption 9 V Idle Average Peak Sleep mode 2 3 W 3 8 W 5 4 W 100 mW Dimensions of device 31 2 x 94 x 129 mm 1 23 x 3 7 x 5 08 DIN rail clip dimensions DIN 35 mm EN 60715 Weight Metal box 480 g 1 05 lbs Antenna connectors 1x SMA for LTE 50 Ω User interface 2x ETH SERIAL I O Ethernet RJ 45 10 100 Mbit s ...

Страница 33: ... 303 413 EMC EN 301 489 1 EN 301 489 19 EN 301 489 52 EN 61000 6 2 EN 61000 6 4 FCC 15 107 Class B FCC 15 109 Class B IC Safety IEC 62368 1 2014 Transportation EN 45545 2 Railway EN 50155 A1 OT4 ST1 H1 Cat 1 Class B S3 C2 L4 PD1 K2 PC2 Carrier approvals Verizon AT T National FCC IC CE UKCA compliant Environmental REACH RoHS3 and WEEE compliant Table 12 Standards and regulations 27 ...

Страница 34: ...ed cab 2 kV crit A RF conducted EN 61000 4 6 All ports 10 V m crit A 0 15 80 MHz Radiated emission EN 55032 Enclosure Class B Conducted emission EN 55032 DC power ports Ethernet ports Class B Class B Dry heat EN 60068 2 2 MIL STD 810G SAE J1455 75 C 40 rel humidity Cold EN 60068 2 1 MIL STD 810G SAE J1455 40 C Damp heat EN 60068 2 78 MIL STD 810G SAE J1455 95 rel humidity 40 C Vibration EN 60068 2...

Страница 35: ...9 1900 MHz LTE bit rates 375 Kbps DL 375 Kbps UL EDGE parameters Supported frequencies 850 MHz 900 MHz 1800 MHz 1900 MHz EDGE bit rates 296 Kbps DL 236 8 Kbps UL GPRS parameters Supported frequencies 850 MHz 900 MHz 1800 MHz 1900 MHz GPRS bit rates 107 Kbps DL 85 6 Kbps UL Table 14 Technical parameters of cellular module Antenna Requirements VSWR 2 1 Antenna input impedance response as function of...

Страница 36: ...rameters Other technical parameters CPU Cortex A8 1 GHz 2 DMIPS per MHz Flash memory Available memory space 1862 MB 2x 256 MB FW 512 MB User data storage 838 MB Space for Router Apps RAM 512 MB Table 15 Other technical parameters 30 ...

Страница 37: ... the neighbouring cells have a similar signal strength you will need to use a directional antenna For proper operation the signal levels have to be good Try to enable automatic ping from the router which will check the connection when there are no data running and in the case of a failed ping restart the connection This can be done on the Mobile WAN Configuration page in the router in the Check co...

Страница 38: ...e with router s IP address You can verify a Firewall by accessing remotely to the router s Web interface The operator may not provide the address of DNS server and without DNS server s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the System Log DynDNS daemon started Error resolving hostname no such file or directory Connect to DynDNS server ...

Страница 39: ...ers only You can use SFTP on all routers to transfer files to from the router If having troubles with FTP on v2 routers make sure you have FTP enabled Configuration section Services FTP Then you can connect with any client on port 21 with name and password same as for the Web interface If having troubles with SFTP make sure you have SSH enabled Configuration section Services SSH Then you can conne...

Страница 40: ...eu Web www advantech com Customer Support for NAM Advantech B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 1 800 346 3119 Monday Friday 7 a m to 5 30 p m CST Fax 1 815 433 5109 E mail support advantech bb com Web www advantech bb com Customer Support for Asia Phone 886 2 2792 7818 1299 Monday Friday 9 a m to 5 30 p m UTC 8 Fax 886 2 2794 7327 E mail icg support advantech com tw Web www ad...

Страница 41: ... expose the router to extreme ambient conditions Protect the router against dust moisture and high temperature Only routers with appropriate certification and labelling should be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the...

Страница 42: ...inimize the environmental impact This product contains high quality materials and components which can be recycled At the end of it s life this pro duct MUST NOT be mixed with other commercial waste for disposal The device contains a battery Re move the battery from the device before disposal The battery in the device needs to be disposed of apart accordingly Check the terms and conditions of your...

Страница 43: ...d Documents 1 Quick Start Guide for ICR 3200 Platform 2 Configuration Manual for ICR 3200 Platform EP Product related documents and applications can be obtained on Engineering Portal at https icr advantech cz download address 37 ...

Страница 44: ...lies with Radio Equipment Regulations 2017 S I 2017 No 1206 We Advantech Czech s r o declare that the radio equipment narrated in this user s manual complies with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following internet address icr advantech cz eudoc ...

Отзывы: