ICR-2412
4.3
Type Tests and Environmental Conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure
CD
±
6 kV, L3
RF field AM
modulated
EN 61000-4-3
Enclosure
20 V/m, 80 MHz-1 GHz, LX
10 V/m, 1 GHz-6 GHz, L3
Fast transient
EN 61000-4-4
DC port
ETH - FTP
Binary input
Binary output
RS232
RS485
±
1 kV, 5/50 Tr/Th ns, 100 kHz, L2
±
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
±
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
±
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
±
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
±
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
Surge
EN 61000-4-5
ETH
RS485
±
1 kV, 1.2/50(8/20) Tr/Th us, L2
±
1 kV, 1.2/50(8/20) Tr/Th us, L2
RF conducted
EN 61000-4-6
DC port
ETH
I/O ports
RS232
RS485
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
Radiated emission
EN 55032
Enclosure
Class B, 30 MHz-1 GHz, 1 GHz-6 GHz
Conducted
emission
EN 55032
DC power port
Ethernet ports
Serial ports
RS232
RS485
Class B, 150 kHz-30 MHz
Class B, 150 kHz-30 MHz
Class B, 150 kHz-30 MHz
Class B, 150 kHz-30 MHz
Class B, 150 kHz-30 MHz
Dry heat
EN 60068-2-2
Operating
Storage
Test Bb, s75
◦
C
Test Bd, ope85
◦
C
Cold
EN 60068-2-1
Operating
Storage
Test Ab, storage -40
◦
C
Test Ad, operation -40
◦
C
Variation of
temperature
EN 60068-2-14
Test Nb, -40
◦
C / +75
◦
C, 3h/3h, 2 cycles, 3 K/min
Dry heat, cyclic
EN 60068-2-30
+55
◦
C / +25
◦
C, rel. humidity 95 %, 6 h-6 h
Table 11: Type Tests and Environmental Conditions
25
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: [email protected] — www.lucom.de
www
.lucom.de