117
EKI-9500 Series User Manual
4.3.10.3
PoE Port Statistics
Use the PoE Port Statistics page to view PoE interface statistical information.
To access this page, click
System
>
PoE
>
PoE Port Statistics
.
Figure 4.120 System > PoE > PoE Port Statistics
The following table describes the items in the previous figure.
Current Consump-
tion
The interface port output current(milliAmp) drawn by device.
Detection Status
The status of the port as a provider of PoE. Such devices are referred
to as PSE. The status can be one of the following:
Disabled: The PSE is disabled.
Delivering Power: The PSE is delivering power.
Fault: The PSE has experienced a fault condition.
Test: The PSE is in test mode.
Other Fault: The PSE has experienced a variable error condition.
Searching: The PSE is transitioning between states.
Requesting Power: The PSE is currently not able to deliver
power because power is unavailable to the port.
Fault Indication
The error when PSE port is in fault status, which can be one of the fol-
lowing:
None: PSE port is not in any error state.
MPS Absent: PSE port has detected absence of main power
supply.
Short: PSE port has detected a short circuit condition.
Overload: PD connected to PSE port tried to draw more power
than permissible by the hardware.
Power Denied: PSE port has been denied power due to adminis-
trative action or shortage of power.
Refresh
Click
Refresh
to update the screen.
Edit
Click
Edit
to edit the selected entries.
Edit All
Click
Edit All
to apply same setting to all interfaces.
Item
Description
Item
Description
Interface
The interface associated with the rest of the data on the page.
Overload Counter
Number of times there has been a power overload. Power overload
occurs when a powered device connected to a port tries to draw more
power than permissible by the hardware.
Short Counter
Number of times there has been a short circuit condition.
Power Denied
Counter
Number of times the powered device has been denied power. Power is
denied due to administrative action or shortage of power.
MPS Absent Coun-
ter
Number of times power has stopped because the powered device was
not detected.
Invalid Signature
Counter
Number of times an invalid signature was received. Signature detec-
tion is a stage in detecting the presence of a powered device, where a
resistence value on the powered device is expected to be found within
a particular range.