EKI-9500 Series User Manual
114
4.3.9.4
Last Password
Use the Last Password Result page view information about the last attempt to set a
user password. If the password set was unsuccessful, a reason for the failure is
given.
To access this page, click
System
>
Passwords
>
Last Password
.
Figure 4.116 System > Passwords > Last Password
The following table describes the items in the previous figure.
4.3.9.5
Reset Passwords
Use the Reset Passwords page to reset all system login passwords to factory default
values. When you click
Reset
, the reset action is initiated.
Minimum Character
Classes
This minimum number of character classes, defined as the various
password strength categories listed above, that must be met in order
for a password to be considered valid. It is permissible, therefore, to
define strength checking criteria for each of the different types of con-
ditions, but only require a valid password to meet some of them. The
number of these character classes that must be met is specified by
this value.
Exclude Keyword
Name
The list of keywords that a valid password must not contain. Excluded
keyword checking is case-insensitive. Additionally, a password cannot
contain the backwards version of an excluded keyword. For example,
if pass is an excluded keyword, passwords such as 23passA2c, ssap-
word, and PAsSwoRD are prohibited. Use the plus and minus buttons
to perform the following tasks:
To add a keyword to the list, click
button, type the word to
exclude in the Exclude Keyword Name field, and click
Submit
.
To remove a keyword from the list, click
button associated
with the keyword to remove and confirm the action.
To remove all keywords from the list, click
button in the
header row and confirm the action.
Submit
Click
Submit
to save the values and update the screen.
Refresh
Click
Refresh
to update the screen.
Cancel
Click
Cancel
to restore default value.
Item
Description
Item
Description
Last Result
Displays information about the last (User/Line/Enable) password con-
figuration result. If the field is blank, no passwords have been config-
ured on the device. Otherwise, the field shows that the password was
successfully set or provides information about the type of password
configuration that failed and why it could not be set.
Strength Check
Displays Enabled if Strength Check is applied in last password
change, otherwise it displays Disabled.
Refresh
Click
Refresh
to update the screen.
Содержание EKI-9512-C0IDW10E
Страница 1: ...User Manual EKI 9500 Series Full Managed Ethernet Switches...
Страница 20: ...Chapter 1 1Product Overview...
Страница 28: ...Chapter 2 2Switch Installation...
Страница 38: ...Chapter 3 3Configuration Utility...
Страница 43: ...Chapter 4 4Managing Switch...