Product Warranty (2 years) 
 

Advantech warrants to you, the original purchaser, that each of its products will be free from 
defects in materials and workmanship for two years from the date of purchase. 
 
This warranty does not apply to any products which have been repaired or altered by persons 
other than repair personnel authorized by Advantech, or which have been subject to misuse, 
abuse, accident or improper installation. Advantech assumes no liability under the terms of 
this warranty as a consequence of such events. 
 
Because of Advantech’s high quality-control standards and rigorous testing, most of our 
customers never need to use our repair service. If an Advantech product is defective, it will be 
repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you 
will be billed according to the cost of replacement materials, service time and freight. Please 
consult your dealer for more details. 
 
If you think you have a defective product, follow these steps: 
 
1.  Collect all the information about the problem encountered. (For example, CPU speed, 

Advantech products used, other hardware and software used, etc.) Note anything 
abnormal and list any onscreen messages you get when the problem occurs. 

2.  Call your dealer and describe the problem. Please have your manual, product, and any 

helpful information readily available. 

3.  If your product is diagnosed as defective, obtain an RMA (return merchandize 

authorization) number from your dealer. This allows us to process your return more 
quickly. 

4.  Carefully pack the defective product, a fully-completed Repair and Replacement Order 

Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable 
container. A product returned without proof of the purchase date is not eligible for 
warranty service. 

5.  Write the RMA number visibly on the outside of the package and ship it prepaid to your 

dealer. 

iii                                                

Содержание EKI-7529MI

Страница 1: ...EKI 7529MI EKI 7529MI ST 8 2 100 FX Port Unmanaged Industrial Ethernet Switch User Manual ...

Страница 2: ...prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of ...

Страница 3: ...ement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and de...

Страница 4: ...nd if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com support...

Страница 5: ...thing over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service pe...

Страница 6: ...om damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components ...

Страница 7: ... Figure 2 1 Front View of EKI 7529MI EKI 7529MI ST 9 Figure 2 2 Side View of EKI 7529MI EKI 7529MI ST 10 Figure 2 3 Rear View of EKI 7529MI EKI 7529MI ST 11 Figure 2 4 Top View of EKI 7529MI EKI 7529MI ST 11 2 3 Mounting 12 2 3 1 Wall mounting 12 Figure 2 5 Combine the Metal Mounting Kit 12 2 3 2 DIN rail Mounting 13 Figure 2 6 Installation to DIN rail Step 1 13 Figure 2 7 Installation to DIN rail...

Страница 8: ...EKI 7529MI_7529MIST_Manual_ed4 viii ...

Страница 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER ...

Страница 10: ... through a relay output for notifying user 1 1 3 Flexible Mounting EKI 7529MI EKI 7529MI ST is extremely compact 79 x 152 x 105 mm and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 4 Advanced Protection EKI 7529MI EKI 7529MI ST supports up to 3 000 VDC EFT protection for power line and also supports 4 000VDC ESD protection for Ethernet ports Wi...

Страница 11: ...rts MDI MDI X auto crossover Provides broadcast storm protection Supports surge protection EFT 3 000 VDC for power line Supports 4 000 VDC ESD protection for Ethernet Supports 12 48 VDC power input Provides flexible mounting DIN rail Wall Mounting Supports Wide range operating temperature from 40 75 EKI 7529MI EKI 7529MI ST Provides Port 1 and port 2 work on 10Mbps transmission Provides Broadcast ...

Страница 12: ...w terminal power relay LED Indicators Unit PWR1 PWR2 P Fail TX port Link Active Duplex Collision FX port Link Active DIP Switch DIP1 10Mbps Full Force Auto Negation DIP2 Broadcast Storm filter Power Power Consumption Max 6 7 Watts Power Input 2 x Unregulated 12 48 VDC Fault Output 1 Relay Output Inrush Current 200 24VDC Mechanism Dimensions WxHxD 79 x 152 x 105 mm Enclosure IP30 Metal shell with s...

Страница 13: ...289518 hours EKI 7529MI 289329 hours EKI 7529MI ST Certifications Safety UL 508 Class 1 Division 2 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN55022 EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 EN61000 6 2 4 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Future Release 5 Chapter1 ...

Страница 14: ...ation Industrial Communication CD ROM with User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 7529MI EKI 7529MI ST Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Страница 15: ...7 Chapter2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Fiber Optic Network Connection z Power Connection CHAPTER ...

Страница 16: ...input 1 and 2 are both active or no power input On Connected to 100 Mbps network Flashing Data is transmitting or receiving Link Active 9 10 Green Off Not connected to 100 Mbps network On Connected to network Flashing Networking is active Link Active 1 8 Green Off Not connected to network On Ethernet port full duplex Flashing Collision of packets occurs Duplex Collision 1 8 Yellow Off Ethernet por...

Страница 17: ...2 2 Dimensions units mm Figure 2 1 Front View of EKI 7529MI EKI 7529MI ST 9 Chapter2 ...

Страница 18: ...Figure 2 2 Side View of EKI 7529MI EKI 7529MI ST EKI 7529MI_7529MIST_Manual_ed4 10 ...

Страница 19: ...Figure 2 3 Rear View of EKI 7529MI EKI 7529MI ST Please refer to page 19 for pin assignment Figure 2 4 Top View of EKI 7529MI EKI 7529MI ST 11 Chapter2 ...

Страница 20: ...included mounting kit Then hang on the EKI 7529MI EKI 7529MI ST to the nails on the wall First use the screws included in the package to combine the EKI 7529MI EKI 7529MI ST and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit EKI 7529MI_7529MIST_Manual_ed4 12 ...

Страница 21: ...kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 7529MI EKI 7529MI ST to the DIN rail with angle of inclination See figure 2 6 Figure 2 6 Installation to DIN rail Step 1 13 Chapter2 ...

Страница 22: ...Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 EKI 7529MI_7529MIST_Manual_ed4 14 ...

Страница 23: ...529MI EKI 7529MI ST provides 2 x SC or ST type fiber ports for difference fiber type EKI 7529MI EKI 7529MI ST supports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X port on the switch to any device such as a switch bridge or router 2 5 Power Connection The EKI 7529MI EKI 7529MI ST supports dual 12 48 VDC power inputs and power fail relay output Figure 2 8...

Страница 24: ...EKI 7529MI_7529MIST_Manual_ed4 16 Troubleshooting CHAPTER ...

Страница 25: ...h of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is plugged in user may have a problem with power cord Then chec...

Страница 26: ...EKI 7529MI_7529MIST_Manual_ed4 18 Pin Assignment Wiring APPENDIX ...

Страница 27: ...Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A 19 ...