M
ANAGING
S
WITCH
131
4.10. Diagnostics
Through the Diagnostics function configuration of settings for the switch diagnostics is
available.
4.10.1 Cable Diagnostics
The Cable Diagnostics page allows you to select the port for applying a copper test.
To access this page, click
Diagnostics
>
Cable Diagnostics
.
Figure 4-104.
Diagnostics > Cable Diagnostics
The following table describes the items in the previous figure.
The ensuing table for
Test Result
settings are informational only: Port, Channel A, Cable
Length A, Channel B, Cable Length B, Channel C, Cable Length C, Channel D and Cable
Length D.
Table 4-102.
Diagnostics > Cable Diagnostics
Item
Description
Port
Click the drop-down menu to select a pre-defined port for diagnostic
testing. Giga ports are displayed with a channel A to D designation.
Copper Test
Click
Copper Test
to display the test result for the selected port.