Make sure to separate input and output wiring.
Label all wiring and cabling to the various devices for more effective manage-
ment and servicing.
2.5.3 Grounding the Device
Electromagnetic Interference (EMI) affects the transmission performance of a device.
By properly grounding the device to earth ground through a drain wire, you can setup
the best possible noise immunity and emissions.
Figure 2.8 Grounding Connection
Note!
Routing communications and power wiring through the same conduit
may cause signal interference. To avoid interference and signal degra-
dation, route power and communications wires through separate con-
duits.
Caution!
Do not disconnect modules or cabling unless the power is first switched
off.
The device only supports the voltage outlined in the type plate. Do not
use any other power components except those specifically designated
for the switch device.
Caution!
Before connecting the device properly ground the device. Lack of a
proper grounding setup may result in a safety risk and could be hazard-
ous.
Caution!
Do not service equipment or cables during periods of lightning activity.
Caution!
Do not block air ventilation holes.
Drain Wire with Lug
Connection to
Grounding Point
Содержание EKI-5624PI
Страница 1: ...User Manual EKI 5729PI EKI 5624PI ProView Series Ethernet Switches...
Страница 10: ...Chapter 1 1 Product Overview...
Страница 17: ...Chapter 2 2 Switch Installation...
Страница 30: ...Chapter 3 3 Configuration Utility...
Страница 40: ...Chapter 4 4 Managing Switch...
Страница 52: ...EKI 5729PI EKI 5624PI User Manual 43 Temperature Celsius Figure 4 12 Setting Modbus TCP Idle Time...
Страница 63: ...54 EKI 5729PI EKI 5624PI User Manual...