background image

 

EKI-4524RI 

24-port 10/100TX + 2-port 100 
Mini-GBIC Ethernet Switch 
with AC/DC Power Input and 
Wide Operating Temperature 

 

EKI-4524ARI 

24-port 10/100TX + 2-port 100 
Mini-GBIC Ethernet Switch 
with Wide Operating 
Temperature 

 
 

User Manual

Содержание EKI-4524ARI

Страница 1: ... port 10 100TX 2 port 100 Mini GBIC Ethernet Switch with AC DC Power Input and Wide Operating Temperature EKI 4524ARI 24 port 10 100TX 2 port 100 Mini GBIC Ethernet Switch with Wide Operating Temperature User Manual ...

Страница 2: ... translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements All other product names or trademarks are pro...

Страница 3: ...ent materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example network speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and ...

Страница 4: ... and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com suppo...

Страница 5: ...thing over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service pe...

Страница 6: ...cautions to protect yourself from harm and the products from damage 1 To avoid electrical shock always disconnect the power from your equipment chassis before you work on it 2 Disconnect power before making any configuration changes EKI 4524RI ARI_User Manual vi ...

Страница 7: ... the 19 rack 10 2 4 Network Connection 11 2 5 Connection to a Fiber Optic Network 11 Figure 2 5 Transceiver to the SFP Slot 11 Figure 2 6 Transceiver Inserted 12 Figure 2 7 LC Connector to the Transceiver 12 Figure 2 8 Removing the LC Connector 13 Figure 2 9 Pulling out from the Transceiver 13 2 6 Wiring the Power Input 14 Table 2 2 Terminal Block Pinouts 14 Figure 2 10 10 position Cross Screw Ter...

Страница 8: ...EKI 4524RI ARI_User Manual viii ...

Страница 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER ...

Страница 10: ... hot swappable and plug and play Also the fact that the switch has two of these slots means that the network manager can for example have one 10km transceiver in one slot and one 110km in the other 1 1 2 High Speed Transmissions The EKI 4524RI 4524ARI includes a switch controller that can automatically sense transmission speeds 10 100 Mbps The RJ 45 interface can also be auto detected so MDI or MD...

Страница 11: ... and Forward Switching Architecture Back plane Switching Fabric 5 2Gbps 4Mbits Packet Buffer 8K MAC Address Table Power Supply EKI 4524RI 100 240 VAC VDC Power Input EKI 4524ARI 12 48 VDC Power Input Case Installation IP 30 Protection 19 inch Rack Mount Design Provides EFT protection 4 000 VDC for power line Supports 8 000 VDC Ethernet ESD protection 3 Chapter1 ...

Страница 12: ...4ARI LED Indicators System PWR 10 100TX LNK ACT Speed SFP Link Activity Power Power Consumption EKI 4524RI 16 1 Watts max 110 VDC 17 5 Watts max 110 VAC EKI 4524ARI 13 9 Watts max 48 VDC Power Input EKI 4524RI 100 240 VAC 50 60Hz 20 100 240 VDC 20 EKI 4524ARI 12 48 VDC Relay Alarm 1 Relay Output Mechanism Dimensions WxHxD 440 x 44 x 280 mm Enclosure IP30 metal shell with solid mounting kits Mounti...

Страница 13: ...orage Humidity 5 95 non condensing Certifications Standard Meets IEC 61850 3 IEEE 1613 EMC FCC Class A CE EN61000 6 4 CE EN61000 6 2 CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field Freefall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 5 Chapter1 ...

Страница 14: ...Fast Ethernet Switch 1 x eAutomation Industrial Communication CD ROM and User manual 2 x Rackl Mounting Bracket and Screws 1 x EKI 4524RI 4524ARI Startup Manual 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Страница 15: ...7 Chapter2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Connection to a Fiber Optic Network z Power Connection CHAPTER ...

Страница 16: ...l LED Color Description On Power input is active PWR Green Off Power input is inactive On Connected to network Flashing Networking is active LNK ACT Port 1 26 Green Off Not connected to network On Connected to network at speed of 100Mbps 10 100 Port 1 24 Green Off 10Mbps or link down Rear Panel LED Color Description On Power input is active PWR Green Off Power input is inactive On Connected to net...

Страница 17: ...2 2 Dimensions units mm Figure 2 1 EKI 4524RI Mechanical Dimensions Figure 2 2 EKI 4524ARI Mechanical Dimensions 9 Chapter2 ...

Страница 18: ...ing bracket to the other side of the Switch Figure 2 3 Attach mounting brackets with screws 2 After attaching the mounting brackets position the EKI 4524RI 4524ARI in the rack by lining up the holes in the brackets with the appropriate holes on the rack Secure the Switch to the rack by a screwdriver with the rack mounting screws Figure 2 4 Mount the switch in the 19 rack Note For proper ventilatio...

Страница 19: ...o the network segment with single or multi mode fiber You can choose appropriate mini GBIC transceiver to plug into the slot Make sure the transceiver is aligned correctly and then slide the transceiver into the SFP slot until a click is heard You can use proper multi mode or single mode fiber according to the used SFP transceiver With fiber optic it transmits speed up to 1 00 Mbps and you can pre...

Страница 20: ...Figure 2 6 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver Figure 2 7 LC Connector to the Transceiver EKI 4524RI ARI_User Manual 12 ...

Страница 21: ...teps shown below First press the latches of the LC connector and pull it out from the transceiver Figure 2 8 Removing the LC Connector Second push down the transceiver handle and pull it out by the plastic handle Figure 2 9 Pulling out from the Transceiver 13 Chapter2 ...

Страница 22: ...sitive point of the DC power source 4 GND Grounding pin 5 NA Not available 6 NA Not available 7 NA Not available 8 Alarm Contact Used for wiring to an external self powered warning device 9 NA Not available 10 Alarm Contact Used for wiring to an external self powered warning device 1 Before wiring make sure the power source is disconnected 2 Prepare the bare wires or ring lugs for power connection...

Страница 23: ... Pin 3 4 P Fail Contacts Pin 1 2 NC Figure 2 11 Power Contacts of the Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosing Note Use Copper Conductors Only 60 75 C tightening to 5 lb in The wire gauge for the terminal block should be in the range between 12 24 AWG 15 Chapter2 ...

Страница 24: ...m device for warning purposes EKI 4524RI P Fail Alarm Wiring The fail safe relay alarm contacts of EKI 4524RI are labeled as 8 and 10 as the figure shown below 20mA 250VDC P Fail 7 9 8 10 Figure 2 12 Fail Safe Relay Contacts of EKI 4524RI EKI 4524ARI P Fail Alarm Wiring The fail safe relay alarm contacts of EKI 4524ARI are labeled as 3 and 4 as the figure shown below Figure 2 13 Fail Safe Relay Co...

Страница 25: ...17 Troubleshooting CHAPTER ...

Страница 26: ...nnection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light up when the power cord is plugged in you may have a problem with power cord Then check for loose...

Страница 27: ...19 Pin Assignment Wiring APPENDIX ...

Страница 28: ...ppendix A Pin Assignments Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A EKI 4524RI ARI_User Manual 20 ...

Страница 29: ...21 Compatible SFP Transceivers APPENDIX ...

Страница 30: ...Mode Transmission Distance 1 AVAGO AFBR 5710PZ 550m 2 APAC LM28 C3S TC N 550m 3 HOATECH HTI8512 X5ATO 550m 4 SPACE SHUTTLE S56L S85 6L N Multi mode 550m SP GB LX 10km SP GB ELX 20km 5 LuminentOIC SP GB XD 50km 6 AVAGO AFCT 5710PZ 10km 7 APAC LS38 C3M TC N 20km 8 SPACE SHUTTLE S56L L13 6L N Single mode 10km EKI 4524RI ARI_User Manual 22 ...

Отзывы: