EKI-1526(TI) | 1528(TI) User Manual
36
The EKI-1526(TI) | 1528(TI) provide Multi-access function through an Ethernet con-
nection path, allowing a maximum of five connections to open one serial port simulta-
neously. In this mode, all connections use the same serial setting. If one serial setting
within this configuration is configured differently, the data communication will not
function correctly.
Figure 4.2 Configuring Virtual COM Mode
The Host Idle Timeout setting monitors the connection between the host and the
device. If the Host Idle Timeout setting time is reached, the device server will release
the resources allocated to the port mapping. This prevents a stalled host from affect-
ing the connective device.
The Multi-access function has two modes. One is
Normal mode
and the other is
Round-Robin mode
.
4.2.1
Normal mode
By disabling the Response Timeout parameter, the EKI-1526(TI) | 1528(TI) Series
will operate in normal mode. When multiple hosts simultaneously open the serial
port, only the first connected host has management control; the remaining connec-
tions only have a data communication function. Each serial port supports up to five
simultaneous connections, so multiple hosts can transmit/receive data to/from the
same serial port simultaneously. Every host can transmit data to the same serial port,
and the EKI-1526(TI) | 1528(TI) Series will also transmit data to every hosts. When
the multiple hosts transmit data to the same serial port at the same time, the received
data from Ethernet and the outputs of serial port are mixed. When the EKI-1526(TI) |
1528(TI) Series receives data from serial port, the data will also be transmitted to the
connected hosts simultaneously.
4.2.2
Round-Robin mode
By enabling the
Response Timeout
parameter, the EKI-1526(TI) | 1528(TI) Series
operates in “Round-Robin mode”. Each serial port supports up to five simultaneous
connections allowing hosts to simultaneously transmit/receive data to/from the same
serial port. Every host can simultaneously transmit data to the same serial port, EKI-
1526(TI) | 1528(TI) Series processes the data in the order arrived. The EKI-1526(TI)
| 1528(TI) Series processes the first host’s request and replies. The serial device
server determines the end of the serial acknowledgement through a response time-
out. When EKI-1526(TI) | 1528(TI) serial device server does not receive a response
from the serial port after a response timeout query, the device replies with an
acknowledgement and then processes the next host request.
With an increased number of hosts, response time may be lengthy, increasing the
period of the Response Timeout.
Frame Break
is therefore an important parameter
for Round Robin mode. The parameter is a smart method of reducing ineffective wait-
ing periods and streamlining the transmission process.
Содержание EKI-1526
Страница 1: ...User Manual EKI 1526 I TI EKI 1528 I TI 8 16 port RS 232 422 485 Serial Device Server Rackmount...
Страница 13: ...Chapter 1 1Overview...
Страница 17: ...Chapter 2 2Getting Started...
Страница 27: ...Chapter 3 3Utility Configuration...
Страница 46: ...Chapter 4 4Selecting An Operating Mode...
Страница 54: ...Chapter 5 5Setting Up Virtual COM Redirector...
Страница 63: ...Chapter 6 6Web Configuration...
Страница 84: ...Chapter 7 7Telnet...
Страница 94: ...Chapter 8 8TCP and UDP Port Numbers...