Integrated UPS
64 / 81
DLT-V4108 Manual, V01 Prelim
Advantech-DLoG
17.
Integrated UPS
The DLT-V4108 has an integrated uninterrupted power supply (UPS). The battery pack (lithium-
ion technology) of the UPS is located inside of back cover.
Only the manufacturer and its authorized service centers may open the DLT-V4108 device
and insert/remove the battery pack.
WARNING
Personal injury from battery packs: Short-circuit, fire, chemical burns, toxic substances.
The integrated UPS battery packs can ignite if the DLT-V4108 is handled improperly (risk of
fire), cause chemical burns or release toxic substances.
−
Use care when handing the DLT-V4108.
−
Do not damage the DLT-V4108; otherwise lithium-ion battery packs could be damaged.
−
Do not allow the DLT-V4108 to come into contact with fire.
−
Provide sufficient ventilation.
−
Observe the specific IP protection class.
−
Only use the DLT-V4108 within the permitted temperature and humidity range.
To charge the battery packs of the integrated UPS:
−
Connect the properly installed DLT-V4108 to the main supply voltage.
−
Provide for sufficient ventilation of the DLT-V4108 when charging the battery packs.
Performance specifications Li-ion rechargeable battery pack; 2 cells of UR14650R (900 mAh)
Bridging time
Typically 15 minutes (when battery pack is fully charged)
Charging time
2 h (fully recharge a completely discharged battery pack)
UPS charging temperature
0 to +45 °C (ambient temp.)
UPS discharging
temperature
-20 to + 50 °C
Output power
6.48 W
Battery voltage
7.2 V