background image

Product Overview

Hardware Installation

1

Terminal Blocks

Terminal

Description

V2-

Power Input 2 (DC Ground)

V2+

Power Input 2 (12 to 48VDC)

P-Fail

Power Fault Relay

P-Fail

Power Fault Relay 

V1-

Power Input 1 (DC Ground)

V1+

Power Input 1 (12 to 48VDC)

LED Status

3

LED

Status

Description

SYS

Green

System is operating normally

Off

No Power / system crash / 

operation initiating

PWR1

Green

Powered up

  

Off

Power down or not installed

PWR2

Green

Powered up

Off

Power down or not installed

P-Fail

Solid Red

When PW1 or PW2 is dis-

connected, the LED lights.

Off

When PW1 and PW2 is con-

nected, the LED is off.

LOOP

Detection

Solid Red

When loop detected, the 

LED lights.

Off

No loop detected.

R.M.

Solid 

Green

An active switch within the 

ring is a designated ring 

master.

Off

No ring master determined in 

current ring.

Ring Fail

Solid Red

A ring port within the ring 

loop is identified has having 

a ring ID within a second ring 

loop.

Off

No ring ports having a ring ID 

within a secondary ring

loop are detected.

Temp

Solid Red

IC sensor detects a tempera-

ture range exceeding set

temperature range.

Off

IC sensor detects normal 

operating temperature.

LED

Status

Description

SFP LED

Solid Green

SFP or GBIC plug-in and link 

up.

Blink Green

Packet transmit and receive.

Off

SFP or GBIC plug-out or link 

down.

PoE

(SEGP528)

Solid Green

Connect to PD and supply 

power.

Blink Green

Not applicable.

Off

Disconnect from PD and No 

supply Power.

LNK/ACT

Solid Green

Current link speed is 1000M.

Blink Green

Packet transmit and receive.

Off

No link.

Solid Amber

Current link speed is 

100/10M.

Blink Amber

Packet transmit and receive.

Off

No link.

Solid Green

Connect to PD and supply 

power.

2

Wire Gauge:  12-24 AWG (3.31 - 0.205 mm2).

Torque:            7lb-in.

NOTE

: P-Fail Relay is closed if both power input ports 

are powered. The default is open.

System LED

Panel

100/1000

SFP Ports

10/100/1000

Ethernet Ports

10/100/1000

Ethernet Ports

SFP LEDs

Console Serial

Port (Back)

GND (Back)

Power (Back)

Rack Mounting

System

1. Align the rack mount brackets with the holes on the   

    switch

2. Secure the rack mount brackets with the provided    

    screws

3. Align the switch with the posts on the rack cabinet

SFP

Отзывы: