iMcV-Giga-MediaLinX
7
UNMANAGED MODULES
Before installing, configure the iMcV-Giga-MediaLinX TX/SFP modules for
desired features. The table below indicates the available features and settings
for the iMcV-Giga-MediaLinX TX/SFP modules. After configuring desired
settings, install the module and connect appropriate cables (see
Installing
iMcV-Giga-MediaLinX TX/SFP
section for more information).
DIP Switch on S1
Feature
Default Setting
1
TX Auto Negotiation
ON
2
TX Port-HDX (ON) or FDX (OFF)
OFF
3
TX Port-100 (ON) or 10 (OFF)
OFF
4
TX Port-1000
ON
5
TX LinkLoss (TXLL)
OFF
6
FiberAlert
OFF
7
Selective Advertising
OFF
8
FX LinkLoss (FXLL)
OFF
9
FX Auto Negotiation
ON
10
Factory Configured—Do Not Change
OFF