background image

User Manual

ARS-P2800 Series

Passenger Information System 
Computer for Railway 
Applications

Содержание ARS-P2800 Series

Страница 1: ...User Manual ARS P2800 Series Passenger Information System Computer for Railway Applications...

Страница 2: ...the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an A...

Страница 3: ...r primary concern Here is a guide to Advantech s cus tomer services To ensure you get the full benefit of our services please follow the instructions below carefully Technical Support We want you to g...

Страница 4: ...the carrier Retain the shipping carton and packing material for inspection by the carrier After inspection we will make arrangements to repair or replace the unit Order information Declaration of Conf...

Страница 5: ...ified service personnel 14 If one of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetrated into the equipment The equip...

Страница 6: ...2 Ne jamais verser de liquide dans les ouvertures de ventilation cela pourrait causer un choc lectrique 13 N ouvrez jamais l quipement Pour des raisons de s curit seul le personnel de maintenance qual...

Страница 7: ...damage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power b...

Страница 8: ...ec le m me type ou quivalent recom mand par le fabricant Jetez les batteries usag es selon les instructions du fabri cant Warning Warnings indicate conditions which if not observed can cause personal...

Страница 9: ...r Please use the Jacketed power cable with 120 Volt 18AWG or 6Amp To connect between the equipment and the DC power source Turn OFF DC power source and equipment that is to be connected to this produc...

Страница 10: ...ARS P2800 User Manual x...

Страница 11: ...g operation 5 1 6 6 Safety 5 1 6 7 EMC 5 Chapter 2 Hardware Information 7 2 1 ARS P2800 I O Connectors 8 2 2 ARS P2800 External I O Connectors 8 2 2 1 Power Input Connector 8 Figure 2 1 Power Input Co...

Страница 12: ...2 6 Save Exit 35 Appendix A Exploded Setting Diagram 37 A 1 Exploded Diagram 38 Figure A 1 Exploded Diagrams 38 A 2 Setting Diagram 38 Figure A 2 Setting Diagrams 38 Appendix B Watchdog Timer Sample...

Страница 13: ...hapter 1 1 General Information This chapter gives background information on the ARS P2800 Passenger Information System Sections include Introduction General Specifications Power Information Dimensions...

Страница 14: ...n grade working temperature range 25 C to 55 C 1 2 2 Display Display type 28 inch TFT LCD panel Resolution 1920 x 357 Brightness 1000 nits type Contrast Ratio 6500 1 1 2 3 Power Consumption Typical 32...

Страница 15: ...3 ARS P2800 User Manual Chapter 1 General Information 1 3 1 System Block Diagram Figure 1 1 ARS P2800 System Block Diagram...

Страница 16: ...ARS P2800 User Manual 4 1 4 Mechanical Specifications 1 4 1 Dimensions 814 x 178 x 56 Unit mm Figure 1 2 ARS P2800 Mechanical dimension drawing 1 4 2 Weight 8 3 kg...

Страница 17: ...Industrial Grade SSD 25 55 C 13 131 F with air flow Speed 0 7 m sec 1 6 2 Relative Humidity 95 40 C non condensing 1 6 3 Storage Temperature 40 85 C 40 185 F 1 6 4 Vibration during operation When the...

Страница 18: ...ARS P2800 User Manual 6...

Страница 19: ...Chapter 2 2 Hardware Information This chapter introduces external I O and the installation of the ARS P2800 Hardware...

Страница 20: ...ARS P2800 External I O Connectors 2 2 1 Power Input Connector ARS P2800 comes with a M12 A coded connector that carries VDC external power input Figure 2 1 Power Input Connector Table 2 1 Power Input...

Страница 21: ...2 M12 USB connector 2 2 3 M12 X Coded LAN Connector Figure 2 3 M12 X coded connector Table 2 2 USB connector of M12 A Coded Pin Signal Pin Signal 1 Data 2 5V 3 Data 4 GND Table 2 3 LAN Connector of M1...

Страница 22: ...ignments Pin Signal Pin Signal 1 VCC 2 USB data 3 USB data 4 GND Table 2 5 DVI D Connector Pin Signal Pin Signal 1 TMDS Data 2 2 TMDS data 2 3 GND 4 NC 5 NC 6 DDC clock 7 DDC data 8 NC 9 TMDS Data 1 1...

Страница 23: ...Chapter 3 3 BIOS Settings...

Страница 24: ...o modify the basic system configuration This information is then stored in flash ROM to ensure that the setup information is retained even when the system is powered off 3 2 Entering the Setup Menu Po...

Страница 25: ...Above the key legend is an area reserved for text messages When an option is selected in the left frame the color of the text changes to white and is typically accompanied by a text message System Ti...

Страница 26: ...any item such as CPU Configuration in the left frame of the screen to access the submenu for that item Users can view the Advanced BIOS setup options by highlighting various items using the Arrow keys...

Страница 27: ...IOS ACPI auto configuration Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Select the highest ACPI...

Страница 28: ...ARS P2800 User Manual 16 3 2 2 2 Super I O Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 3 2 2 3 H W Monitor...

Страница 29: ...e information about system Temperature Voltage 3 2 2 4 S5 RTC Wake Settings Wake system with Fixed Time Enable or disable System wake on alarm event Selecting FixedTime system will wake on the hr min...

Страница 30: ...sole Redirection Console Redirection This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services EMS Console Redirection This item allows users...

Страница 31: ...ndows XP Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when com bined with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 RedHat Enterp...

Страница 32: ...r Manual 20 3 2 2 7 PPM Configuration CPU C state Report Enable Disable CPU C state report to OS Max CPU C state This option controls Max C states that the processor will support S0ix Enable Disable C...

Страница 33: ...nfiguration Serial ATA SATA Enable Disable Serial ATA SATA Test Mode Test Mode Enable Disable SATA Speed Support SATA Speed Supports Gen1 or Gen2 SATA ODD Port SATA ODD is Port0 or Port1 SATA Mode Sel...

Страница 34: ...ARS P2800 User Manual 22 3 2 2 9 Miscellaneous Configuration OS Selection OS Selection to choose Windows 8 x Windows 7 3 2 2 10 CSM Configuration...

Страница 35: ...STPONED execute the trap during legacy boot Boot option filter This option controls Legacy UEFI ROMs priority Network Controls the execution of UEFI and Legacy PXE OpROM Storage Controls the execution...

Страница 36: ...ass storage device start unit command time out Device power up delay Maximum time the device will take before it properly report itself to the host con troller Auto uses default value for a Root port...

Страница 37: ...er Manual Chapter 3 BIOS Settings Intel R AT Platform PBA Enable Disable BIOS AT code from running 3 2 3 Chipset Configuration North Bridge Details for North Bridge items South Bridge Details for Sout...

Страница 38: ...Manual 26 3 2 3 1 North Bridge Intel IGD Configuration Config Intel IGD settings Graphics Power Management Control Graphics Power Management Control options LCD Control LCD Control Max TOLUD Maximum...

Страница 39: ...boost PAVC Enable Disable protected audio video control DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed graphics memory size used by the Inter nal graphics device DVMT Total Gfx Mem Select DVMT...

Страница 40: ...ARS P2800 User Manual 28 3 2 3 3 Graphics Power Management Control RC6 Render Standby Check to enable render standby support 3 2 3 4 LCD Control...

Страница 41: ...lia HD audio options USB Configuration USB configuration settings PCI Express Configuration PCI Express configuration settings LAN1 Control Enable or Disable the LAN1 LAN1 PXE OpROM Enable or Disable...

Страница 42: ...oller Control Detection of the Azalia device Disabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally Enabled Auto Azalia will be enabled if present disabled otherwise A...

Страница 43: ...f xHCI controller USB2 Link Power Management Enable Disable USB2 Link Power Management USB 2 0 EHCI Support Control the USB EHCI USB 2 0 functions One EHCI controller must always be enabled USB Per Po...

Страница 44: ...00 User Manual 32 3 2 3 8 PCI Express Configuration PCI Express Port 0 Enable or Disable the PCI Express Port 0 in the chipset Hot Plug Enable or disable PCI Express Hot Plug Speed Configure PCIe port...

Страница 45: ...iguration Select the Security tab from the main BIOS Setup Utility menu All security setup options such as password and virus protection can be accessed from this menu To access the submenu of any ite...

Страница 46: ...535 0xFFFF indicates that firm ware will wait for user input before booting This means the default boot selec tion is not automatically started by the firmware Bootup NumLock State Select the keyboard...

Страница 47: ...m allows you to rest system setup without saving any changes Save Changes This item allows you to save changes done so far to any of the options Discard Changes This item allows you to discard changes...

Страница 48: ...ARS P2800 User Manual 36...

Страница 49: ...Appendix A A Exploded Setting Diagram...

Страница 50: ...ARS P2800 User Manual 38 A 1 Exploded Diagram Figure A 1 Exploded Diagrams A 2 Setting Diagram Figure A 2 Setting Diagrams...

Страница 51: ...Appendix B B Watchdog Timer Sample Code...

Страница 52: ...dlib include cstdio include sys io h include unistd h using namespace std const unsigned int baseAddress 0xA00 void setWDT unsigned char int main int argc char argv unsigned char inputData printf Plea...

Страница 53: ...41 ARS P2800 User Manual Appendix B Watchdog Timer Sample Code...

Страница 54: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Отзывы: