Страница 1: ...User Manual AIMB 506 Intel Core i7 i5 i3 Pentium Celeron LGA1151 MicroATX with VGA DVI DP eDP LVDS 14 COM Dual LAN DDR4 PCIe x 16 PCIe x 1 PCI x 2 and SATAIII...

Страница 2: ...ns without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use n...

Страница 3: ...aximum performance from your products So if you run into technical difficulties we are here to help For the most frequently asked questions you can easily find answers in your product documentation Th...

Страница 4: ...oid the compliance to FCC regula tions and therefore the user s authority to operate the equipment CPU Compatibility Caution There is a danger of a new battery exploding if it is incorrectly installed...

Страница 5: ...l the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when th...

Страница 6: ...sales repre sentative immediately We have carefully inspected the AIMB 506 mechanically and electrically before shipment It should be free of marks and scratches and in perfect working order upon rec...

Страница 7: ...Mode Selector 9 Table 1 5 PSON1 ATX AT Mode Selector 9 1 8 5 JWDT1 JOBS1 Watchdog Timer Output OBS Alarm Option 10 Table 1 6 JWDT1 JOBS1 Watchdog Beep Pin Header 10 1 8 6 JSETCOM3 7 COM3 7 RS232 RS42...

Страница 8: ...o Connector FPAUD1 28 2 18 Digital Audio Connector SPDIF1 29 2 19 M 2 B Key 2242 M2B1 29 2 20 SMBUS Header SMBUS1 30 Chapter 3 BIOS Operation 31 3 1 Introduction 32 3 2 BIOS Setup 32 3 2 1 Main Menu 3...

Страница 9: ...ch Pin Header JCASEOP_SW1 104 B 17 Case Open Pin Header JCASE1 105 B 18 Keyboard Mouse Pin Header KBMS1 105 B 19 SYSTEM FAN Header SYSFAN3 105 B 20 SYSTEM FAN Header SYSFAN4 105 B 21 COM Port Pin Head...

Страница 10: ...eader INV1 123 B 54 LVDS Panel Voltage Selection Header JLVDS1 123 B 55 PCIe x1 Slot PCIEX1_1 124 B 56 LVDS eDP Panel Header LVDS_EDP1 125 B 57 LVDS VESA JEIDA Format Selection Pin Header JLVDS_VCON1...

Страница 11: ...Chapter 1 1 General Information...

Страница 12: ...rd with balanced expendability and perfor mance Wide selection of storage devices SATAIII HDD customers benefit from the flexibility of using the most suitable storage device for larger capacity Optim...

Страница 13: ...3 4 Graphics Controller Intel HD Graphics Display memory 1 GB maximum shared memory with 2GB and above system memory installed DVI Supports DVI up to resolution 1920 x 1200 60Hz refresh rate VGA Supp...

Страница 14: ...drives and a keyboard In addition the board has a number of jumpers used to configure your system for your application The tables below list the function of each of the board jumpers and connectors La...

Страница 15: ...al 2 x 10 pin header on board optional AUDIO1 Line out Mic IN connector FPAUDIO1 Front panel audio connector SPI_CN1 SPI flash programming connector SATA1 3 Serial III ATA connector GPIO1 GPIO pin hea...

Страница 16: ...AIMB 506 User Manual 6 1 5 Board Layout Jumper and Connector Locations Figure 1 1 Jumper and Connector Locations Figure 1 2 I O Connectors...

Страница 17: ...arges As a safety precaution use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis Cauti...

Страница 18: ...a jumper you connect the pins with the clip To open or turn OFF a jumper you remove the clip Sometimes a jumper consists of a set of three pins labeled 1 2 and 3 In this case you connect either pins...

Страница 19: ...t 1 1 Table 1 4 JLVDS1 LVDS Panel 3 3 V 5 V 12 V Selector Closed Pins Result JEDP1 4 6 Jumper for 3 3 V EDP1 2 4 Jumper for 5 V JEDP1 3 4 Jumper for 12 V Jumper position for 3 3V Default Jumper positi...

Страница 20: ...m Option Table 1 6 JWDT1 JOBS1 Watchdog Beep Pin Header Pin Pin Name 1 NC 2 Watchdog Reset output 3 System Reset input 4 SIO Warning Beep output 5 SP1 Buzzer Beep input Watchdog Timer Output 2 3 Defau...

Страница 21: ...n Pin Signal Pin Signal 1 UART_SIN 2 2 RXD_RS485 3 UART_SIN 2 4 RXD_RS422 5 UART_SIN 2 6 RXD_RS232 7 DCDB 8 SOUT 2 9 COM2_DCD 10 COM2_SOUT 11 COM2_TXD485 12 COM2_RXD485 13 SIN B 14 DTR B 15 COM2_SIN 1...

Страница 22: ...the DIMM module along the plastic guides on both ends of the socket Then firmly but gently avoid pushing down too hard press the DIMM module well down into the socket until you hear a click when the t...

Страница 23: ...or Intel i5 9500E i5 9500TE 9MB for Intel i5 8500 i5 8500T 6MB for Intel i3 9100E i3 9100TE 6MB for Intel i3 8100 i3 8100T 4MB for Intel Pentium G5400 G5400T 2MB for Intel Celeron G4900 G4900T The bui...

Страница 24: ...AIMB 506 User Manual 14...

Страница 25: ...Chapter 2 2 Connecting Peripherals...

Страница 26: ...bps and Rev 3 0 sup ports transmission rates up to 5 Gbps and is fuse protected The USB interface can be disabled in the system BIOS setup The AIMB 506 is equipped with two high performance 1000 Mbps...

Страница 27: ...Connecting Peripherals 2 3 VGA1 DVI D Connector VGA1 DVI 1 Connector AIMB 506 includes VGA1 and DVI interfaces that can drive conventional VGA1 and DVI displays Pin assignments for COM1 and DVI conne...

Страница 28: ...nect to serial devices such as a mouse or a printer or to a com munications network The IRQ and address ranges for both ports are fixed However if you want to disable the port or change these paramete...

Страница 29: ...AIMB 506 User Manual Chapter 2 Connecting Peripherals 2 5 Display Ports DP1 AIMB 506 has one external DP connector to support the Display Port panel DP max resolution support goes to 4096 x 2304 60 H...

Страница 30: ...oard and Mouse Connector KBMS1 6 pin mini DIN connectors KBMS1 support the PS 2 keyboard and PS 2 mouse by a cable P N 1703060191 2 7 CPU Fan Connector CPU_FAN1 If a fan is used this connector support...

Страница 31: ...21 AIMB 506 User Manual Chapter 2 Connecting Peripherals 2 8 System FAN Connector SYSFAN1 2 3 4 If a fan is used this connector supports cooling fans of 500 mA 6 W or less...

Страница 32: ...PWR_SW for convenient power on and off 2 9 2 Reset JFP1 RESET Many computer cases offer the convenience of a reset button Connect the wire for the reset button 2 9 3 HDD LED JFP1 HDDLED You can conne...

Страница 33: ...ower Mode the system turns on off via the power supply switch The third is another AT Power Mode which makes use of the front panel power switch The power LED status is indicated in the following tabl...

Страница 34: ...AIMB 506 User Manual 24 2 11 Serial ATA Interface SATA1 SATA3 AIMB 506 features a high performance Serial ATA III interface up to 600 MB s which eases hard drive cabling with thin space saving cables...

Страница 35: ...nual Chapter 2 Connecting Peripherals 2 12 8 pin Alarm Board Connector VOLT1 VOLT1 connects to the alarm board on the chassis These alarm boards give warn ings if a power supply or fan fails or if the...

Страница 36: ...ctors in only one direction Determine the proper orientation and push down firmly until the connectors mate completely Note 1 Please connect the ATX12V2 connector with the PSU ATX 12V 4 pin connector...

Страница 37: ...MB 506 User Manual Chapter 2 Connecting Peripherals 2 14 General Purpose I O Connector GPIO1 2 15 eDP LVDS Connector eDP1 LVDS Note LVDS is BOM option with eDP Only G2 and F Sku default with eDP conne...

Страница 38: ...ule that supports either HD Audio or legacy AC 97 optional audio standard Connect this connector with the front panel audio I O module cable Note For motherboards with the optional HD Audio feature we...

Страница 39: ...ector is for the S PDIF audio module to allow digital output sound Connect one end of the S PDIF audio cable to this connector and the other end to the S PDIF module 2 19 M 2 B Key 2242 M2B1 M 2 B key...

Страница 40: ...AIMB 506 User Manual 30 2 20 SMBUS Header SMBUS1 AIMB 506 provides SMBUS connector for customer connection to SMBUS protocol embedded device It can be configured to I2C by customer s request...

Страница 41: ...Chapter 3 3 BIOS Operation...

Страница 42: ...with a SETUP utility that allows users to configure required settings or to activate certain system features The SETUP saves the configuration in the FLASH of the motherboard When the power is turned...

Страница 43: ...ns cannot be configured options in blue can The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highl...

Страница 44: ...ect any of the items in the left frame of the screen such as CPU Configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlighting it using the Arrow keys...

Страница 45: ...35 AIMB 506 User Manual Chapter 3 BIOS Operation 3 2 2 1 CPU Configuration The item shows you CPU specification and feature the content would be different for different CPU...

Страница 46: ...AIMB 506 User Manual 36 3 2 2 2 PCH FW Configuration...

Страница 47: ...37 AIMB 506 User Manual Chapter 3 BIOS Operation Firmware Update Configuration ME FW Image Re Flash Disabled Local FW Update Enabled...

Страница 48: ...S TPM Trusted Platform Mod ule is a secure key generator and key cache management component enables pro tected storage of encryption keys and authentication credentials for enhanced security capabilit...

Страница 49: ...bernation Enabled Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Auto Select ACPI sleep state the system will enter wh...

Страница 50: ...al 40 3 2 2 5 NCT6116D Super I O Configuration Super I O Chip NCT6116D Serial Port 1 Configuration Serial Port Enabled Device Settings I O 3F8h IRQ 4 Change Settings Auto To select an optimal setting...

Страница 51: ...l Chapter 3 BIOS Operation Serial Port 2 Configuration Serial Port Enabled Device Settings I O 2F8h IRQ 3 Change Settings Auto To select an optimal setting for serial port 2 Serial Port 3 Configuratio...

Страница 52: ...h IRQ 7 Change Settings Auto RS486 Auto Flow Disabled To select an optimal setting for serial port 3 Serial Port 4 Configuration Serial Port Enabled Device Settings I O 2E8h IRQ 7 Change Settings Auto...

Страница 53: ...43 AIMB 506 User Manual Chapter 3 BIOS Operation Serial Port 5 Configuration Serial Port Enabled Device Settings I O 280h IRQ 7 Change Settings Auto To select an optimal setting for serial port 5...

Страница 54: ...AIMB 506 User Manual 44 Serial Port 6 Configuration Serial Port Enabled Device Settings I O 288h IRQ 7 Change Settings Auto To select an optimal setting for serial port 6...

Страница 55: ...et the CPU warning temperature threshold When the system reaches the warning temperature the speaker will beep ACPI Shutdown Temperature Disabled Use this to set the ACPI shutdown temperature threshol...

Страница 56: ...de Configuration CPU FAN Mode SMART FAN IV Mode The item shows you CPU temperature and fan speed PWM information SYSFAN Mode SMART FAN IV Mode The item shows you system temperature and fan speed PWM i...

Страница 57: ...6 User Manual Chapter 3 BIOS Operation Digital I O Pin 1 16 Input 3 2 2 7 NCT5114DSEC Super I O Configuration Serial Port 7 Configuration Serial Port Enabled Device Settings I O 240h IRQ 5 Change Sett...

Страница 58: ...User Manual 48 To select an optimal setting for serial port 7 Serial Port 8 Configuration Serial Port Enabled Device Settings I O 248h IRQ 5 Change Settings Auto To select an optimal setting for seria...

Страница 59: ...User Manual Chapter 3 BIOS Operation Serial Port 9 Configuration Serial Port Enabled Device Settings I O 250h IRQ 5 Change Settings Auto To select an optimal setting for serial port 9 Serial Port 10 C...

Страница 60: ...User Manual 50 Serial Port Enabled Device Settings I O 258h IRQ 5 Change Settings Auto To select an optimal setting for serial port 10 3 2 2 8 NCT5114DTRD Super I O Configuration Serial Port 11 Confi...

Страница 61: ...Enabled Device Settings I O 260h IRQ 15 Change Settings Auto To select an optimal setting for serial port 11 Serial Port 12 Configuration Serial Port Enabled Device Settings I O 268h IRQ 15 Change Se...

Страница 62: ...AIMB 506 User Manual 52 Serial Port 13 Configuration Serial Port Enabled Device Settings I O 270h IRQ 15 Change Settings Auto To select an optimal setting for serial port 13...

Страница 63: ...n Serial Port 14 Configuration Serial Port Enabled Device Settings I O 278h IRQ 15 Change Settings Auto To select an optimal setting for serial port 14 3 2 2 9 S5RTC Wake Settings The item allows you...

Страница 64: ...54 Wake system with Fixed Time Disabled 3 2 2 10 Serial Port Console Redirection Console Redirection Disabled Enable or disable the console redirection feature Note When enabled system will wake up o...

Страница 65: ...s support for legacy USB Auto option disables legacy support if no USB devices are connected XHCI Hand off Enabled USB Mass Storage Driver Support Enabled USB hardware delays and time outs USB Device...

Страница 66: ...PCI device UEFI Note If your HDD or other boot device is installed as Legacy mode it may cause blue screen situation There are 2 ways to solve this 1 Re install your OS as UEFI Mode 2 Change all of s...

Страница 67: ...57 AIMB 506 User Manual Chapter 3 BIOS Operation 3 2 2 13 Network Stack Configuration Disabled Enable Disable UEFI Network Stack Note When network stack enable item must enable LANx PXE OpROM enable...

Страница 68: ...n select any item in the left frame of the screen such as PCI express Con figuration to go to the sub menu for that item Users can display a Chipset Setup option by highlighting it using the Arrow key...

Страница 69: ...59 AIMB 506 User Manual Chapter 3 BIOS Operation 3 3 1 System Agent SA Configuration VT d Enabled Disable or enable VT d function on MCH 3 3 1 1 Memory Configuration...

Страница 70: ...ax TOLUD Dynamic Maximum Value of TOLUD Dynamic assignment would adjust TOLUD automat ically based on largest MMIO length of installed graphic controller Retrain on Fast Fall Enabled Enable or disable...

Страница 71: ...Keep IGD enabled based on the setup options GTT size 8MB Aperture Size 256MB DVMT Pre Allocated 32M Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT...

Страница 72: ...are verified Display Combination List BIOS DOS WES 8 Single Display VGA PASS PASS PASS DVI PASS PASS PASS DP PASS PASS PASS EDP LVDS PASS PASS PASS Dual Display VGA DVI NA NA PASS VGA EDP LVDS NA NA...

Страница 73: ...63 AIMB 506 User Manual Chapter 3 BIOS Operation 3 3 1 3 DMI Configuration DMI MAx Link Speed Auto...

Страница 74: ...Enabled PCIe ASPM will be programmed after OpROM Disabled PCIe ASPM will be programmed before OpROM Program Static Phase1 Eq Enabled PEG Gen3 Root Port Preset Value for each Lane Root Port Preset Val...

Страница 75: ...See 3 3 2 2 BIOS Security Configuration Details of BIOS security items See 3 3 2 3 LAN 1controller Enabled Enable or disable the LAN 1 controller LAN 2 controller Enabled PCIE Wake Disabled Enable or...

Страница 76: ...3 3 2 1 PCI Express Configuration PCI Express Clock Gating Enabled Enable or Disable PCI Express clock gating for each port PCIe USB Glitch W A Disabled PCIe USB Glitch W A for bad USB device s connec...

Страница 77: ...0 External IC Enabled Control the PCI Express Root Port ASPM Support Auto Set the ASPM Level Force L0s Force all links to L0s State AUTO BIOS auto configure DISABLE Disables ASPM L1 Substates PCI Exp...

Страница 78: ...Bridge Enabled Control the PCI Express Root Port ASPM Support Auto Set the ASPM Level Force L0s Force all links to L0s State AUTO BIOS auto configure DISABLE Disables ASPM L1 Substates PCI Express L1...

Страница 79: ...press Root Port 1 Enabled Control the PCI Express Root Port ASPM Support Auto Set the ASPM Level Force L0s Force all links to L0s State AUTO BIOS auto configure DISABLE Disables ASPM L1 Substates PCI...

Страница 80: ...AIMB 506 User Manual 70 3 3 2 2 SATA and RST Configuration...

Страница 81: ...gs Administrator Password Select this option and press ENTER to access the sub menu and then type in the password Set the Administrator password User Password Select this option and press ENTER to acc...

Страница 82: ...conds to wait for setup activation key Bootup NumLock State On On or Off power on state for the NumLock Quiet Boot Disabled If this option is set to disabled the BIOS displays normal POST messages If...

Страница 83: ...guration 1 Select Exit Discarding Changes from the Exit menu and press Enter The following message appears Discard Changes and Exit Setup Now Ok Cancel 2 Select Ok to discard changes and exit Discard...

Страница 84: ...BIOS automatically configures all setup items to optimal settings when users select this option Defaults are designed for maximum system perfor mance but may not work best for all computer applicatio...

Страница 85: ...Chapter 4 4 Software Introduction Services...

Страница 86: ...er friendly intelligent and integrated interfaces which speeds up development enhances security and offers add on value for Advantech platforms It plays the role of catalyst between developer and solu...

Страница 87: ...ong and the system does not recover on its own A watch dog timer can be programmed to perform a warm boot restarting the system after a certain number of seconds Hardware Monitor The Hardware Monitor...

Страница 88: ...a file on the customers disk The BIOS Flash utility also provides a command line version and an API for fast implementation into custom ized applications Monitoring Monitoring is a utility for custome...

Страница 89: ...Chapter 5 5 Chipset Software Installation Utility...

Страница 90: ...re familiar with both the relevant software applications and operating sys tem commands Review the relevant operating system commands and the pertinent sections of your application software s user man...

Страница 91: ...81 AIMB 506 User Manual Chapter 5 Chipset Software Installation Utility 5 3 Windows 10 Driver Setup When enter the website of Advantech then search product AIMB 506 There is Chipset driver inside...

Страница 92: ...AIMB 506 User Manual 82...

Страница 93: ...Chapter 6 6 VGA Setup...

Страница 94: ...supported Dual independent displays and enhanced display modes for widescreen flat panels include extended twin and clone dual dis play modes plus optimized 3D support delivers an intensive and realis...

Страница 95: ...Chapter 7 7 LAN Configuration...

Страница 96: ...d RISC core with 24 KB cache On chip voltage regulation Wake on LAN WOL support PCI Express X1 host interface 7 3 Installation The AIMB 506 s Realtek 8111G Gigabit integrated controllers support all m...

Страница 97: ...87 AIMB 506 User Manual Chapter 7 LAN Configuration 7 4 Windows 10 Driver Setup Realtek 8111G Enter the Advantech website then search product AIMB 506 There is LAN driver inside...

Страница 98: ...AIMB 506 User Manual 88...

Страница 99: ...Appendix A A Programming the Watchdog Timer...

Страница 100: ...oton NCT6116D It pro vides the following user programmable functions Can be enabled and disabled by user program Timer can be set from 1 to 255 seconds or 1 to 255 minutes Generates an interrupt or re...

Страница 101: ...MB 506 User Manual Appendix A Programming the Watchdog Timer Unlock Select register of watchdog timer Enable the function of the watchdog timer Use the function of Lock NCT6116D the watchdog timer NCT...

Страница 102: ...F6 hex write 0 stop timer default 01 FF hex The amount of the count in seconds or minutes depends on the value set in register F5 hex This number decides how long the watch dog timer waits for strobe...

Страница 103: ...h Out dx al Dec dx Enable the function of watchdog timer Mov al 30h Out dx al Inc dx Mov al 01h Out dx al Dec dx Set second as counting unit Mov al 0f5h Out dx al Inc dx In al dx And al not 08h Out dx...

Страница 104: ...ute as counting unit Mov al 0f5h Out dx al Inc dx In al dx Or al 08h Out dx al Dec dx Set timeout interval as 5 minutes and start counting Mov al 0f6h Out dx al Inc dx Mov al 5 Out dx al Dec dx Lock N...

Страница 105: ...Out dx al Dec dx Lock NCT6779D Mov al 0aah Out dx al 4 Enable watchdog timer to be reset by keyboard Mov dx 2eh Unlock NCT6779D Mov al 87h Out dx al Out dx al Mov al 07h Select registers of watchdog...

Страница 106: ...dx al Out dx al Mov al 07h Select registers of watchdog timer Out dx al Inc dx Mov al 08h Out dx al Dec dx Enable the function of watchdog timer Mov al 30h Out dx al Inc dx Mov al 01h Out dx al Dec dx...

Страница 107: ...Appendix B B Pin Assignments...

Страница 108: ...al R1 LAN2_VCT R8 LAN2_MDI3 R2 LAN2_MDI0 R9 LAN2_MDI3 R3 LAN1_MDI0 R10 GND R4 LAN2_MDI1 L1 LAN2_ACT R5 LAN2_MDI1 L2 V3 3_LAN2 R6 LAN2_MDI2 L3 LAN2_LED1_1G R7 LAN2_MDI2 L4 LAN2_LED2_100M Pin Signal Pin...

Страница 109: ..._MDI3 R2 LAN1_MDI0 R9 LAN1_MDI3 R3 LAN1_MDI0 R10 GND R4 LAN1_MDI1 L1 LAN1_ACT R5 LAN1_MDI1 L2 V3 3_LAN1 R6 LAN1_MDI2 L3 LAN1_LED1_1G R7 LAN1_MDI2 L4 LAN1_LED2_100M Pin Signal Pin Signal U1 USBV1 U10 U...

Страница 110: ...Signal Pin Signal 11 USBV5 31 USBV6 12 USBPCIE_z_P1 32 USBPCIE_z_P3 13 USBPCIE_z_P1 33 USBPCIE_z_P3 14 GND 34 GND 15 USB3D1_z_RX 35 USB3D3_z_RX 16 USB3D1_z_RX 36 USB3D3_z_RX 17 GND 37 GND 18 USB3D1_z...

Страница 111: ...P1_0 13 DP1_AUX_EN 4 DP1_1 14 GND 5 GND 15 DP1_AUX 6 DP1_1 16 GND 7 DP1_2 17 DP1_AUX 8 GND 18 DP1_HPD 9 DP1_2 19 GND 10 DP1_3 20 V3 3_DP1 Pin Signal Pin Signal 1 DVI1_D0 13 GND 2 DVI1_D0 14 VCC_TMDS 3...

Страница 112: ...gnal Pin Signal D1 VGA1_b_R D9 VCC_TMDS D2 VGA1_b_G D10 GND D3 VGA1_b_B D11 NC D4 CLKREQ D12 VGA1_a_DDAT D5 GND D13 VGA1_b_HS D6 VGA1_FOC_ON D14 VGA1_b_VS D7 GND D15 VGA1_a_DCLK D8 GND Pin Signal Pin...

Страница 113: ...endix B Pin Assignments B 9 CPU Socket LGA 1151 H4 CPU1 B 10 SMBUS Header JSMB2 B 11 CPU FAN Header CPUFAN1 Pin Signal Pin Signal 1 CPU_SDA 3 CPU_SCL 2 GND Pin Signal Pin Signal 1 GND 3 CPU FAN SPEED...

Страница 114: ...DARD B 15 DDR4 DIMM Socket DIMMB1 Please see JEDEC STANDARD B 16 Case Open Switch Pin Header JCASEOP_SW1 Pin Signal Pin Signal 1 GND 3 SYSTEM FAN SPEED 2 SYSTEM FAN VCC 4 SYSTEM FAN PWM Pin Signal Pin...

Страница 115: ...TEM FAN Header SYSFAN3 B 20 SYSTEM FAN Header SYSFAN4 Pin Signal Pin Signal 1 Case Open 2 GND Pin Signal Pin Signal 1 KB_CLK 4 GND 2 KB_DAT 5 V5_DUAL 3 MS_CLK 6 MS_DAT Pin Signal Pin Signal 1 GND 3 SY...

Страница 116: ...COM1_DSR 12 COM2_DSR 3 COM1_SIN 13 COM2_SIN 4 COM1_RTS 14 COM2_RTS 5 COM1_SOUT 15 COM2_SOUT 6 COM1_CTS 16 COM2_CTS 7 COM1_DTR 17 COM2_DTR 8 COM1_RI_V 18 COM2_RI_V 9 GND 19 GND 10 GND 20 GND Pin Signa...

Страница 117: ...OM_SOUT 2 RXDRS485 11 COM_TXD485 3 UART_SIN 12 COM_RXD485 4 RXDRS422 13 SIN 5 UART_SIN 14 DTR 6 RXDRS232 15 COM_SIN 7 DCD 16 COM_DTR 8 SOUT 17 COM_TXD485 9 DCD 18 COM_RXD485 Pin Signal Pin Signal 1 GP...

Страница 118: ...3 5 TXD 3 6 CTS 3 7 DTR 3 8 RI 3 9 GND 10 GND 11 DCD 4 12 DSR 4 13 RXD 4 14 RST 4 15 TXD 4 16 CTS 4 17 DTR 4 18 RI 4 19 GND 20 GND 21 DCD 5 22 DSR 5 23 RXD 5 24 RST 5 25 TXD 5 26 CTS 5 27 DTR 5 28 RI...

Страница 119: ...VOLT1 B 29 ATX Power Header EATXPWR1 Pin Signal Pin Signal 1 AT 3 ATX 2 3 3V Pin Signal Pin Signal 1 5VSB 5 5V 2 GND 6 3 3V 3 GND 7 12V 4 5V 8 12V Pin Signal Pin Signal 1 3 3V 13 3 3V 2 3 3V 14 12V 3...

Страница 120: ...11 9 GND 10 GND 11 DCD 12 12 DSR 12 13 RXD 12 14 RST 12 15 TXD 12 16 CTS 12 17 DTR 12 18 RI 12 19 GND 20 GND 21 DCD 13 22 DSR 13 23 RXD 13 24 RST 13 25 TXD 13 26 CTS 13 27 DTR 13 28 RI 13 29 GND 30 G...

Страница 121: ...nnector KEY 19 Connector KEY 20 NC 21 CONFIG_0 22 NC 23 PCIE_WAKE 24 NC 25 DPR 26 M 2_GNSS_DISABLE 27 GND 28 NC 29 NC 30 UIM RESET I 31 NC 32 UIM CLK I 33 GND 34 UIM DATA I O 35 NC 36 UIM PWR I 37 NC...

Страница 122: ...B 35 USB2 0 Pin Header USB1920 Pin Signal Pin Signal 1 GND 5 RX 2 TX 6 RX 3 TX 7 GND 4 GND Pin Signal Pin Signal 1 GND 5 RX 2 TX 6 RX 3 TX 7 GND 4 GND Pin Signal Pin Signal 1 VBUS 2 VBUS 3 USBPCIE_z_P...

Страница 123: ...1 VBUS 2 VBUS 3 USBPCIE_z_P1_b 4 USBPCIE_z_P2_b 5 USBPCIE_z_P1_b 6 USBPCIE_z_P2_b 7 GND 8 GND 9 NC 10 NC Pin Signal Pin Signal 1 5V 2 HDD LED 3 Power Button 4 SPK_P2 5 HDD LED 6 Power Button 7 SPK_P3...

Страница 124: ...4 B 39 Speaker SP1 B 40 PLED Pin Header JFP2 B 41 SPI Programming Pin Header SPI_CN1 Pin Signal 1 LED Power 2 NC 3 SIO_SUSLED 4 Keyboard Lock 5 GND Pin Signal Pin Signal 1 V3 3_SPI 2 GND 3 CS 4 SCLK 5...

Страница 125: ...TA Connector SATA3 B 43 SPI ROM Socket SPI1 B 44 Clear CMOS Pin Header JCMOS1 Pin Signal Pin Signal 1 GND 5 RX 2 TX 6 RX 3 TX 7 GND 4 GND Pin Signal Pin Signal 1 CS 5 MOSI 2 MISO 6 SCLK 3 WP IO2 7 HOL...

Страница 126: ...SB2 0 Pin Header USB1314 Pin Signal 1 5VSB 2 SMB CLK 3 SMB DAT 4 GND Pin Signal Pin Signal 1 VBUS 2 VBUS 3 USB_HCM_N3 4 USB_HCM_N4 5 USB_HCM_P3 6 USB_HCM_P4 7 GND 8 GND 9 NC 10 NC Pin Signal Pin Signa...

Страница 127: ...3 RXD 7 4 RST 7 5 TXD 7 6 CTS 7 7 DTR 7 8 RI 7 9 GND 10 GND 11 DCD 8 12 DSR 8 13 RXD 8 14 RST 8 15 TXD 8 16 CTS 8 17 DTR 8 18 RI 8 19 GND 20 GND 21 DCD 9 22 DSR 9 23 RXD 9 24 RST 9 25 TXD 9 26 CTS 9...

Страница 128: ...13 GND A13 REFCLK B14 TX0 A14 REFCLK B15 TX0 A15 GND B16 GND A16 RX0 B17 Advantech define A17 RX0 B18 Advantech define A18 GND B19 TX1 A19 Reserved B20 TX1 A20 GND B21 GND A21 RX1 B22 GND A22 RX1 B23...

Страница 129: ...GND A3 TMS B4 NC A4 TDI B5 5V A5 V5 B6 5V A6 INT A B7 INT B A7 INT C B8 INT D A8 V5 B9 CLK33M_PCI2 A9 GNT 1 B10 PCI_REQ 1 A10 V5 B11 CLK33M_PCI3 A11 GNT 2 B12 GND A12 GND B13 GND A13 GND B14 PCI_REQ...

Страница 130: ...GND A38 STOP B39 LOCK A39 V3 3 B40 PERR A40 SMBCLK B41 V3 3 A41 SMBDATA B42 SERR A42 GND B43 V3 3 A43 PAR B44 CBE 1 A44 AD15 B45 AD14 A45 V3 3 B46 GND A46 AD13 B47 AD12 A47 AD11 B48 AD10 A48 GND B49...

Страница 131: ...D A13 GND B14 NC A14 V3 3_DUAL B15 GND A15 RST B16 CLK33M_PCI A16 V5 B17 GND A17 GNT 3 B18 PCI_REQ 3 A18 GND B19 V5 A19 PME B20 AD31 A20 AD30 B21 AD29 A21 V3 3 B22 GND A22 AD28 B23 AD27 A23 AD26 B24 A...

Страница 132: ...8 GND B49 GND A49 AD9 B52 AD8 A52 CBE 0 B53 AD7 A53 V3 3 B54 V3 3 A54 AD6 B55 AD5 A55 AD4 B56 AD3 A56 GND B57 GND A57 AD2 B58 AD1 A58 AD0 B59 V5 A59 V5 B60 ACK64 A60 PCI1_REQ64 B61 V5 A61 V5 B62 V5 A6...

Страница 133: ...x B Pin Assignments B 53 LVDS eDP Backlight Inverter Power Header INV1 B 54 LVDS Panel Voltage Selection Header JLVDS1 Pin Signal 1 12V Inv12 GND 3 BKL EN 4 BKL CTRL 5 5V Pin Signal Pin Signal 1 NC 2...

Страница 134: ...2V B3 12V A3 12V B4 GND A4 GND B5 SMB_CLK A5 Reserved B6 SMB_DATA A6 Reserved B7 GND A7 Reserved B8 3 3V A8 Reserved B9 Reserved A9 3 3V B10 3 3VAUX A10 3 3V B11 WAKE A11 PWRGD B12 Reserved A12 GND B1...

Страница 135: ...N EDP_CPU_TXN2 27 CLK1P EDP_CPU_TXP3 8 A4N 28 CLK2P 9 A0P EDP_CPU_TXP2 29 GND 10 A4P 30 GND 11 GND 31 SCD 12 GND 32 SDD 13 A1N EDP_CPU_TXN1 33 GND 14 A5N 34 GND EDP_CH7511_HPD 15 A1P EDP_CPU_TXP1 35 A...

Страница 136: ...F Pin Header SPDIF1 11 GND 31 SCD EDP_AUX 12 GND 32 SDD EDP_AUX 13 A1N EDP_CPU_TXN1 33 GND 14 A5N 34 GND EDP_CH7511_HPD 15 A1P EDP_CPU_TXP1 35 NC 16 A5P 36 NC 17 GND 37 NC 18 GND 38 NC 19 A2N EDP_CPU_...

Страница 137: ...nt Audio Pin Header FPAUD1 B 61 LAN Active LED Pin Header LANLED1 Pin Signal 1 R 2 GND 3 GND 4 L Pin Signal Pin Signal 1 MIC IN L 2 GND 3 MIC IN R 4 FPAUD_DETECT 5 LINE OUT R 6 SENSE R1 7 SENSE 8 KEY...

Страница 138: ...der JSETCOM1_V1 B 63 COM2 RI Selection Pin Header JSETCOM2_V2 Pin Signal Pin Signal 1 RI 1 2 Advantech define 3 Advantech define 4 5V 5 12V 6 Advantech define Pin Signal Pin Signal 1 RI 2 2 Advantech...

Страница 139: ...129 AIMB 506 User Manual Appendix B Pin Assignments...

Страница 140: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...