SSPBMg-C400-BRE
3.3.2 E
LECTRICAL
C
ONNECTIONS
E Electrical connections to the SSPB consist of the prime power AC LINE applied to the AC
Line Connector (J5). For the connector location, see
Figure 4:
Connectors at page 16.
Perform the electrical connections as follows:
•
Using the connector provided in the shipping kit (item 5,
TABLE 9
at page 36), construct
an
AC Supply cable with a pin assignment as shown in
TABLE 6
at page 17.
•
Verify that the AC power source is turned OFF.
•
Connect the SSPB to the AC power source. For the correct input voltage level refer to
TABLE 3
at page 15.
•
Turn the AC power source ON.
3.3.3 RF C
ONNECTIONS
The following three RF connections are provided by the SSPB:
•
RF input (J1) – N-Type Female, see
Figure 4:
Connectors at page 16. The user needs a
N-Type male connector for the interface connection.
CAUTION!
Beware of the destructive pin depth of the mating connector. When installing an
RF mating connector with a destructive pin depth into an RF component connector, damage may
occur to the RF component connector. A destructive pin depth is a connector having a pin length
that is too long in respect to the reference plane of the connector. The centre pins of the
connectors used by Advantech Wireless have a precision tolerance measured in mils (1/1000
inch). The mating connectors of the various suppliers may not be of precision types.
Consequently, the centre pins of these devices may not have the proper depth.
•
RF output (J7) - CPR-137 waveguide flange (grooved), see
Figure 4:
Connectors at page 16.
The user needs a CPR-137 flat waveguide flange.
•
Attach the correct RF cable with mating connector to their corresponding connector ports on
the SSPB.
•
If necessary, connect a power meter or a spectrum analyzer to the RF output monitor port
(RF MON)
•
Wrap mastic tape (item 8 of
TABLE 9
at page 36) around all of the SSPB connectors in
order to prevent water/humidity ingress, which may result in damage.
•
Squeeze the tape tightly, ensuring that both ends of the tape have formed around the
connector and the cable.
Page
19
Содержание SSPBMg-C400-BRE
Страница 12: ...SSPBMg C400 BRE Figure 1 Product Outline Page 11 ...
Страница 13: ...SSPBMg C400 BRE Figure 2 Product Outline fans side view Page 12 ...
Страница 17: ...SSPBMg C400 BRE Figure 4 Connectors Page 16 ...
Страница 29: ...SSPBMg C400 BRE Figure 7 HyperTerminal RS 232 Communication help command and response Page 28 ...
Страница 30: ...SSPBMg C400 BRE Figure 8 HyperTerminal RS 232 Communication status command and response Page 29 ...