Installation Guideline 

The installation must be in compliance with the National Electrical Code, your local electrical and plumbing 

codes.

 

1.  Make sure the appliance is intact, and the fittings are complete. 

2.  Please make sure the main power supply, water pressure, grounding condition, amp meter and wire reach the 

standard of installation requirement.       

3.  The  appliance  must  be  connected  to  properly  grounded  dedicated  branch  circuits  of  proper  voltage  rating. 

Ground must be brought to the 

“ground” at the circuit breaker panel.   

4.  This appliance 

MUST

 be permanently connected to the fixed circuit breaker. If you don

’t use the heater, please 

switch off the circuit breaker.   

5. 

DO  NOT 

install  this  appliance  near  flammable  materials  or  a  strong  magnetic  field.  The  unit  must  only  be 

mounted  in  a  VERTICAL  position  near  by  the  water  fittings.  When  installing  new  unit  please  connect  water 

fittings and turn water on so water flows through unit before turning POWER ON. 

 

Installation Location & Method

 

 

Fixed installation on the wall 

Locate an appropriate place on a section of wall as above mentioned. 

 

 

 

 

E    L1   L2   L1   L2   L1   L2

bottom case

control board

Display screen

Terminal blocks

flowmeter

Temp.sensor

heating chamber

Display screen

UP

ON/OFF

DOWN

260mm

285m

m

Содержание ADV120FDCH

Страница 1: ...is appliance CONTENTS Important Safety Instructions page 2 Electrical Diagram page 3 Technical Data and Product Structure page 4 Installation Guideline page 6 Operation Instructions page 10 Trouble shooting page 11 Normal Maintenance page 12 CANADA USA UV Corp NPV group LLC Markham Ontario Akron Ohio 1 866 833 2247 1 800 561 6838 ...

Страница 2: ... a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 6 This appliance MUST be permanently connected to the fixed circuit breaker and it must be installed vertically DO NOT install this appliance near to flammable materials or strong magnetic fields 7 This appliance is forbidden to be switch on if you think it may be frozen as this ...

Страница 3: ...e electricity will be cut off to avoid getting scalded and the screen displays E1 The appliance will start to work automatically when the temp drops to the set temperature 4 Malfunction of sensor when there is malfunction with the temperature sensor the heater stops working and displays E3 5 Conversion between degree Fahrenheit and degree Celsius Electrical Diagram MODEL ADV120FDCH ADV150FDCH ADV1...

Страница 4: ...equired circuit breaker A 60 2 X 40 2x50 3 X 40 3 X 40 3 X 50 Min wire size AWG cooper 8 2 X 8 2 X 8 3 X 8 3 X 8 3 X 8 Min water flow to activate GPM L min 0 85 3 2 0 85 3 2 0 85 3 2 0 85 3 2 0 85 3 2 0 85 3 2 Weight kg 3 6 5 3 5 3 5 5 5 5 5 5 Product Dimensions mm 385x260x93 385x260x93 385x260x93 385x260x93 385x260x93 385x260x93 Water connections NPT 1 2 3 4 3 4 3 4 3 4 3 4 L1 L1 L1 T1 T2 T3 R1 R...

Страница 5: ...CH ADV150FDCH ADV180FDCH 260mm 285mm E L1 L2 Display screen Display screen UP ON OFF DOWN E L1 L2 L1 L2 bottom case control board Display screen Terminal blocks flowmeter Temp sensor heating chamber Display screen UP ON OFF DOWN 260mm 285mm ...

Страница 6: ...uit breaker panel 4 This appliance MUST be permanently connected to the fixed circuit breaker If you don t use the heater please switch off the circuit breaker 5 DO NOT install this appliance near flammable materials or a strong magnetic field The unit must only be mounted in a VERTICAL position near by the water fittings When installing new unit please connect water fittings and turn water on so ...

Страница 7: ...n back of the appliance Fig 3 Remove the bracket from the appliance Fig 4 Hold the back bracket hanger in position against the wall and mark the three mounting holes Drill three holes of 6 00mm diameter the distance between every two holes is 100mm Put plastic anchor in the hole fix ...

Страница 8: ...d secure the hanger using the screws supplied or an appropriate alternative method Fig 5 Undo screws on appliance to remove the front cover Carefully use hands to pull out the screen row line plug before removing the front cover ...

Страница 9: ...please notice the guidance logo below the terminal blocks ADV120FDCH will be connected to one circuit breaker ADV150FDCH ADV180FDCH will be connected to two circuit breakers ADV210FDCH ADV240FDCH ADV270FDCH will be connected to three circuit breakers Fig 8 Please plug in the screen row line plug then affix the front cover on appliance screw in place E L1 L2 L1 L2 L1 L2 E L1 L2 L1 L2 L1 L2 ...

Страница 10: ...el switch is OFF to avoid any danger of electric shock all mounting and plumbing must be completed before proceeding with electrical hook up 4 ADV120FDCH can be connected to a single circuit use a supply cable protected by a double pole breaker 5 ADV150FDCH ADV180FDCH require two independent circuits Use two supply cables protected by two separate double pole breakers 6 ADV210FDCH ADV240FDCH ADV27...

Страница 11: ...ble shooting 7 and 8 should only be performed by qualified electrician The person who initially installed the unit is the best one to contact for help Problems Possible Causes Corrective Actions 1 Inlet and outlet fittings leaking A Fittings are not tight B Rubber washer worn out A Tighten fittings B Change rubber washer 2 LED no signal A Power not connected B LED damaged A Connect power to the un...

Страница 12: ...iple circuit breakers Turn OFF ALL WATER SUPPLY and ALL POWER SUPPLY This unit does not require any regular maintenance However to ensure consistent water flow it is recommended to follow the following procedures 1 Periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head 2 There is a built in filter screen at inlet connection which should be cleaned f...