ADV210FDCH ADV240FDCH ADV270FDCH
■
Installation Guideline
The installation must be in compliance with the National Electrical Code, your local electrical and plumbing
codes.
1. Make sure the appliance is intact, and the fittings are complete.
2. Please make sure the main power supply, water pressure, grounding condition, amp meter and wire reach the
standard of installation requirement.
3. The appliance must be connected to properly grounded dedicated branch circuits of proper voltage rating.
Ground must be brought to the
“ground” at the circuit breaker panel.
4. This appliance
MUST
be permanently connected to the fixed circuit breaker. If you don
’t use the heater, please
switch off the circuit breaker.
5.
DO NOT
install this appliance near flammable materials or a strong magnetic field. The unit must only be
mounted in a VERTICAL position near by the water fittings. When installing new unit please connect water
fittings and turn water on so water flows through unit before turning POWER ON.
■
Installation Location & Method
●
Fixed installation on the wall
Locate an appropriate place on a section of wall as above mentioned.
E L1 L2 L1 L2 L1 L2
bottom case
control board
Display screen
Terminal blocks
flowmeter
Temp.sensor
heating chamber
Display screen
UP
ON/OFF
DOWN
260mm
285m
m