Advantage Controls MINI-TROL IF Скачать руководство пользователя страница 1

1

Manual

MINI-TROL IF

Reverse Osmosis 

Controller

Installation

Maintenance

Repair

Manual

Advantage Controls

4700 Harold-Abitz Dr.

Muskogee, OK  74403

Phone: 800-743-7431

Fax: 888-686-6212

www.advantagecontrols.com

email: [email protected]

03/2021

Содержание MINI-TROL IF

Страница 1: ...erse Osmosis Controller Installation Maintenance Repair Manual Advantage Controls 4700 Harold Abitz Dr Muskogee OK 74403 Phone 800 743 7431 Fax 888 686 6212 www advantagecontrols com email support advantagecontrols com 03 2021 ...

Страница 2: ...to the controller is required proceed as follows A Remove the enclosure cover B Mark and drill necessary electrical entry holes in the empty enclosure C Terminate necessary wiring to the terminal strips as required See Fig 1 Each terminal is labeled for the proper connection Terminal strip P1 is high voltage for power motor inlet and flush solenoid Utilize proper 3 conductor wire for the appliance...

Страница 3: ... SWITCHES J8 TANK FULL FLUSH 24 HOUR FLUSH WARNING All switch inputs must be dry contact only If voltage is applied to these inputs damage to the controller will result For power with neutral and hot leads L1 is hot and L2 is neutral SELECTABLE JUMPERS J7 K3 INLET RELAY FLUSH RELAY K3 RO PUMP RELAY CAUTION REPLACE FUSES WITH SAME TYPE OR EQUIVALENT K4 J6 J5 J4 B B A A ...

Страница 4: ...me If jumper J 8 is in Position B the RO unit will flush on tank full During Flush the inlet and flush valves are open and the RO pump is On The flush time is 5 minutes The status LED will double flash AMBER CAUTION 1 There are live circuits inside the controller even when the power switch on the front panel is in the OFF position Never open the front panel without first disconnecting power from t...

Страница 5: ...her expressed or implied No agent of ours is authorized to provide any warranty other than the above 30 Day Billing Memo Policy Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service with minimum downtime If your unit malfunctions call 1 800 743 7431 and provide our technician with Model and Serial Number information If we are unable to diagnose and solve yo...

Страница 6: ...6 Notes ...

Страница 7: ...ollers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Filter Equipment Glycol Feed Systems Pre Fabricated Systems Get the Advantage 5 4 3 2 1 0 9 8 7 6 BACK HOME HELP ENTER CANCEL SET UP RUN 5 4 3 2 1 ENTER HELP 5 4 3 CHANGE RUN SET UP 0 9 8 2 1 7 6 HOME BACK ...

Страница 8: ...8 ...

Отзывы: