Stage 4.
THE UO-PHASE. The constant voltage charging, Float LED is ON.
In this stage, The charging voltage at this mode will be 4% less than the Float voltage only for maintaining the capacity.
Remark: If the battery does not reaches the charging voltage in 12 hours, the charger will automatically goes to Float mode. This
is call safety timer.
E. User Define battery setting
There are two user define can be preset by end user, Battery Selection Switch (4) set to position 7 or 8.
Connect the charger to personal computer through USB port (6) then you can set your own charging configuration.
Remark: Optional remote display cannot configure the user define battery.
F. Equalization Charging for wet type battery only
Wet lead acid battery requires periodic high voltage charging (about 10% overcharge absorption voltage) to balance the voltage
of each cell, reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates. You can
use the Equalization Selection Switch (8) to perform the manual equalization through optional remote display or Auto
equalization by charger itself.
Once Auto it is selected, the charger will start Equalization automatically if charger keeps at Float mode for over 21 days.
After entered into this mode, the Absorption indicator will flash. This will put the charger keep Equalization for 240 minutes.
The charger will go to Float once completed.
Remark : 1. This mode only can be operated at Flooded battery selected (Battery Selection Switch (4) set to positions 1, 9 or 0)
2. During this mode, operator can press the FUNC button (optional remote display) for 5 seconds to force the
charger to Float mode anytime.
3. Take special precautions as battery will emit explosive gas during equalization charge.
G. Dual bank charging
This feature is for caravans, and vehicles with two separate batteries.
The two batteries must be of same chemical make up and type to avoid over and under charging because only one setting of
charging profile for both.
Two batteries are charged simultaneously and the battery with the lowest level gets most share of the current in the Bulk charge
stage until it is up to the same voltage level of the second battery (battery with higher initial level).
Both batteries will go to the Absorption and the Float Charge at the same time.
H. Power Level adjustment
End user can set the maximum output current so to make the charger can suitable for different capacity battery
Make sure the charger is power OFF before adjust the power level.
Use a small slot type screw driver to select the maximum output current through the Charging Current Selection Switch (5).
1. Position 0: 100% of the rated current
2. Position 9: 90% of the rated current
3. Position 8: 80% of the rated current
4. Position 7: 70% of the rated current
5. Position 6: 60% of the rated current
6. Position 5: 50% of the rated current
7. Position 4: 40% of the rated current
8. Position 3: 30% of the rated current
9. Position 2: 20% of the rated current
0. Position 1: 10% of the rated current
I.
Temperature Sensor
Warning :
The temperature sensor must be installed at the Negative Terminal of the battery terminal, wrong connection to the Positive
Terminal will damage the charger and the sensor .
The temperature sensor (accessory) is used to optimal charging over wide ambient temperature range.
Fix the temperature sensor in a position on the battery which is not affected by other cooling or heating source.
Plug in the temperature sensor before switch on the charger to activate the temperature control function, never plug in the charger
during charging.
Compensation voltage for this temperature sensor is 20mV/C, the higher the battery temperature, the lower the charging voltage.
When battery temperature reaches 60°C, the charger will shutdown, Fault and OTP indicator will light up.