Bat temperature above : Charger will shut down output when temperature detected by remote sensor is
about the set value.
Battery voltage above : Charger will shut down output if battery voltage is over this set voltage.
Charging time longer than : Charger shuts down output if the total charging time in bulk and absorption
stages is longer than this set limit in hour
。
3.7.4 Profile- Charge Stage setting
There are 1 to 7 charging stage that can be used , each has its own charging
voltage and current limit.
3.7.5 Profile- Charge Stage change to next stage condition :
These are the available threshold parameters that cause shift of charging stage to the next one, it is not
necessary to use all the parameters. The inter-action among the parameters is controlled by the following
logic :
None means skip this condition
And means must get to this condition to move to the next stage
Or means any one the selected conditions will move to the next stage
Note: It is not permissible to have “And “ with “Or” in the stage
Always press “OK” key to store set conditions.