a)

 

If the configuration is successful “connection OK “ will appear .

b)  If configuration fails , “No Connection “ will appear.

               

3.6 Trouble shooting for No Connection 

Содержание HBC-3130

Страница 1: ...charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face away w...

Страница 2: ...er programmable charging profiles for the professional users through USB port by personal computer In addition the programmed maintenance charge provides a timely Equalization charge for the Wet lead...

Страница 3: ...h fuse holder 12 Temperature Sensor Socket Connection to optional accessory temperature sensor Sensor to increase decrease charging voltage at low high battery temperature B Battery Type Selection Mak...

Страница 4: ...ion and then the battery connection Please notice the tightness of the power cables from the power supply to the load If the cables are not fastened well enough the total resistance of the connecting...

Страница 5: ...avans and vehicles with two separate batteries The two batteries must be of same chemical make up and type to avoid over and under charging because only one setting of charging profile for both Two ba...

Страница 6: ...um one way distance feet for 2 Voltage loss 40A Maximum one way distance feet for 2 Voltage loss 60A 10 5 26 3 8 2 8 1 6 8 8 37 6 4 5 2 5 6 13 3 9 5 7 2 3 6 4 21 2 15 11 2 6 8 2 33 6 24 18 11 1 0 53 5...

Страница 7: ...witch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable size ca...

Страница 8: ...rotection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Re...

Страница 9: ...coupler HBR 3100 accessories II Connection 1 10 Meters Phone Cable 2 In Line Coupler 6P6C 3 HBR 3100 Remote Display Module III Control and Indicator 1 Output ON OFF To switch the charger output ON and...

Страница 10: ...Time Display units total run time 9 Output Power Level Display current output level 10 Software Version Displays the current control software version Remote Short cut 1 Press and hold the SET button...

Страница 11: ...g Systems This software is compatible with 32 bit computer and operating systems of Win Vista XP and Win 7 Installing the USB Driver 1 1 CD USB Drivers for Win_2K_XP_S2K3_Vista CP210xVCPInstaller exe...

Страница 12: ...USB Driver has been successfully installed 2 Installing the HBC Charge Program 2 1 Double click on CD setup exe 2 2 Follow the steps as shown in the following windows it may take a few minutes to inst...

Страница 13: ......

Страница 14: ...2 Select a COM Port number that matches the USB com port number 3 3 You can find your USB Com number from your device manager as shown in window at section1 4 In this example is Com 3 for the USB Com...

Страница 15: ...a If the configuration is successful connection OK will appear b If configuration fails No Connection will appear 3 6 Trouble shooting for No Connection...

Страница 16: ...o download accumulative run time of the charger since the first operation the Output charging voltage and current values at 10 minute intervals the voltage at each of the two battery terminals are als...

Страница 17: ...7 2 Profile General setting Nominal bat Voltage select 12V or 24 V battery Nominal bat Capacity Key in the battery bank AH Click OK to confirm save settings 3 7 3 Profile Protection conditions settin...

Страница 18: ...ng stage that can be used each has its own charging voltage and current limit 3 7 5 Profile Charge Stage change to next stage condition These are the available threshold parameters that cause shift of...

Страница 19: ...3 7 6 Profile Conditions for Jumping from one Stage to any other Stage Non sequential change of stage selection and condition windows...

Страница 20: ...minute interval When the data bank is full new data will push the oldest out Each set of data is marked with a number new set of data has the highest number 3 8 1 Get Data Total Run Time This drop wi...

Страница 21: ...all the data from record 1 which is the oldest one to the most recent one Chr volt charging voltage Curr charging current bat 1 volt voltage at battery terminal 1 bat 2 volt voltage at battery termina...

Страница 22: ...ing the Data Log Graph When you open the data log you saved by this software the following graph will appear Voltage Blue color Current red color WH Watt hour with 30 deducted adjustment for energy ch...