7
The Advanced® Model BR2 Service Manual
Model BR2 Specifications
Electrical:
Voltage:
100 to 120 VAC (1/4 A) or 200 to 240
VAC 1/8 A)
Frequency:
50 or 60 Hz
Fuses:
1/4-Amp time delay for 100-120 VAC;
1/8-Amp time delay for 200-240 VAC
Power:
15 Watts
STAT Mode:
Power left on continuously
Test Capability:
Total and Direct Bilirubin, both on
the same serum orplasma sample
Sample Volume:
30
µ
L
Sample Capacity:
Single sample, disposable cuvettes
Readout:
Three-digit, seven-segment LED display
Units:
mg/dL or
µ
mol/L (S.I. units for export
only; 1 mg/dL bilirubin = 17.1
µ
mol/L)
Range:
0 to 30 mg/dL
Resolution:
±0.1 mg/dL
Performance at Reference Conditions1
Linearity:
Within ±0.2 mg/dL from zero to 30 mg/dL
(straight-line method)
Repeatability:
Within ± 0.2 mg/dL over entire range
Drift:
Zero:
Less than 0.2 mg/dL/hr after 30-minute
warm-up
Calibration:
Less than 0.2 mg/dL/24 hr after 30-minute
warm-up
Performance Over Operating Conditions
Hemolysis:
No interference from HbO
2
levels up to
600 mg/dL
Turbidity:
Negligible interference from turbidity
associated with triglyceride (TGL) levels
up to 500 mg/dL
Operating Conditions
Temperature:
15°C to 32°C (59°F to 90°F)
Room Humidity:
5 to 80% relative humidity;
(non-condensing)
Storage Temperature:
-40°C to +70°C
(-40°F to +160°F)
Test Time:
Instantaneous for TOTAL Bilirubin, 2
minutes for DIRECT Bilirubin
Dimensions
inches centimeters
Width:
11
28
Depth:
13
33
Height:
7
18
Weight
pounds kilograms
Net:
9
4
Shipping:
12
5.5
Warranty:
One-year limited warranty on work-
manship and all parts except glass,
plastic and parts warranted by their
makers.
Certification:
Refer to Regulatory Notices (see page 11) for appli-
cable standards.
*CE marking only available on units delivered prior
to July 22, 2016.
1Reference Conditions: 20 to 25°C (68 to 77°F); 40 to 60% Relative Humidity; tolerances of reference or calibration
solutions excluded.
*
Содержание Bilirubin Stat-Analyzer BR2
Страница 2: ......
Страница 4: ...4 The Advanced Model BR2 Service Manual Notes...
Страница 5: ...1 Introduction...
Страница 6: ......
Страница 13: ...2 General Overview...
Страница 14: ......
Страница 22: ...22 The Advanced Model BR2 Service Manual Notes...
Страница 23: ...3 Maintenance...
Страница 24: ......
Страница 26: ...Notes...
Страница 27: ...4 Troubleshooting...
Страница 28: ......
Страница 30: ...30 The Advanced Model BR2 Service Manual Notes...
Страница 34: ...34 The Advanced Model BR2 Service Manual Notes...
Страница 35: ...5 Adjustments...
Страница 36: ......
Страница 41: ...6 Replacement Instructions...
Страница 42: ......
Страница 48: ......
Страница 49: ...7 Schematics...
Страница 50: ......
Страница 54: ...Appendix A Symbol Definitions...
Страница 55: ......
Страница 58: ...Appendix B Product Disposal and Recycling...
Страница 59: ......
Страница 61: ...Notes The Advanced Model BR2 Service Manual...
Страница 62: ...Appendix C Service Log...
Страница 63: ......
Страница 65: ...Symptoms Repairs Replacements or Problems or Changes Serviced by The Advanced Model BR2 Service Manual...
Страница 66: ...Index...
Страница 67: ......
Страница 69: ...Notes The Advanced Model BR2 Service Manual...