Document # E.0015.16.05 396194
IntegrAlarm USER AND INSTALLER MANUAL
5-FUNCTION KEYFOB
IntegrAlarm MODEL IA-FOB-1
February 09, 2004
Страница 1: ...Document E 0015 16 05 396194 IntegrAlarm USER AND INSTALLER MANUAL 5 FUNCTION KEYFOB IntegrAlarm MODEL IA FOB 1 February 09 2004 ...
Страница 2: ... E 0015 16 05 396194 Table of Contents 1 IntegrAlarm Overview 3 2 5 Function Keyfob Remote Control Unit 5 2 1 Description 5 2 2 Technical Specifications 5 2 3 Installation 6 2 3 1 Registration 6 2 3 2 Testing 6 ...
Страница 3: ...ization signal transmitted by the system Control Panel to the various peripherals every 3 minutes The system operates on 56 pseudo random selected channels In its present configuration the system includes five types of peripheral units Door window sensor PIR sensor Smoke detector 5 function keyfob handheld remote control unit Remote siren This manual is devoted to the installation instructions for...
Страница 4: ... Reorient or relocate the receiving antenna b Increase the separation between the equipment and receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the dealer or an experienced radio technician FCC ID RUF150702 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...
Страница 5: ...ications Operating frequency band ISM 902 928 MHz Mode of operation frequency hopping every data packet is transmitted on a different pseudo random selected frequency Data packet transmission duration less than 7 milliseconds Data packet validity check CRC Transmission and reception verification two way communication each received packet is acknowledged with an automatic repeat request ARQ in case...
Страница 6: ...show ZONE NOT FOUND If Control Panel identifies the remote control Control Panel will emit an audible beep and screen will show S N XXXXXX TYPE YYYY where XXXXX is the multifunction keyfob serial number and YYYY is REMOTE Ensure that the serial number displayed corresponds to the serial number of the multifunction keyfob and press OK at left of Control Panel Screen will show ACCEPT ZONE DATA NO YE...
Страница 7: ...ng Station and inform the operator that the PANIC function is about to be tested Note If you do not do this the police or security services will be called Now standing near the Control Panel press PANIC Ensure that the LED first flashes red indicating transmission to the Control Panel and then green indicating receipt of ACK response from the Control Panel Telephone the IntegrAlarm Monitoring Stat...
Страница 8: ...Document E 0015 16 05 396194 ...