Document: #HT000129 

Document Title: Calibrate Thermocouple 

Product(s): T-375 

Procedure: 

To calibrate a thermocouple after replacement or repair, it is necessary to have 
exterior temperature sensor (Fluke Thermocouple Thermometer 51/52 Series II or 
equivalent) in order to compare and adjust the temperature readings.  

Set the thermometer to the same scale as the Bagger (°F or °C). 

Place the temperature sensor probe from the Fluke or equivalent thermometer in 
contact with the 

Heater Bar

 as close to the point of contact for the 

Thermocouple 

Wire

 as possible. 

Access the 

Temperature Calibration Screen

, by starting at the 

Main Menu

proceeding to the 

Technical Assistance

 and 

Bagger Factory Screens

 

 

Press 

Temperature Calibration

 button on right side of 

Bagger Factory Settings

 

screen. 

 

 