A.3 Configure Your Network Interface (continued)
If your present address in not in the 192.168.0.xxx range, type in ‘ncpa.cpl’ at the command prompt and hit
[Enter] on the keyboard.
For Windows 7, this open the
Network Connections
window. Double click on the appropriate interface.
In the window that opens, select “Internet Protocol Version 4 (TCP/IP v4)” from the list and then click
on the [Properties] button.
For Windows 8 and 10, this open the Network Connections window. Double click on the appropriate
interface. In the window that opens, select “Internet Protocol Version 4 (TCP/IP v4)” from the list and
then click on the [Properties] button.
Set the address and subnet mask to appropriate values. (192.168.0.1 and 255.255.255.0 will work for an
SMD23E2 or SMD24E2 that has factory default settings.) The default gateway and DNS server settings can
be ignored.
A.4 Test Your Network Interface
Going back to the terminal you opened in the last step, type in ‘ping aaa.bbb.ccc.ddd’ where
‘aaa.bbb.ccc.ddd’ in the IP address of the SMD23E2 or SMD24E2. The computer will ping the unit and the
message “Reply from aaa.bbb.ccc.ddd: bytes=32 time<10ms TTL=128” should appear four times.
If the message “Request timed out.” or “Destination host unreachable” appears, then one of four things has
occurred:
You set a new IP address, but have not yet cycled power to the SMD23E2 or SMD24E2
You did not enter the correct address in the ping command.
The IP address of the SMD23E2 or SMD24E2 is not set correctly.
The SMD23E2 or SMD24E2 and the computer are not on the same subnet.
Содержание SMD23E2
Страница 10: ...ABOUT THIS MANUAL SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 10 Notes ...
Страница 42: ...MOTION CONTROL SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 42 Notes ...
Страница 52: ...CALCULATING MOVE PROFILES SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 52 Notes ...
Страница 66: ...CONFIGURATION MODE DATA FORMAT SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 66 Notes ...
Страница 94: ...INSTALLING THE SMD23E2 OR SMD24E2 SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 94 Notes ...
Страница 102: ...SET THE IP ADDRESS AND PROTOCOL SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 102 Notes ...
Страница 118: ...ETHERNET IP EXPLICIT MESSAGING SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 118 Notes ...
Страница 122: ...MODBUS TCP CONFIGURATION SMD23E2 and SMD24E2 User s Manual ADVANCED MICRO CONTROLS INC 122 Notes ...
Страница 132: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ...